svcAutoCallRetry is used only for switched calls, in which case the
attribute type is set to switched. Otherwise, this attribute is ignored
by the Vcs.
This attribute, if set to yes for Svc, indicates that the Vc will
continually try to establish the SVC rather than clearing the Vc after
the first unsuccessful call attempt. Further, if the call fails while in
data transfer phase, then the Vc will automatically attempt to
reconnect. The call attempts are made by the Vc once per time
provisioned in InterfaceOptions as callRetryTimer, repeatedly. If set
to no for SVCs, then the Vc behaves in the standard mode, making a
single call attempt.
Parsed from file nortelPP-vcTesterV1_BG00S4C.mib.txt
Company: None
Module: Nortel-Magellan-Passport-VcTesterMIB
svcAutoCallRetry is used only for switched calls, in which case the
attribute type is set to switched. Otherwise, this attribute is ignored
by the Vcs.
This attribute, if set to yes for Svc, indicates that the Vc will
continually try to establish the SVC rather than clearing the Vc after
the first unsuccessful call attempt. Further, if the call fails while in
data transfer phase, then the Vc will automatically attempt to
reconnect. The call attempts are made by the Vc once per time
provisioned in InterfaceOptions as callRetryTimer, repeatedly. If set
to no for SVCs, then the Vc behaves in the standard mode, making a
single call attempt.
Parsed from file Nortel-Magellan-Passport-VcTesterMIB.mib
Module: Nortel-Magellan-Passport-VcTesterMIB
Vendor: Northern Telecom, Ltd.
Module: Nortel-Magellan-Passport-VcTesterMIB
[Automatically extracted from oidview.com]
vctDcSvcAutoCallRetry OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-write STATUS mandatory DESCRIPTION "svcAutoCallRetry is used only for switched calls, in which case the attribute type is set to switched. Otherwise, this attribute is ignored by the Vcs. This attribute, if set to yes for Svc, indicates that the Vc will continually try to establish the SVC rather than clearing the Vc after the first unsuccessful call attempt. Further, if the call fails while in data transfer phase, then the Vc will automatically attempt to reconnect. The call attempts are made by the Vc once per time provisioned in InterfaceOptions as callRetryTimer, repeatedly. If set to no for SVCs, then the Vc behaves in the standard mode, making a single call attempt." DEFVAL { no } ::= { vctDcOptionsEntry 7 }
vctDcSvcAutoCallRetry OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-write STATUS mandatory DESCRIPTION "svcAutoCallRetry is used only for switched calls, in which case the attribute type is set to switched. Otherwise, this attribute is ignored by the Vcs. This attribute, if set to yes for Svc, indicates that the Vc will continually try to establish the SVC rather than clearing the Vc after the first unsuccessful call attempt. Further, if the call fails while in data transfer phase, then the Vc will automatically attempt to reconnect. The call attempts are made by the Vc once per time provisioned in InterfaceOptions as callRetryTimer, repeatedly. If set to no for SVCs, then the Vc behaves in the standard mode, making a single call attempt." DEFVAL { no } ::= { vctDcOptionsEntry 7 }
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.1 | vctDcLocalNpi | 0 | 0 | This attribute specifies the Numbering Plan Indicator (NPI) of the localDna. |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.2 | vctDcLocalDna | 0 | 0 | This attribute specifies the Data Network Address (Dna) of the local DTE. This address is used in formatting of call request to r… |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.3 | vctDcRemoteNpi | 0 | 0 | Remote numbering Plan Indicator (Npi) indicates the numbering plan used in the remoteDna. |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.4 | vctDcRemoteDna | 0 | 0 | This attribute specifies the Data Network Address (Dna) of the remote. This is the called (destination) DTE address (Dna) to whi… |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.5 | vctDcRemoteLcn | 0 | 0 | This attribute provides the remote LCN (Logical Channel Number) - it is used only for PVCs, where attribute type is set to perman… |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.6 | vctDcType | 0 | 0 | This attribute specifies the type of Vc call: switched, permanentMaster, permanentSlave, permanentSlaveWithBackup, permanentBackupSl… |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.8 | vctDcUserData | 0 | 0 | This attribute contains the user data, if present. userData is a 0 to 16 length string which is appended to the call request pac… |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.10 | vctDcDiscardPriority | 0 | 0 | This attribute specifies the discard priority for outgoing call using this DLCI. The discard priority has three provisioning val… |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.11 | vctDcDataPath | 0 | 0 | This attribute specifies the data path to be used by Virtual Circuits on this interface. The value of the dataPath attribute in … |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.13 | vctDcCugIndex | 0 | 0 | This attribute specifies the CUG index which is to be signalled in PVC call requests to the remote end. The type of CUG signalli… |
| 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.14 | vctDcCugType | 0 | 0 | This attribute specifies the type of CUG signalling to be used in PVC call request. Index of CUG to be used is defined in attrib… |