This variable is used to report the elapsed system tick
time for conversion to real time at the controller and is
not related to the sysUpTime referenced in MIB-II.
Upon power-up of the unit, the elapsed time is cleared.
The elapsed time counter rolls over upon reaching the
maximum count.
Parsed from file gdc7001.mib.txt
Company: None
Module: GDCMP7001-MIB
This variable is used to report the elapsed system tick
time for conversion to real time at the controller and is
not related to the sysUpTime referenced in MIB-II.
Upon power-up of the unit, the elapsed time is cleared.
The elapsed time counter rolls over upon reaching the
maximum count.
Parsed from file GDCMP7001-MIB.mib
Module: GDCMP7001-MIB
mp7001SysUpTime OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count." ::= { mp7001MaintenanceEntry 3 }
Vendor: General DataComm, Inc.
Module: GDCMP7001-MIB
[Automatically extracted from oidview.com]
mp7001SysUpTime OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count." ::= { mp7001MaintenanceEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.6.10.2.1.1.1 | mp7001MaintenanceLineIndex | 0 | 0 | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where… |
1.3.6.1.4.1.498.6.10.2.1.1.2 | mp7001SoftReset | 0 | 0 | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose … |
1.3.6.1.4.1.498.6.10.2.1.1.4 | mp7001DefaultInit | 0 | 0 | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefau… |
1.3.6.1.4.1.498.6.10.2.1.1.5 | mp7001ResetStats | 0 | 0 | Supports the action of soft resetting the mp7001ValidIntervals object. When this object is set to reset(2), then the unit will r… |
1.3.6.1.4.1.498.6.10.2.1.1.6 | mp7001LedStatus | 0 | 0 | Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit… |
1.3.6.1.4.1.498.6.10.2.1.1.7 | mp7001T1CircuitName | 0 | 0 | Circuit name T1 is connected to. |
1.3.6.1.4.1.498.6.10.2.1.1.8 | mp7001SetRealTime | 0 | 0 | Number of seconds from midnight Dec 31, 1969. |
1.3.6.1.4.1.498.6.10.2.1.1.9 | mp7001AlarmStatus | 0 | 0 | Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NTWK LOS bit 5 - NTWK LOF bit 4 - NWTK_AIS bit 3 - future use bi… |
1.3.6.1.4.1.498.6.10.2.1.1.10 | mp7001SystemTimingGenStatus | 0 | 0 | Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz… |
1.3.6.1.4.1.498.6.10.2.1.1.11 | mp7001StatLastInitialized | 0 | 0 | Number of seconds from midnight Dec 31, 1969 up until mp7001ValidIntervals was last initialized to zero |
1.3.6.1.4.1.498.6.10.2.1.1.12 | mp7001ValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought o… |