Reference record for OID 1.2.840.10036.2.4.1.5


parent
1.2.840.10036.2.4.1 (dot11EDCAEntry)
node code
5
node name
dot11EDCATableTXOPLimit
dot oid
1.2.840.10036.2.4.1.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) member-body(2) us(840) ieee802dot11(10036) dot11mac(2) dot11EDCATable(4) dot11EDCAEntry(1) dot11EDCATableTXOPLimit(5)}
  • iri oid
  • /iso/member-body/us/ieee802dot11/dot11mac/dot11EDCATable/dot11EDCAEntry/dot11EDCATableTXOPLimit
  • iri by oid_info
    /ISO/Member-Body/US/10036/2/4/1/5

    Description by mibdepot

    This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect as soon as practical in the implementation.

    This attribute specifies the maximum number of microseconds of an EDCA TXOP for a given AC. The default value for this attribute is
    1) 0 for all PHYs, if dot11EDCATableIndex is 1 or 2; this implies that the sender can send one MSDU in an EDCA TXOP,
    2) 3008 microseconds for Clause 18 and Clause 19 PHY and 6016 microseconds for Clause 17 PHY, if dot11EDCATableIndex is 3,
    3) 1504 microseconds for Clause 18 and Clause 19) PHY and 3264 microseconds for Clause 17 PHY, if dot11EDCATableIndex is 4.

    Parsed from file 802_11mib.txt
    Company: ieee
    Module: IEEE802dot11-MIB

    Information by oid_info

    Vendor: IEEE
    Module: IEEE802dot11-MIB (802_11mib)
    Type: TABULAR
    Access: read-write
    Syntax: Unsigned32
    (
    0..65535 )

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    dot11EDCATableTXOPLimit OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum number of microseconds of an EDCA TXOP for a given AC. The default value for this attribute is 1) 0 for all PHYs, if dot11EDCATableIndex is 1 or 2; this implies that the sender can send one MSDU in an EDCA TXOP, 2) 3008 microseconds for Clause 18 and Clause 19 PHY and 6016 microseconds for Clause 17 PHY, if dot11EDCATableIndex is 3, 3) 1504 microseconds for Clause 18 and Clause 19) PHY and 3264 microseconds for Clause 17 PHY, if dot11EDCATableIndex is 4." ::= { dot11EDCAEntry 5 }

    First Registration Authority (recovered by parent 1.2.840.10036)

    Vic Hayes

    Current Registration Authority (recovered by parent 1.2.840)

    Joyce Hsu

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.2.840.10036.2.4.1.1 dot11EDCATableIndex 0 0 The auxiliary variable used to identify instances of the columnar objects in the EDCA Table. The value of this variable is
    1, if…
    1.2.840.10036.2.4.1.2 dot11EDCATableCWmin 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.3 dot11EDCATableCWmax 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.4 dot11EDCATableAIFSN 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.6 dot11EDCATableMSDULifetime 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …
    1.2.840.10036.2.4.1.7 dot11EDCATableMandatory 0 0 This is a control variable.
    It is written by the MAC upon receiving an EDCA Parameter Set in a Beacon frame.
    Changes take effect …