Reference record for OID 1.3.6.1.4.1.498.8.6.2.1.12



parent
1.3.6.1.4.1.498.8.6.2.1 (nms510UnitCfgEntry)
node code
12
node name
nms510ExtPortCtrlOut2
dot oid
1.3.6.1.4.1.498.8.6.2.1.12
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) dsu(8) nms510(6) nms510UnitCfgTable(2) nms510UnitCfgEntry(1) nms510ExtPortCtrlOut2(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) dsu(8) nms510(6) nms510UnitCfgTable(2) nms510UnitCfgEntry(1) nms510ExtPortCtrlOut2(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) dsu(8) nms510(6) nms510UnitCfgTable(2) nms510UnitCfgEntry(1) nms510ExtPortCtrlOut2(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) dsu(8) nms510(6) nms510UnitCfgTable(2) nms510UnitCfgEntry(1) nms510ExtPortCtrlOut2(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) dsu(8) nms510(6) nms510UnitCfgTable(2) nms510UnitCfgEntry(1) nms510ExtPortCtrlOut2(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) dsu(8) nms510(6) nms510UnitCfgTable(2) nms510UnitCfgEntry(1) nms510ExtPortCtrlOut2(12)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/gdc/dsu/nms510/nms510UnitCfgTable/nms510UnitCfgEntry/nms510ExtPortCtrlOut2
  • /iso/identified-organization/dod/internet/private/enterprises/gdc/dsu/nms510/nms510UnitCfgTable/nms510UnitCfgEntry/nms510ExtPortCtrlOut2
  • /iso/org/dod/internet/private/enterprise/gdc/dsu/nms510/nms510UnitCfgTable/nms510UnitCfgEntry/nms510ExtPortCtrlOut2
  • /iso/org/dod/internet/private/enterprises/gdc/dsu/nms510/nms510UnitCfgTable/nms510UnitCfgEntry/nms510ExtPortCtrlOut2
  • /iso/iso-identified-organization/dod/internet/private/enterprise/gdc/dsu/nms510/nms510UnitCfgTable/nms510UnitCfgEntry/nms510ExtPortCtrlOut2
  • /iso/iso-identified-organization/dod/internet/private/enterprises/gdc/dsu/nms510/nms510UnitCfgTable/nms510UnitCfgEntry/nms510ExtPortCtrlOut2
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/498/8/6/2/1/12

    Description by mibdepot

    This option sets the external output state (on/off) of the
    current network element and displays the external output.

    Parsed from file nms510.mib.txt
    Company: None
    Module: NMS510-MIB

    Description by circitor

    This option sets the external output state (on/off) of the
    current network element and displays the external output.

    Parsed from file NMS510-MIB.mib
    Module: NMS510-MIB

    Information by mibdepot

    nms510ExtPortCtrlOut2 OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This option sets the external output state (on/off) of the current network element and displays the external output." ::= { nms510UnitCfgEntry 12 }

    Information by oid_info

    Vendor: General DataComm, Inc.
    Module: NMS510-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    nms510ExtPortCtrlOut2 OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This option sets the external output state (on/off) of the current network element and displays the external output." ::= { nms510UnitCfgEntry 12 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.498)

    Meltzer William

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.498.8.6.2.1.1 nms510UnitCfgIndex 0 0 The index value which uniquely identifies the NMS510 to which
    this entry is applicable. This has the form of a SCinstance
    which …
    1.3.6.1.4.1.498.8.6.2.1.2 nms510DteCtsDelay 0 0 RTS/CTS Delay options

    ctsOn(1) Forces both RTS and CTS On regardless of the
    state of the attached business equipment (the
    transmi…
    1.3.6.1.4.1.498.8.6.2.1.3 nms510DteCtsDelayExt 0 0 RTS/CTS Delay options extension

    ext0mSec(1) Used to enable options cts0mSec(2) or
    ctsFix3Char(3) from MIB object
    nms510DteCtsDelay…
    1.3.6.1.4.1.498.8.6.2.1.4 nms510FirmwareLevel 0 0 None
    1.3.6.1.4.1.498.8.6.2.1.5 nms510AlarmCfgCountWindow 0 0 The DDS Alarm Threshold Alarm Interval. It specifies the amount of
    time in minutes, 1 to 15 minutes, in which the threshold sett…
    1.3.6.1.4.1.498.8.6.2.1.6 nms510SoftReset 0 0 This object will cause software reset in dataset.
    1.3.6.1.4.1.498.8.6.2.1.7 nms510FrontPanelInhibit 0 0 Inhibits front panel test switch. If a test
    switch is activated while inhibited it will simply be ignored.
    If enabled via the nm…
    1.3.6.1.4.1.498.8.6.2.1.8 nms510FrontPanelEnable 0 0 Enables front panel test switch. If a test
    switch is activated while inhibited, via the
    nms510FrontPanelInhibit object, it will …
    1.3.6.1.4.1.498.8.6.2.1.9 nms510HdlcInvert 0 0 Primary data invert option. Will enhance the quality of
    data when network does not provide B8Z5. Primarily used
    with DDS II 56k
    1.3.6.1.4.1.498.8.6.2.1.10 nms510PiggyBackDetect 0 0 If set to 2 then either a Data Rate Adadaptor or 530 card is
    installed.
    1.3.6.1.4.1.498.8.6.2.1.11 nms510ExtPortCtrlOut1 0 0 This option sets the external output state (on/off) of the
    current network element and displays the external output.