Reference record for OID 1.2.840.10036.2.4.1.7


parent
1.2.840.10036.2.4.1 (dot11EDCAEntry)
node code
7
node name
dot11EDCATableMandatory
dot oid
1.2.840.10036.2.4.1.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) member-body(2) us(840) ieee802dot11(10036) dot11mac(2) dot11EDCATable(4) dot11EDCAEntry(1) dot11EDCATableMandatory(7)}
  • iri oid
  • /iso/member-body/us/ieee802dot11/dot11mac/dot11EDCATable/dot11EDCAEntry/dot11EDCATableMandatory
  • iri by oid_info
    /ISO/Member-Body/US/10036/2/4/1/7

    Description by mibdepot

    This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect as soon as practical in the implementation.

    This attribute, when true, indicates that admission control is mandatory for the given AC. When false, this attribute indicates that the admission control is not mandatory for the given AC.

    Parsed from file 802_11mib.txt
    Company: ieee
    Module: IEEE802dot11-MIB

    Information by oid_info

    Vendor: IEEE
    Module: IEEE802dot11-MIB (802_11mib)
    Type: TABULAR
    Access: read-write
    Syntax: TruthValue

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    dot11EDCATableMandatory OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that admission control is mandatory for the given AC. When false, this attribute indicates that the admission control is not mandatory for the given AC." DEFVAL { false } ::= { dot11EDCAEntry 7 }

    First Registration Authority (recovered by parent 1.2.840.10036)

    Vic Hayes

    Current Registration Authority (recovered by parent 1.2.840)

    Joyce Hsu

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.2.840.10036.2.4.1.1 dot11EDCATableIndex 0 0 The auxiliary variable used to identify instances of the columnar objects in the EDCA Table. The value of this variable is
    1, if…
    1.2.840.10036.2.4.1.2 dot11EDCATableCWmin 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.3 dot11EDCATableCWmax 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.4 dot11EDCATableAIFSN 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.5 dot11EDCATableTXOPLimit 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.6 dot11EDCATableMSDULifetime 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.