This is a control variable.
It is written by an external management entity.
Changes take effect as soon as practical in the implementation.
This attribute controls the configuration of a mesh STA as root mesh STA. A mesh STA is configured as a root mesh STA if dot11MeshHWMProotMode is set to 2, 3 or 4. Different values correspond to different modes of the root mesh STA. The mesh STA is not a root mesh STA when the attribute is set to 0.
Parsed from file 802_11mib.txt
Company: ieee
Module: IEEE802dot11-MIB
Vendor: IEEE
Module: IEEE802dot11-MIB (802_11mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
dot11MeshHWMProotMode OBJECT-TYPE SYNTAX INTEGER { noRoot(0), proactivePREQnoPREP(2), proactivePREQwithPREP(3), rann(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute controls the configuration of a mesh STA as root mesh STA. A mesh STA is configured as a root mesh STA if dot11MeshHWMProotMode is set to 2, 3 or 4. Different values correspond to different modes of the root mesh STA. The mesh STA is not a root mesh STA when the attribute is set to 0." DEFVAL { noRoot } ::= { dot11MeshHWMPConfigEntry 8}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.2.840.10036.1.24.1.1 | dot11MeshHWMPmaxPREQretries | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.2 | dot11MeshHWMPnetDiameter | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.3 | dot11MeshHWMPnetDiameterTraversalTime | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.4 | dot11MeshHWMPpreqMinInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.5 | dot11MeshHWMPperrMinInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.6 | dot11MeshHWMPactivePathToRootTimeout | 0 | 0 | dot11MeshHWMPactivePathtoRootTimeout |
1.2.840.10036.1.24.1.7 | dot11MeshHWMPactivePathTimeout | 0 | 0 | dot11MeshHWMPactivePathtimeout |
1.2.840.10036.1.24.1.9 | dot11MeshHWMProotInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.10 | dot11MeshHWMPrannInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.11 | dot11MeshHWMPtargetOnly | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.12 | dot11MeshHWMPmaintenanceInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.13 | dot11MeshHWMPconfirmationInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |