This is a control variable.
It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
Changes take effect as soon as practical in the implementation.
This attribute specifies the maximum number of microseconds of an EDCA TXOP for a given AC. The default value for this attribute is
1) 0 for all PHYs, if dot11EDCATableIndex is 1 or 2; this implies that the sender can send one MSDU in an EDCA TXOP,
2) 3008 microseconds for Clause 18 and Clause 19 PHY and 6016 microseconds for Clause 17 PHY, if dot11EDCATableIndex is 3,
3) 1504 microseconds for Clause 18 and Clause 19) PHY and 3264 microseconds for Clause 17 PHY, if dot11EDCATableIndex is 4.
Parsed from file 802_11mib.txt
Company: ieee
Module: IEEE802dot11-MIB
Vendor: IEEE
Module: IEEE802dot11-MIB (802_11mib)
Type: TABULAR
Access: read-write
Syntax: Unsigned32
(
0..65535 )
Automatically extracted from www.mibdepot.com
dot11EDCATableTXOPLimit OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum number of microseconds of an EDCA TXOP for a given AC. The default value for this attribute is 1) 0 for all PHYs, if dot11EDCATableIndex is 1 or 2; this implies that the sender can send one MSDU in an EDCA TXOP, 2) 3008 microseconds for Clause 18 and Clause 19 PHY and 6016 microseconds for Clause 17 PHY, if dot11EDCATableIndex is 3, 3) 1504 microseconds for Clause 18 and Clause 19) PHY and 3264 microseconds for Clause 17 PHY, if dot11EDCATableIndex is 4." ::= { dot11EDCAEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.2.840.10036.2.4.1.1 | dot11EDCATableIndex | 0 | 0 | The auxiliary variable used to identify instances of the columnar objects in the EDCA Table. The value of this variable is 1, if… |
1.2.840.10036.2.4.1.2 | dot11EDCATableCWmin | 0 | 0 | This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect … |
1.2.840.10036.2.4.1.3 | dot11EDCATableCWmax | 0 | 0 | This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect … |
1.2.840.10036.2.4.1.4 | dot11EDCATableAIFSN | 0 | 0 | This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect … |
1.2.840.10036.2.4.1.6 | dot11EDCATableMSDULifetime | 0 | 0 | This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect … |
1.2.840.10036.2.4.1.7 | dot11EDCATableMandatory | 0 | 0 | This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect … |