Reference record for OID 1.3.6.1.2.1.38.1.6.1.5


parent
1.3.6.1.2.1.38.1.6.1 (mdmDTEInterfaceEntry)
node code
5
node name
mdmDTEInactivityTimeout
dot oid
1.3.6.1.2.1.38.1.6.1.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) mdmMIB(38) mdmMIBObjects(1) mdmDTEInterfaceTable(6) mdmDTEInterfaceEntry(1) mdmDTEInactivityTimeout(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) mdmMIB(38) mdmMIB(1) mdmDTEInterfaceTable(6) mdmDTEInterfaceEntry(1) mdmDTEInactivityTimeout(5)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) mdmMIB(38) mdmMIBObjects(1) mdmDTEInterfaceTable(6) mdmDTEInterfaceEntry(1) mdmDTEInactivityTimeout(5)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) mdmMIB(38) mdmMIB(1) mdmDTEInterfaceTable(6) mdmDTEInterfaceEntry(1) mdmDTEInactivityTimeout(5)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) mdmMIB(38) mdmMIBObjects(1) mdmDTEInterfaceTable(6) mdmDTEInterfaceEntry(1) mdmDTEInactivityTimeout(5)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) mdmMIB(38) mdmMIB(1) mdmDTEInterfaceTable(6) mdmDTEInterfaceEntry(1) mdmDTEInactivityTimeout(5)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) mdmMIB(38) mdmMIBObjects(1) mdmDTEInterfaceTable(6) mdmDTEInterfaceEntry(1) mdmDTEInactivityTimeout(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) mdmMIB(38) mdmMIB(1) mdmDTEInterfaceTable(6) mdmDTEInterfaceEntry(1) mdmDTEInactivityTimeout(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/mdmMIB/mdmMIBObjects/mdmDTEInterfaceTable/mdmDTEInterfaceEntry/mdmDTEInactivityTimeout
  • /iso/identified-organization/dod/internet/mgmt/mib-2/mdmMIB/mdmMIB/mdmDTEInterfaceTable/mdmDTEInterfaceEntry/mdmDTEInactivityTimeout
  • ...skipped...
  • /iso/org/dod/internet/mgmt/mib-2/mdmMIB/mdmMIBObjects/mdmDTEInterfaceTable/mdmDTEInterfaceEntry/mdmDTEInactivityTimeout
  • /iso/org/dod/internet/mgmt/mib-2/mdmMIB/mdmMIB/mdmDTEInterfaceTable/mdmDTEInterfaceEntry/mdmDTEInactivityTimeout
  • /iso/org/dod/internet/mgmt/mib/mdmMIB/mdmMIBObjects/mdmDTEInterfaceTable/mdmDTEInterfaceEntry/mdmDTEInactivityTimeout
  • /iso/org/dod/internet/mgmt/mib/mdmMIB/mdmMIB/mdmDTEInterfaceTable/mdmDTEInterfaceEntry/mdmDTEInactivityTimeout
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/mdmMIB/mdmMIBObjects/mdmDTEInterfaceTable/mdmDTEInterfaceEntry/mdmDTEInactivityTimeout
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/mdmMIB/mdmMIB/mdmDTEInterfaceTable/mdmDTEInterfaceEntry/mdmDTEInactivityTimeout
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/38/1/6/1/5

    Description by oid_info

    mdmDTEInactivityTimeout OBJECT-TYPE
    SYNTAX Integer32 (0..65535)
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
    "The amount of idle time in minutes that the modem will wait
    before disconnecting a connection. When a call is connected
    and no data is transferred (continuous marking condition) on
    both circuits 103 and 104 for the specified time, the DCE
    disconnects the call. If the value is 0, no idle disconnect
    will occur. This function applies to asynchronous dial
    operations only and is intended for administrative control
    over idle connections."
    REFERENCE "V.58 inactivityTimerSelect"
    DEFVAL { 0 }

    View at oid-info.com

    Description by mibdepot

    The amount of idle time in minutes that the modem will wait
    before disconnecting a connection. When a call is connected
    and no data is transferred (continuous marking condition) on
    both circuits 103 and 104 for the specified time, the DCE
    disconnects the call. If the value is 0, no idle disconnect
    will occur. This function applies to asynchronous dial
    operations only and is intended for administrative control
    over idle connections.

    Parsed from file rfc1696.mib.txt
    Company: lucent
    Module: Modem-MIB

    Information by oid_info

    Automatically extracted from RFC1696

    Information by mibdepot

    mdmDTEInactivityTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The amount of idle time in minutes that the modem will wait before disconnecting a connection. When a call is connected and no data is transferred (continuous marking condition) on both circuits 103 and 104 for the specified time, the DCE disconnects the call. If the value is 0, no idle disconnect will occur. This function applies to asynchronous dial operations only and is intended for administrative control over idle connections." REFERENCE "V.58 inactivityTimerSelect" DEFVAL { 0 } ::= { mdmDTEInterfaceEntry 5 }

    First Registration Authority (recovered by parent 1.3.6.1.2.1.38)

    Steven Waldbusser

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (4)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.38.1.6.1.1 mdmDTEActionDTROnToOff 0 0 Defines the action the modem will take when DTR drops.

    If the value is set to ignore(1), the modem takes no action
    when DTR drops…
    1.3.6.1.2.1.38.1.6.1.2 mdmDTEActionDTROffToOn 0 0 Defines the action the modem will take when DTR is raised.

    If the value is set to ignore(1), the modem takes no action
    when DTR i…
    1.3.6.1.2.1.38.1.6.1.3 mdmDTESyncTimingSource 0 0 The clock source for synchronous transmissions. If set to
    internal(1), the modem is the clock source and sends the
    clock signals…
    1.3.6.1.2.1.38.1.6.1.4 mdmDTESyncAsyncMode 0 0 The operational mode of the modem. If the value is
    syncAfterDial(3), the modem will accept commands in
    asynchronous mode and cha…