dot1dStpPortAdminPathCost OBJECT-TYPE
SYNTAX Integer32 (0..200000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administratively assigned value for the contribution
of this port to the path cost of paths toward the spanning
tree root.
Writing a value of \0\ assigns the automatically calculated
default Path Cost value to the port. If the default Path
Cost is being used, this object returns \0\ when read.
This complements the object dot1dStpPortPathCost or
dot1dStpPortPathCost32, which returns the operational value
of the path cost.
The value of this object MUST be retained across
reinitializations of the management system."
REFERENCE
"IEEE 802.1D-1998: Section 8.5.5.3"
View at oid-info.com
The administratively assigned value for the contribution
of this port to the path cost of paths toward the spanning
tree root.
Writing a value of '0' assigns the automatically calculated
default Path Cost value to the port. If the default Path
Cost is being used, this object returns '0' when read.
This complements the object dot1dStpPortPathCost or
dot1dStpPortPathCost32, which returns the operational value
of the path cost.
The value of this object MUST be retained across
reinitializations of the management system.
Parsed from file RSTP-MIB.mib
Module: RSTP-MIB
Automatically extracted from RFC4318
dot1dStpPortAdminPathCost OBJECT-TYPE SYNTAX Integer32 (0..200000000) MAX-ACCESS read-write STATUS current DESCRIPTION "The administratively assigned value for the contribution of this port to the path cost of paths toward the spanning tree root. Writing a value of '0' assigns the automatically calculated default Path Cost value to the port. If the default Path Cost is being used, this object returns '0' when read. This complements the object dot1dStpPortPathCost or dot1dStpPortPathCost32, which returns the operational value of the path cost. The value of this object MUST be retained across reinitializations of the management system." REFERENCE "IEEE 802.1D-1998: Section 8.5.5.3" ::= { dot1dStpExtPortEntry 6 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.17.2.19.1.1 | dot1dStpPortProtocolMigration | 0 | 0 | When operating in RSTP (version 2) mode, writing true(1) to this object forces this port to transmit RSTP BPDUs. Any other operat… |
1.3.6.1.2.1.17.2.19.1.2 | dot1dStpPortAdminEdgePort | 0 | 0 | The administrative value of the Edge Port parameter. A value of true(1) indicates that this port should be assumed as an edge-po… |
1.3.6.1.2.1.17.2.19.1.3 | dot1dStpPortOperEdgePort | 0 | 0 | The operational value of the Edge Port parameter. The object is initialized to the value of the corresponding instance of dot1dS… |
1.3.6.1.2.1.17.2.19.1.4 | dot1dStpPortAdminPointToPoint | 0 | 0 | The administrative point-to-point status of the LAN segment attached to this port, using the enumeration values of the IEEE 802.1… |
1.3.6.1.2.1.17.2.19.1.5 | dot1dStpPortOperPointToPoint | 0 | 0 | The operational point-to-point status of the LAN segment attached to this port. It indicates whether a port is considered to hav… |