Reference record for OID 1.3.6.1.4.1.868.2.4.1.2.2.22.1.6



parent
1.3.6.1.4.1.868.2.4.1.2.2.22.1 (cbftf150Entry)
node code
6
node name
cbftf150CfgMatch
dot oid
1.3.6.1.4.1.868.2.4.1.2.2.22.1.6
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cbftf150Table(22) cbftf150Entry(1) cbftf150CfgMatch(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cbftf150Table(22) cbftf150Entry(1) cbftf150CfgMatch(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cbftf150Table(22) cbftf150Entry(1) cbftf150CfgMatch(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cbftf150Table(22) cbftf150Entry(1) cbftf150CfgMatch(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cbftf150Table(22) cbftf150Entry(1) cbftf150CfgMatch(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cbftf150Table(22) cbftf150Entry(1) cbftf150CfgMatch(6)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cbftf150Table/cbftf150Entry/cbftf150CfgMatch
  • /iso/identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cbftf150Table/cbftf150Entry/cbftf150CfgMatch
  • /iso/org/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cbftf150Table/cbftf150Entry/cbftf150CfgMatch
  • /iso/org/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cbftf150Table/cbftf150Entry/cbftf150CfgMatch
  • /iso/iso-identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cbftf150Table/cbftf150Entry/cbftf150CfgMatch
  • /iso/iso-identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cbftf150Table/cbftf150Entry/cbftf150CfgMatch
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/868/2/4/1/2/2/22/1/6

    Description by circitor

    yes(1) indicates that the conditions specified in
    cpsGroupCtrl.0 match the Groups value for this
    device. no(2) means that there is no match.
    notApplicable(3) indicates that cpsGroupCtrl.0 is null
    and therefore no comparison was performed.
    There are no subdevices for this value, so the
    placeholder value 1 is always used for that index.

    Parsed from file MCC16-MIB.mib
    Module: MCC16-MIB

    Information by oid_info

    Vendor: Transition Engineering Inc.
    Module: MCC16-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cbftf150CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cbftf150Entry 6 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.868)

    Trivedi Hemant

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.1 cbftf150SubDeviceIndex 0 0 Generally, individual devices in this MIB are
    distinguished by BiaIndex and SlotIndex. This
    device differs from many in that it c…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.2 cbftf150BiaIndex 0 0 The serial number (BIA) of the cabinet in which the
    device is installed.
    There are no subdevices for this value, so the
    placeholde…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.3 cbftf150SlotIndex 0 0 The slot in which the device is installed. Power Supplies
    occupy special slots numbered 125 and higher.
    There are no subdevices f…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.4 cbftf150Groups 0 0 User-defined keywords that group this device together with
    other devices under a user-defined scheme. By placing
    matching keyword…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.5 cbftf150MRevision 0 0 The marketing revision of this device.
    There are no subdevices for this value, so the
    placeholder value 1 is always used for that…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.7 cbftf150SerialNumber 0 0 The serial number of this device.
    There are no subdevices for this value, so the
    placeholder value 1 is always used for that inde…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.8 cbftf150ConfigMode 0 0 This device may have a jumper or switch that disables
    software management of the device. When ConfigMode is
    hardware(2), SNMP man…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.9 cbftf150FirmwareRevision 0 0 The firmware revision level for this device.
    There are no subdevices for this value, so the
    placeholder value 1 is always used fo…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.10 cbftf150FormFactor 0 0 A code corresponding to a physical configuration
    of the product. This code indicates the number of
    slots occupied and the number …
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.11 cbftf150AutoNegotTbl 0 0 Enables or disables autonegtiation of link speed and
    duplex for twisted pair ports. Not supported on Fiber
    ports. There are mul…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.12 cbftf150FullDuplexTbl 0 0 In most cases this is a configuration setting that
    controls the duplex mode; fullDuplex is full duplex and
    halfDuplex is half dup…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.13 cbftf150100MbpsTbl 0 0 In most cases this is a configuration setting that
    controls the link speed. On twisted pair ports with
    autonegotiation enabled, …
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.14 cbftf150CrossTbl 0 0 Configuration setting for copper TX/RX pair correction.
    A setting of auto(1) causes the port to automatically
    correct TX/RX pairs…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.15 cbftf150FarEndFaultTbl 0 0 When Far End Fault is set to enabled(1), a loss of
    link on receive will cause the transmitter to shut down,
    in order to inform th…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.16 cbftf150ConnectorTbl 0 0 The style of connectors built into each port of this
    device. There are multiple subdevices in this table,
    numbering one entry pe…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.17 cbftf150LinkTbl 0 0 This table contains the link status of each port in the
    switch. There are multiple subdevices in this table,
    numbering one entry…
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.18 cbftf150PortCount 0 0 A count of the switch ports in this device. i.e. the
    maximum subdevice index supported by this switch.
    1.3.6.1.4.1.868.2.4.1.2.2.22.1.19 cbftf150CacheClean 0 0 When the value is clean(1)Device and Management Module
    cache are synchronized, no automatic corrections to
    configuration will occ…