Reference record for OID 1.3.6.1.4.1.818.1.1.16.8.2



parent
1.3.6.1.4.1.818.1.1.16.8 (upsControl_sixth)
node code
2
node name
upsShutdownAfterDelay_sixth
dot oid
1.3.6.1.4.1.818.1.1.16.8.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geSixthUPS(16) upsControl_sixth(8) upsShutdownAfterDelay_sixth(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geSixthUPS(16) upsControl_sixth(8) upsShutdownAfterDelay_sixth(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geSixthUPS(16) upsControl_sixth(8) upsShutdownAfterDelay_sixth(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geSixthUPS(16) upsControl_sixth(8) upsShutdownAfterDelay_sixth(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geSixthUPS(16) upsControl_sixth(8) upsShutdownAfterDelay_sixth(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geSixthUPS(16) upsControl_sixth(8) upsShutdownAfterDelay_sixth(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geSixthUPS/upsControl_sixth/upsShutdownAfterDelay_sixth
  • /iso/identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geSixthUPS/upsControl_sixth/upsShutdownAfterDelay_sixth
  • /iso/org/dod/internet/private/enterprise/imv/geHardware/geUPS/geSixthUPS/upsControl_sixth/upsShutdownAfterDelay_sixth
  • /iso/org/dod/internet/private/enterprises/imv/geHardware/geUPS/geSixthUPS/upsControl_sixth/upsShutdownAfterDelay_sixth
  • /iso/iso-identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geSixthUPS/upsControl_sixth/upsShutdownAfterDelay_sixth
  • /iso/iso-identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geSixthUPS/upsControl_sixth/upsShutdownAfterDelay_sixth
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/818/1/1/16/8/2

    Description by mibdepot

    Setting this object will shutdown (i.e., turn off)
    either the UPS output or the UPS system (as determined
    by the value of upsShutdownType at the time of
    shutdown) after the indicated number of seconds, or
    less if the UPS batteries become depleted. Setting
    this object to 0 will cause the shutdown to occur
    immediately. Setting this object to -1 will abort the
    countdown. If the system is already in the desired
    state at the time the countdown reaches 0, then
    nothing will happen. That is, there is no additional
    action at that time if upsShutdownType = system and
    the system is already off. Similarly, there is no
    additional action at that time if upsShutdownType =
    output and the output is already off. When read,
    upsShutdownAfterDelay will return the number of
    seconds remaining until shutdown, or -1 if no shutdown
    countdown is in effect. On some systems, if the agent
    is restarted while a shutdown countdown is in effect,
    the countdown may be aborted. Sets to this object
    override any upsShutdownAfterDelay already in effect.(*)

    Parsed from file GE_PARALLELUPS.mib.txt
    Company: ge
    Module: GE_PARALLELUPS

    Information by oid_info

    Vendor: IMV Victron bv
    Module: GE_PARALLELUPS

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsShutdownAfterDelay_sixth OBJECT-TYPE SYNTAX Integer32 (-1..2147483648) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*)" ::= { upsControl_sixth 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.818)

    Versteeg Theo

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.16.8.2.0 0 0 0 upsShutdownAfterDelay_sixth

    Brothers (12)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.16.8.1 upsShutdownType_sixth 1 1 This object determines the nature of the action to be
    taken at the time when the countdown of the
    upsShutdownAfterDelay and upsRe…
    1.3.6.1.4.1.818.1.1.16.8.3 upsStartupAfterDelay_sixth 1 1 Setting this object will start the output after the
    indicated number of seconds, including starting the
    UPS, if necessary. Setti…
    1.3.6.1.4.1.818.1.1.16.8.4 upsRebootWithDuration_sixth 1 1 Setting this object will immediately shutdown (i.e.,
    turn off) either the UPS output or the UPS system (as
    determined by the valu…
    1.3.6.1.4.1.818.1.1.16.8.5 upsAutoRestart_sixth 1 1 Setting this object to 'on' will cause the UPS system
    to restart after a shutdown if the shutdown occurred
    during a power loss as…
    1.3.6.1.4.1.818.1.1.16.8.6 upsReceptaclesNum_sixth 1 1 The number of receptacles utilized in this device.
    This entry indicates the number of rows in the receptacle
    table.
    1.3.6.1.4.1.818.1.1.16.8.7 upsReceptacleTable_sixth 1 3 A list of receptacle table entries. The number of
    entries is given by the value of upsReceptacleNum.
    1.3.6.1.4.1.818.1.1.16.8.8 upsUPSMode_sixth 1 1 The operation mode off the UPS. Off-line indicates a
    mode in which the input power is transferred to the
    output directly or via a…
    1.3.6.1.4.1.818.1.1.16.8.9 upsRectifierOnOff_sixth 1 1 The present state of the rectifier. Setting this
    object to 'on' will cause the rectifier to be turned
    on. Setting this object to …
    1.3.6.1.4.1.818.1.1.16.8.10 upsBatteryChargeMethod_sixth 1 1 The present state of the charge method. Setting this
    object to 'Normal charge' will cause the battery to be
    charged using the nor…
    1.3.6.1.4.1.818.1.1.16.8.11 upsInverterOnOff_sixth 1 1 The present state of the inverter. Setting this
    object to 'on' will cause the inverter to be turned
    on. Setting this object to 'o…
    1.3.6.1.4.1.818.1.1.16.8.12 upsBypassOnOff_sixth 1 1 The present state of the bypass. Setting this
    object to 'on' will cause the bypass to be activated.
    Setting this object to 'off' …
    1.3.6.1.4.1.818.1.1.16.8.13 upsLoadSource_sixth 1 1 The present source of the load. Setting this
    object to 'On bypass' will cause the load to be
    supplied by the bypass.
    Setting this …