In most cases this is a configuration setting that
controls the duplex mode; fullDuplex is full duplex and
halfDuplex is half duplex. On twisted pair ports with
autonegotiation enabled, this is a status indication
showing the duplex value decided upon during the
negotiation. When link is down, autonegotiation has
not been completed yet, and the duplex setting is
therefore unknown and the value is negotiating(3).
There are multiple subdevices in this table, numbering
one entry per port.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cbftf150FullDuplexTbl OBJECT-TYPE SYNTAX INTEGER { fullDuplex(1), halfDuplex(2), negotiating(3) } ACCESS read-write STATUS mandatory DESCRIPTION "In most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports with autonegotiation enabled, this is a status indication showing the duplex value decided upon during the negotiation. When link is down, autonegotiation has not been completed yet, and the duplex setting is therefore unknown and the value is negotiating(3). There are multiple subdevices in this table, numbering one entry per port." ::= { cbftf150Entry 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.22.1.1 | cbftf150SubDeviceIndex | 0 | 0 | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it c… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.2 | cbftf150BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholde… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.3 | cbftf150SlotIndex | 0 | 0 | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices f… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.4 | cbftf150Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.5 | cbftf150MRevision | 0 | 0 | The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.6 | cbftf150CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.7 | cbftf150SerialNumber | 0 | 0 | The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that inde… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.8 | cbftf150ConfigMode | 0 | 0 | This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP man… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.9 | cbftf150FirmwareRevision | 0 | 0 | The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used fo… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.10 | cbftf150FormFactor | 0 | 0 | A code corresponding to a physical configuration of the product. This code indicates the number of slots occupied and the number … |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.11 | cbftf150AutoNegotTbl | 0 | 0 | Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. There are mul… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.13 | cbftf150100MbpsTbl | 0 | 0 | In most cases this is a configuration setting that controls the link speed. On twisted pair ports with autonegotiation enabled, … |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.14 | cbftf150CrossTbl | 0 | 0 | Configuration setting for copper TX/RX pair correction. A setting of auto(1) causes the port to automatically correct TX/RX pairs… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.15 | cbftf150FarEndFaultTbl | 0 | 0 | When Far End Fault is set to enabled(1), a loss of link on receive will cause the transmitter to shut down, in order to inform th… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.16 | cbftf150ConnectorTbl | 0 | 0 | The style of connectors built into each port of this device. There are multiple subdevices in this table, numbering one entry pe… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.17 | cbftf150LinkTbl | 0 | 0 | This table contains the link status of each port in the switch. There are multiple subdevices in this table, numbering one entry… |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.18 | cbftf150PortCount | 0 | 0 | A count of the switch ports in this device. i.e. the maximum subdevice index supported by this switch. |
1.3.6.1.4.1.868.2.4.1.2.2.22.1.19 | cbftf150CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |