This is used to allow the NonVolatile Configuration to
be set to a factory default state. When this value is set to
factoryDefault(2) the unit will perform a reset to make
the default configuration take affect.
The value of normal(1) will be returned when the initialization
is complete.
The value of normal(1) can not be set by management.
Parsed from file gdc7001.mib.txt
Company: None
Module: GDCMP7001-MIB
This is used to allow the NonVolatile Configuration to
be set to a factory default state. When this value is set to
factoryDefault(2) the unit will perform a reset to make
the default configuration take affect.
The value of normal(1) will be returned when the initialization
is complete.
The value of normal(1) can not be set by management.
Parsed from file GDCMP7001-MIB.mib
Module: GDCMP7001-MIB
mp7001DefaultInit OBJECT-TYPE SYNTAX INTEGER { normal(1), factoryDefault(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(2) the unit will perform a reset to make the default configuration take affect. The value of normal(1) will be returned when the initialization is complete. The value of normal(1) can not be set by management." ::= { mp7001MaintenanceEntry 4 }
Vendor: General DataComm, Inc.
Module: GDCMP7001-MIB
[Automatically extracted from oidview.com]
mp7001DefaultInit OBJECT-TYPE SYNTAX INTEGER { normal(1), factoryDefault(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(2) the unit will perform a reset to make the default configuration take affect. The value of normal(1) will be returned when the initialization is complete. The value of normal(1) can not be set by management." ::= { mp7001MaintenanceEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.6.10.2.1.1.1 | mp7001MaintenanceLineIndex | 0 | 0 | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where… |
1.3.6.1.4.1.498.6.10.2.1.1.2 | mp7001SoftReset | 0 | 0 | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose … |
1.3.6.1.4.1.498.6.10.2.1.1.3 | mp7001SysUpTime | 0 | 0 | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to … |
1.3.6.1.4.1.498.6.10.2.1.1.5 | mp7001ResetStats | 0 | 0 | Supports the action of soft resetting the mp7001ValidIntervals object. When this object is set to reset(2), then the unit will r… |
1.3.6.1.4.1.498.6.10.2.1.1.6 | mp7001LedStatus | 0 | 0 | Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit… |
1.3.6.1.4.1.498.6.10.2.1.1.7 | mp7001T1CircuitName | 0 | 0 | Circuit name T1 is connected to. |
1.3.6.1.4.1.498.6.10.2.1.1.8 | mp7001SetRealTime | 0 | 0 | Number of seconds from midnight Dec 31, 1969. |
1.3.6.1.4.1.498.6.10.2.1.1.9 | mp7001AlarmStatus | 0 | 0 | Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NTWK LOS bit 5 - NTWK LOF bit 4 - NWTK_AIS bit 3 - future use bi… |
1.3.6.1.4.1.498.6.10.2.1.1.10 | mp7001SystemTimingGenStatus | 0 | 0 | Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz… |
1.3.6.1.4.1.498.6.10.2.1.1.11 | mp7001StatLastInitialized | 0 | 0 | Number of seconds from midnight Dec 31, 1969 up until mp7001ValidIntervals was last initialized to zero |
1.3.6.1.4.1.498.6.10.2.1.1.12 | mp7001ValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought o… |