The length of the duration window between the starting
time of one sliding window and the next starting time in
hundredths of seconds, used to compute the average of
eoEnergyConsumed, eoEnergyProvided measurements in the
eoEnergyTable table. This is valid only when the
eoEnergyParametersIntervalMode is sliding(2). The
eoEnergyParametersIntervalWindow value should be a
multiple of eoEnergyParametersSampleRate.
eoEnergyParametersIntervalWindow OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The length of the duration window between the starting
time of one sliding window and the next starting time in
hundredths of seconds, used to compute the average of
eoEnergyConsumed, eoEnergyProvided measurements in the
eoEnergyTable table. This is valid only when the
eoEnergyParametersIntervalMode is sliding(2). The
eoEnergyParametersIntervalWindow value should be a
multiple of eoEnergyParametersSampleRate."
View at oid-info.com
The length of the duration window between the starting
time of one sliding window and the next starting time in
hundredths of seconds, used to compute the average of
eoEnergyConsumed, eoEnergyProvided measurements in the
eoEnergyTable table. This is valid only when the
eoEnergyParametersIntervalMode is sliding(2). The
eoEnergyParametersIntervalWindow value should be a
multiple of eoEnergyParametersSampleRate.
eoEnergyParametersIntervalWindow OBJECT-TYPE SYNTAX TimeInterval ACCESS read-write STATUS mandatory DESCRIPTION "The length of the duration window between the starting time of one sliding window and the next starting time in hundredths of seconds, used to compute the average of eoEnergyConsumed, eoEnergyProvided measurements in the eoEnergyTable table. This is valid only when the eoEnergyParametersIntervalMode is sliding(2). The eoEnergyParametersIntervalWindow value should be a multiple of eoEnergyParametersSampleRate." ::= { eoEnergyParametersEntry 6 }
Automatically extracted from IETF RFC7460
eoEnergyParametersIntervalWindow OBJECT-TYPE SYNTAX TimeInterval MAX-ACCESS read-create STATUS current DESCRIPTION "The length of the duration window between the starting time of one sliding window and the next starting time in hundredths of seconds, used to compute the average of eoEnergyConsumed, eoEnergyProvided measurements in the eoEnergyTable table. This is valid only when the eoEnergyParametersIntervalMode is sliding(2). The eoEnergyParametersIntervalWindow value should be a multiple of eoEnergyParametersSampleRate." ::= { eoEnergyParametersEntry 6 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.229.1.4.1.2 | eoEnergyParametersIndex | 0 | 0 | This object specifies the index of the Energy Parameters setting for collection of energy measurements for an Energy Object. An … |
1.3.6.1.2.1.229.1.4.1.3 | eoEnergyParametersIntervalLength | 0 | 0 | This object indicates the length of time in hundredths of a second over which to compute the average eoEnergyConsumed measurement… |
1.3.6.1.2.1.229.1.4.1.4 | eoEnergyParametersIntervalNumber | 0 | 0 | The number of intervals maintained in the eoEnergyTable. Each interval is characterized by a specific eoEnergyCollectionStartTime… |
1.3.6.1.2.1.229.1.4.1.5 | eoEnergyParametersIntervalMode | 0 | 0 | A control object to define the mode of interval calculation for the computation of the average eoEnergyConsumed or eoEnergyProvid… |
1.3.6.1.2.1.229.1.4.1.7 | eoEnergyParametersSampleRate | 0 | 0 | The sampling rate, in milliseconds, at which the Energy Object should poll power usage in order to compute the average eoEnergyCo… |
1.3.6.1.2.1.229.1.4.1.8 | eoEnergyParametersStorageType | 0 | 0 | This variable indicates the storage type for this row. |
1.3.6.1.2.1.229.1.4.1.9 | eoEnergyParametersStatus | 0 | 0 | The status of this row. The eoEnergyParametersStatus is used to start or stop energy usage logging. An entry status may not be … |