This is a control variable.
It is written by an external management entity.
Changes take effect as soon as practical in the implementation.
This attribute, when set to intermediateMSTA (0), allows intermediate mesh STAs to respond with a PREP to a PREQ if they have valid forwarding information to the requested target. When set to targetOnly (1), only the target mesh STA is allowed to respond with a PREP to a PREQ.
Parsed from file 802_11mib.txt
Company: ieee
Module: IEEE802dot11-MIB
Vendor: IEEE
Module: IEEE802dot11-MIB (802_11mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
dot11MeshHWMPtargetOnly OBJECT-TYPE SYNTAX INTEGER { intermediateMSTA(0), targetOnly(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when set to intermediateMSTA (0), allows intermediate mesh STAs to respond with a PREP to a PREQ if they have valid forwarding information to the requested target. When set to targetOnly (1), only the target mesh STA is allowed to respond with a PREP to a PREQ." DEFVAL { targetOnly } ::= { dot11MeshHWMPConfigEntry 11}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.2.840.10036.1.24.1.1 | dot11MeshHWMPmaxPREQretries | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.2 | dot11MeshHWMPnetDiameter | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.3 | dot11MeshHWMPnetDiameterTraversalTime | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.4 | dot11MeshHWMPpreqMinInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.5 | dot11MeshHWMPperrMinInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.6 | dot11MeshHWMPactivePathToRootTimeout | 0 | 0 | dot11MeshHWMPactivePathtoRootTimeout |
1.2.840.10036.1.24.1.7 | dot11MeshHWMPactivePathTimeout | 0 | 0 | dot11MeshHWMPactivePathtimeout |
1.2.840.10036.1.24.1.8 | dot11MeshHWMProotMode | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.9 | dot11MeshHWMProotInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.10 | dot11MeshHWMPrannInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.12 | dot11MeshHWMPmaintenanceInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.13 | dot11MeshHWMPconfirmationInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |