Integer value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)
Parsed from file gdc7001.mib.txt
Company: None
Module: GDCMP7001-MIB
Integer value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)
Parsed from file GDCMP7001-MIB.mib
Module: GDCMP7001-MIB
mp7001MaintenanceLineIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)" ::= { mp7001MaintenanceEntry 1 }
Vendor: General DataComm, Inc.
Module: GDCMP7001-MIB
[Automatically extracted from oidview.com]
mp7001MaintenanceLineIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)" ::= { mp7001MaintenanceEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.6.10.2.1.1.2 | mp7001SoftReset | 0 | 0 | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose … |
1.3.6.1.4.1.498.6.10.2.1.1.3 | mp7001SysUpTime | 0 | 0 | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to … |
1.3.6.1.4.1.498.6.10.2.1.1.4 | mp7001DefaultInit | 0 | 0 | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefau… |
1.3.6.1.4.1.498.6.10.2.1.1.5 | mp7001ResetStats | 0 | 0 | Supports the action of soft resetting the mp7001ValidIntervals object. When this object is set to reset(2), then the unit will r… |
1.3.6.1.4.1.498.6.10.2.1.1.6 | mp7001LedStatus | 0 | 0 | Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit… |
1.3.6.1.4.1.498.6.10.2.1.1.7 | mp7001T1CircuitName | 0 | 0 | Circuit name T1 is connected to. |
1.3.6.1.4.1.498.6.10.2.1.1.8 | mp7001SetRealTime | 0 | 0 | Number of seconds from midnight Dec 31, 1969. |
1.3.6.1.4.1.498.6.10.2.1.1.9 | mp7001AlarmStatus | 0 | 0 | Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NTWK LOS bit 5 - NTWK LOF bit 4 - NWTK_AIS bit 3 - future use bi… |
1.3.6.1.4.1.498.6.10.2.1.1.10 | mp7001SystemTimingGenStatus | 0 | 0 | Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz… |
1.3.6.1.4.1.498.6.10.2.1.1.11 | mp7001StatLastInitialized | 0 | 0 | Number of seconds from midnight Dec 31, 1969 up until mp7001ValidIntervals was last initialized to zero |
1.3.6.1.4.1.498.6.10.2.1.1.12 | mp7001ValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought o… |