dot11MeshHWMPactivePathtoRootTimeout
View at oid-info.com
This is a control variable.
It is written by an external management entity.
Changes take effect as soon as practical in the implementation.
This object shall specify the time (in TUs) for which mesh STAs receiving a proactive PREQ shall consider the forwarding information to the root mesh STA to be valid; it needs to be greater than dot11MeshHWMProotInterval.
Parsed from file 802_11mib.txt
Company: ieee
Module: IEEE802dot11-MIB
Vendor: IEEE
Module: IEEE802dot11-MIB (802_11mib)
Type: TABULAR
Access: read-write
Syntax: Unsigned32
(
1..65535 )
Automatically extracted from www.mibdepot.com
dot11MeshHWMPactivePathToRootTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object shall specify the time (in TUs) for which mesh STAs receiving a proactive PREQ shall consider the forwarding information to the root mesh STA to be valid; it needs to be greater than dot11MeshHWMProotInterval." DEFVAL { 5000 } ::= { dot11MeshHWMPConfigEntry 6}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.2.840.10036.1.24.1.1 | dot11MeshHWMPmaxPREQretries | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.2 | dot11MeshHWMPnetDiameter | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.3 | dot11MeshHWMPnetDiameterTraversalTime | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.4 | dot11MeshHWMPpreqMinInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.5 | dot11MeshHWMPperrMinInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.7 | dot11MeshHWMPactivePathTimeout | 0 | 0 | dot11MeshHWMPactivePathtimeout |
1.2.840.10036.1.24.1.8 | dot11MeshHWMProotMode | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.9 | dot11MeshHWMProotInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.10 | dot11MeshHWMPrannInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.11 | dot11MeshHWMPtargetOnly | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.12 | dot11MeshHWMPmaintenanceInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |
1.2.840.10036.1.24.1.13 | dot11MeshHWMPconfirmationInterval | 0 | 0 | This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the imple… |