The sampling rate, in milliseconds, at which the Energy
Object should poll power usage in order to compute the
average eoEnergyConsumed, eoEnergyProvided measurements
in the table eoEnergyTable. The Energy Object should
initially set this sampling rate to a reasonable value,
i.e., a compromise between intervals that will provide
good accuracy by not being too long, but not so short
that they affect the Energy Object performance by
requesting continuous polling. If the sampling rate is
unknown, the value 0 is reported. The sampling rate
should be selected so that
eoEnergyParametersIntervalWindow is a multiple of
eoEnergyParametersSampleRate. The default value is one
second.
eoEnergyParametersSampleRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The sampling rate, in milliseconds, at which the Energy
Object should poll power usage in order to compute the
average eoEnergyConsumed, eoEnergyProvided measurements
in the table eoEnergyTable. The Energy Object should
initially set this sampling rate to a reasonable value,
i.e., a compromise between intervals that will provide
good accuracy by not being too long, but not so short
that they affect the Energy Object performance by
requesting continuous polling. If the sampling rate is
unknown, the value 0 is reported. The sampling rate
should be selected so that
eoEnergyParametersIntervalWindow is a multiple of
eoEnergyParametersSampleRate. The default value is one
second."
DEFVAL { 1000 }
View at oid-info.com
The sampling rate, in milliseconds, at which the Energy
Object should poll power usage in order to compute the
average eoEnergyConsumed, eoEnergyProvided measurements
in the table eoEnergyTable. The Energy Object should
initially set this sampling rate to a reasonable value,
i.e., a compromise between intervals that will provide
good accuracy by not being too long, but not so short
that they affect the Energy Object performance by
requesting continuous polling. If the sampling rate is
unknown, the value 0 is reported. The sampling rate
should be selected so that
eoEnergyParametersIntervalWindow is a multiple of
eoEnergyParametersSampleRate. The default value is one
second.
eoEnergyParametersSampleRate OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The sampling rate, in milliseconds, at which the Energy Object should poll power usage in order to compute the average eoEnergyConsumed, eoEnergyProvided measurements in the table eoEnergyTable. The Energy Object should initially set this sampling rate to a reasonable value, i.e., a compromise between intervals that will provide good accuracy by not being too long, but not so short that they affect the Energy Object performance by requesting continuous polling. If the sampling rate is unknown, the value 0 is reported. The sampling rate should be selected so that eoEnergyParametersIntervalWindow is a multiple of eoEnergyParametersSampleRate. The default value is one second." DEFVAL { 1000 } ::= { eoEnergyParametersEntry 7 }
Automatically extracted from IETF RFC7460
eoEnergyParametersSampleRate OBJECT-TYPE SYNTAX Unsigned32 UNITS "Milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The sampling rate, in milliseconds, at which the Energy Object should poll power usage in order to compute the average eoEnergyConsumed, eoEnergyProvided measurements in the table eoEnergyTable. The Energy Object should initially set this sampling rate to a reasonable value, i.e., a compromise between intervals that will provide good accuracy by not being too long, but not so short that they affect the Energy Object performance by requesting continuous polling. If the sampling rate is unknown, the value 0 is reported. The sampling rate should be selected so that eoEnergyParametersIntervalWindow is a multiple of eoEnergyParametersSampleRate. The default value is one second." DEFVAL { 1000 } ::= { eoEnergyParametersEntry 7 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.229.1.4.1.2 | eoEnergyParametersIndex | 0 | 0 | This object specifies the index of the Energy Parameters setting for collection of energy measurements for an Energy Object. An … |
1.3.6.1.2.1.229.1.4.1.3 | eoEnergyParametersIntervalLength | 0 | 0 | This object indicates the length of time in hundredths of a second over which to compute the average eoEnergyConsumed measurement… |
1.3.6.1.2.1.229.1.4.1.4 | eoEnergyParametersIntervalNumber | 0 | 0 | The number of intervals maintained in the eoEnergyTable. Each interval is characterized by a specific eoEnergyCollectionStartTime… |
1.3.6.1.2.1.229.1.4.1.5 | eoEnergyParametersIntervalMode | 0 | 0 | A control object to define the mode of interval calculation for the computation of the average eoEnergyConsumed or eoEnergyProvid… |
1.3.6.1.2.1.229.1.4.1.6 | eoEnergyParametersIntervalWindow | 0 | 0 | The length of the duration window between the starting time of one sliding window and the next starting time in hundredths of sec… |
1.3.6.1.2.1.229.1.4.1.8 | eoEnergyParametersStorageType | 0 | 0 | This variable indicates the storage type for this row. |
1.3.6.1.2.1.229.1.4.1.9 | eoEnergyParametersStatus | 0 | 0 | The status of this row. The eoEnergyParametersStatus is used to start or stop energy usage logging. An entry status may not be … |