Reference record for OID 1.2.840.10036.2.4.1.2


parent
1.2.840.10036.2.4.1 (dot11EDCAEntry)
node code
2
node name
dot11EDCATableCWmin
dot oid
1.2.840.10036.2.4.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) member-body(2) us(840) ieee802dot11(10036) dot11mac(2) dot11EDCATable(4) dot11EDCAEntry(1) dot11EDCATableCWmin(2)}
  • iri oid
  • /iso/member-body/us/ieee802dot11/dot11mac/dot11EDCATable/dot11EDCAEntry/dot11EDCATableCWmin
  • iri by oid_info
    /ISO/Member-Body/US/10036/2/4/1/2

    Description by mibdepot

    This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect as soon as practical in the implementation.

    This attribute specifies the value of the minimum size of the window that is used by a STA for a particular AC for generating a random number for the backoff. The value of this attribute is such that it could always be expressed in the form of 2**X - 1, where X is an integer. The default value for this attribute is
    aCWmin, if dot11EDCATableIndex is 1 or 2.
    (aCWmin+1)/2 - 1, if dot11EDCATableIndex is 3.
    (aCWmin+1)/4 - 1, if dot11EDCATableIndex is 4.

    Parsed from file 802_11mib.txt
    Company: ieee
    Module: IEEE802dot11-MIB

    Information by oid_info

    Vendor: IEEE
    Module: IEEE802dot11-MIB (802_11mib)
    Type: TABULAR
    Access: read-only
    Syntax: Unsigned32
    (
    0..255 )

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    dot11EDCATableCWmin OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the minimum size of the window that is used by a STA for a particular AC for generating a random number for the backoff. The value of this attribute is such that it could always be expressed in the form of 2**X - 1, where X is an integer. The default value for this attribute is aCWmin, if dot11EDCATableIndex is 1 or 2. (aCWmin+1)/2 - 1, if dot11EDCATableIndex is 3. (aCWmin+1)/4 - 1, if dot11EDCATableIndex is 4." ::= { dot11EDCAEntry 2 }

    First Registration Authority (recovered by parent 1.2.840.10036)

    Vic Hayes

    Current Registration Authority (recovered by parent 1.2.840)

    Joyce Hsu

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.2.840.10036.2.4.1.1 dot11EDCATableIndex 0 0 The auxiliary variable used to identify instances of the columnar objects in the EDCA Table. The value of this variable is
    1, if…
    1.2.840.10036.2.4.1.3 dot11EDCATableCWmax 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.4 dot11EDCATableAIFSN 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.5 dot11EDCATableTXOPLimit 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.6 dot11EDCATableMSDULifetime 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.7 dot11EDCATableMandatory 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …