The NMS510 Unit Configuration table entry. The information in this
entry augments the information in the corresponding entry in the
GDC SC Unit Configuration table and provides unit level configuration
for the installed NMS510.
Parsed from file nms510.mib.txt
Company: None
Module: NMS510-MIB
The NMS510 Unit Configuration table entry. The information in this
entry augments the information in the corresponding entry in the
GDC SC Unit Configuration table and provides unit level configuration
for the installed NMS510.
Parsed from file NMS510-MIB.mib
Module: NMS510-MIB
nms510UnitCfgEntry OBJECT-TYPE SYNTAX Nms510UnitCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The NMS510 Unit Configuration table entry. The information in this entry augments the information in the corresponding entry in the GDC SC Unit Configuration table and provides unit level configuration for the installed NMS510." INDEX { nms510UnitCfgIndex } ::= { nms510UnitCfgTable 1 }
Vendor: General DataComm, Inc.
Module: NMS510-MIB
[Automatically extracted from oidview.com]
nms510UnitCfgEntry OBJECT-TYPE SYNTAX Nms510UnitCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The NMS510 Unit Configuration table entry. The information in this entry augments the information in the corresponding entry in the GDC SC Unit Configuration table and provides unit level configuration for the installed NMS510." INDEX { nms510UnitCfgIndex } ::= { nms510UnitCfgTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.8.6.2.1.1 | nms510UnitCfgIndex | 0 | 0 | The index value which uniquely identifies the NMS510 to which this entry is applicable. This has the form of a SCinstance which … |
1.3.6.1.4.1.498.8.6.2.1.2 | nms510DteCtsDelay | 0 | 0 | RTS/CTS Delay options ctsOn(1) Forces both RTS and CTS On regardless of the state of the attached business equipment (the transmi… |
1.3.6.1.4.1.498.8.6.2.1.3 | nms510DteCtsDelayExt | 0 | 0 | RTS/CTS Delay options extension ext0mSec(1) Used to enable options cts0mSec(2) or ctsFix3Char(3) from MIB object nms510DteCtsDelay… |
1.3.6.1.4.1.498.8.6.2.1.4 | nms510FirmwareLevel | 0 | 0 | None |
1.3.6.1.4.1.498.8.6.2.1.5 | nms510AlarmCfgCountWindow | 0 | 0 | The DDS Alarm Threshold Alarm Interval. It specifies the amount of time in minutes, 1 to 15 minutes, in which the threshold sett… |
1.3.6.1.4.1.498.8.6.2.1.6 | nms510SoftReset | 0 | 0 | This object will cause software reset in dataset. |
1.3.6.1.4.1.498.8.6.2.1.7 | nms510FrontPanelInhibit | 0 | 0 | Inhibits front panel test switch. If a test switch is activated while inhibited it will simply be ignored. If enabled via the nm… |
1.3.6.1.4.1.498.8.6.2.1.8 | nms510FrontPanelEnable | 0 | 0 | Enables front panel test switch. If a test switch is activated while inhibited, via the nms510FrontPanelInhibit object, it will … |
1.3.6.1.4.1.498.8.6.2.1.9 | nms510HdlcInvert | 0 | 0 | Primary data invert option. Will enhance the quality of data when network does not provide B8Z5. Primarily used with DDS II 56k |
1.3.6.1.4.1.498.8.6.2.1.10 | nms510PiggyBackDetect | 0 | 0 | If set to 2 then either a Data Rate Adadaptor or 530 card is installed. |
1.3.6.1.4.1.498.8.6.2.1.11 | nms510ExtPortCtrlOut1 | 0 | 0 | This option sets the external output state (on/off) of the current network element and displays the external output. |
1.3.6.1.4.1.498.8.6.2.1.12 | nms510ExtPortCtrlOut2 | 0 | 0 | This option sets the external output state (on/off) of the current network element and displays the external output. |