The roles of the syslog application.
pwCepSonetConfigErrorOrStatus OBJECT-TYPE
SYNTAX BITS {
other ( 0),
timeslotInUse ( 1),
timeslotMisuse ( 2),
peerDbaIncompatible ( 3), -- Status only
peerEbmIncompatible ( 4),
peerRtpIncompatible ( 5),
peerAsyncIncompatible ( 6),
peerDbaAsymmetric ( 7), -- Status only
peerEbmAsymmetric ( 8),
peerRtpAsymmetric ( 9),
peerAsyncAsymmetric (10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports a configuration mismatch inside
the local node or between the local node and the peer node.
Some bits indicate an error, and some are simply status
reports that do not affect the forwarding process.
\timeslotInUse\(1) is set when another CEP PW has already
reserved a timeslot (or timeslots) that this CEP PW is
attempting to reserve.
\timeslotMisuse\(2) is set when the stated timeslot this
PW is trying to use is not legal, for example, if
specifying a starting timeslot of 45 for a SONET path of
an STS-12c width.
The peerZZZIncompatible bits are set if the local
configuration is not compatible with the peer configuration
as available from the CEP option received from the peer
through the signaling process and the local node cannot
support such asymmetric configuration.
The peerZZZAsymmetric bits are set if the local
configuration is not compatible with the peer configuration
as available from the CEP option received from the peer
through the signaling process, but the local node can
support such asymmetric configuration."
REFERENCE
"Malis, A., et al., \Synchronous Optical Network/Synchronous
Digital Hierarchy (SONET/SDH) Circuit Emulation over Packet
(CEP)\, RFC 4842, Section 12."
View at oid-info.com
The roles of the syslog application.
syslogControlRoles OBJECT-TYPE SYNTAX SyslogRoles ACCESS read-write STATUS mandatory DESCRIPTION "The roles of the syslog application." ::= { syslogControlEntry 3 }
Automatically extracted from RFC6240
syslogControlRoles OBJECT-TYPE SYNTAX SyslogRoles MAX-ACCESS read-create STATUS current DESCRIPTION "The roles of the syslog application. " ::= { syslogControlEntry 3 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.200.1.1.1.1 | pwCepType, syslogControlIndex | 0 | 0 | The Index that uniquely identifies the syslog application in the syslogControlTable. The value of the index for a syslog applicat… |
1.3.6.1.2.1.200.1.1.1.2 | pwCepSonetIfIndex, syslogControlDescr | 0 | 0 | A user definable description of the syslog application. This description could be used by syslog management applications e.g. in … |
1.3.6.1.2.1.200.1.1.1.4 | pwCepCfgIndex, syslogControlBindAddrType | 0 | 0 | The type of Internet address which follows in syslogControlBindAddr. If this syslog application is not a syslog receiver, the valu… |
1.3.6.1.2.1.200.1.1.1.5 | pwCepTimeElapsed, syslogControlBindAddr | 0 | 0 | pwCepTimeElapsed OBJECT-TYPE SYNTAX HCPerftimeElapsed UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The numb… |
1.3.6.1.2.1.200.1.1.1.6 | pwCepValidIntervals, syslogControlBindPort | 0 | 0 | The port number that this syslog receiver will bind to. If this syslog application is not a syslog receiver the value of this obj… |
1.3.6.1.2.1.200.1.1.1.7 | pwCepIndications, syslogControlEncapsulation | 0 | 0 | The encapsulation that will be used for syslog messages by the syslog receiver. If this syslog application is not a syslog receiv… |
1.3.6.1.2.1.200.1.1.1.8 | pwCepLastEsTimeStamp, syslogControlMaxMessageSize | 0 | 0 | The maximum size of the syslog messages in bytes for this syslog application. A syslog receiver may reject or truncate messages l… |
1.3.6.1.2.1.200.1.1.1.9 | pwCepPeerCepOption, syslogControlConfFileName | 0 | 0 | pwCepPeerCepOption OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the CEP option p… |
1.3.6.1.2.1.200.1.1.1.11 | syslogControlStorageType | 0 | 0 | This object defines whether the parameters defined in this row are kept in volatile storage and lost upon reboot or are backed up… |
1.3.6.1.2.1.200.1.1.1.12 | syslogControlRowStatus | 0 | 0 | This object is used to create, modify and delete rows in the syslogControlTable. The value of syslogControlDescr can be changed wh… |