Generally, individual devices in this MIB are
distinguished by BiaIndex and SlotIndex. This
device differs from many in that it contains
multiple subdevices (in this case, switch ports).
The number of subdevices varies with the manufactured
configuration. Subdevices within devices are indexed
by BiaIndex, SlotIndex, and SubDeviceIndex.
When the subdevice column is read from the table,
the value '1' is always returned.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cbftf150SubDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (in this case, switch ports). The number of subdevices varies with the manufactured configuration. Subdevices within devices are indexed by BiaIndex, SlotIndex, and SubDeviceIndex. When the subdevice column is read from the table, the value '1' is always returned." ::= { cbftf150Entry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.22.1.2 | cbftf150BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholde… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.3 | cbftf150SlotIndex | 0 | 0 | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices f… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.4 | cbftf150Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.5 | cbftf150MRevision | 0 | 0 | The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.6 | cbftf150CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.7 | cbftf150SerialNumber | 0 | 0 | The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that inde… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.8 | cbftf150ConfigMode | 0 | 0 | This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP man… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.9 | cbftf150FirmwareRevision | 0 | 0 | The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used fo… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.10 | cbftf150FormFactor | 0 | 0 | A code corresponding to a physical configuration of the product. This code indicates the number of slots occupied and the number … |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.11 | cbftf150AutoNegotTbl | 0 | 0 | Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. There are mul… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.12 | cbftf150FullDuplexTbl | 0 | 0 | In most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half dup… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.13 | cbftf150100MbpsTbl | 0 | 0 | In most cases this is a configuration setting that controls the link speed. On twisted pair ports with autonegotiation enabled, … |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.14 | cbftf150CrossTbl | 0 | 0 | Configuration setting for copper TX/RX pair correction. A setting of auto(1) causes the port to automatically correct TX/RX pairs… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.15 | cbftf150FarEndFaultTbl | 0 | 0 | When Far End Fault is set to enabled(1), a loss of link on receive will cause the transmitter to shut down, in order to inform th… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.16 | cbftf150ConnectorTbl | 0 | 0 | The style of connectors built into each port of this device. There are multiple subdevices in this table, numbering one entry pe… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.17 | cbftf150LinkTbl | 0 | 0 | This table contains the link status of each port in the switch. There are multiple subdevices in this table, numbering one entry… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.18 | cbftf150PortCount | 0 | 0 | A count of the switch ports in this device. i.e. the maximum subdevice index supported by this switch. |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.19 | cbftf150CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |