The number of intervals maintained in the eoEnergyTable.
Each interval is characterized by a specific
eoEnergyCollectionStartTime, used as an index to the
table eoEnergyTable. Whenever the maximum number of
entries is reached, the measurement over the new interval
replaces the oldest measurement. There is one exception
to this rule: when the eoEnergyMaxConsumed and/or
eoEnergyMaxProduced are in (one of) the two oldest
measurement(s), they are left untouched and the next
oldest measurement is replaced.
eoEnergyParametersIntervalNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of intervals maintained in the eoEnergyTable.
Each interval is characterized by a specific
eoEnergyCollectionStartTime, used as an index to the
table eoEnergyTable. Whenever the maximum number of
entries is reached, the measurement over the new interval
replaces the oldest measurement. There is one exception
to this rule: when the eoEnergyMaxConsumed and/or
eoEnergyMaxProduced are in (one of) the two oldest
measurement(s), they are left untouched and the next
oldest measurement is replaced."
DEFVAL { 10 }
View at oid-info.com
The number of intervals maintained in the eoEnergyTable.
Each interval is characterized by a specific
eoEnergyCollectionStartTime, used as an index to the
table eoEnergyTable. Whenever the maximum number of
entries is reached, the measurement over the new interval
replaces the oldest measurement. There is one exception
to this rule: when the eoEnergyMaxConsumed and/or
eoEnergyMaxProduced are in (one of) the two oldest
measurement(s), they are left untouched and the next
oldest measurement is replaced.
eoEnergyParametersIntervalNumber OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The number of intervals maintained in the eoEnergyTable. Each interval is characterized by a specific eoEnergyCollectionStartTime, used as an index to the table eoEnergyTable. Whenever the maximum number of entries is reached, the measurement over the new interval replaces the oldest measurement. There is one exception to this rule: when the eoEnergyMaxConsumed and/or eoEnergyMaxProduced are in (one of) the two oldest measurement(s), they are left untouched and the next oldest measurement is replaced." DEFVAL { 10 } ::= { eoEnergyParametersEntry 4 }
Automatically extracted from IETF RFC7460
eoEnergyParametersIntervalNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The number of intervals maintained in the eoEnergyTable. Each interval is characterized by a specific eoEnergyCollectionStartTime, used as an index to the table eoEnergyTable. Whenever the maximum number of entries is reached, the measurement over the new interval replaces the oldest measurement. There is one exception to this rule: when the eoEnergyMaxConsumed and/or eoEnergyMaxProduced are in (one of) the two oldest measurement(s), they are left untouched and the next oldest measurement is replaced." DEFVAL { 10 } ::= { eoEnergyParametersEntry 4 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.229.1.4.1.2 | eoEnergyParametersIndex | 0 | 0 | This object specifies the index of the Energy Parameters setting for collection of energy measurements for an Energy Object. An … |
1.3.6.1.2.1.229.1.4.1.3 | eoEnergyParametersIntervalLength | 0 | 0 | This object indicates the length of time in hundredths of a second over which to compute the average eoEnergyConsumed measurement… |
1.3.6.1.2.1.229.1.4.1.5 | eoEnergyParametersIntervalMode | 0 | 0 | A control object to define the mode of interval calculation for the computation of the average eoEnergyConsumed or eoEnergyProvid… |
1.3.6.1.2.1.229.1.4.1.6 | eoEnergyParametersIntervalWindow | 0 | 0 | The length of the duration window between the starting time of one sliding window and the next starting time in hundredths of sec… |
1.3.6.1.2.1.229.1.4.1.7 | eoEnergyParametersSampleRate | 0 | 0 | The sampling rate, in milliseconds, at which the Energy Object should poll power usage in order to compute the average eoEnergyCo… |
1.3.6.1.2.1.229.1.4.1.8 | eoEnergyParametersStorageType | 0 | 0 | This variable indicates the storage type for this row. |
1.3.6.1.2.1.229.1.4.1.9 | eoEnergyParametersStatus | 0 | 0 | The status of this row. The eoEnergyParametersStatus is used to start or stop energy usage logging. An entry status may not be … |