The type of sub-unit within the printer model that this
alert is related. Input, output, and markers are
examples of printer model groups, i.e., examples of
types of sub-units. Wherever possible, these
enumerations match the sub-identifier that identifies
the relevant table in the printmib.
Parsed from file Printer-MIB.mib
Module: Printer-MIB
The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of printer
model groups, i.e., examples of types of sub-units. Wherever
possible, these enumerations match the sub-identifier that
identifies the relevant table in the printmib.
prtAlertGroup OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
other(1),
hostResourcesMIBStorageTable(3),
hostResourcesMIBDeviceTable(4),
generalPrinter(5),
cover(6),
localization(7),
input(8),
output(9),
marker(10),
markerSupplies(11),
markerColorant(12),
mediaPath(13),
channel(14),
interpreter(15),
consoleDisplayBuffer(16),
consoleLights(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of
printer model groups, i.e., examples of types of sub-units.
Whereever possible, these enumerations match the
sub-identifier that identifies the relevant table in the
printmib."
View at oid-info.com
The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of
printer model groups, i.e., examples of types of sub-units.
Whereever possible, these enumerations match the
sub-identifier that identifies the relevant table in the
printmib.
Parsed from file rfc1759.mib.txt
Company: None
Module: Printer-MIB
The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of printer
model groups, i.e., examples of types of sub-units. Wherever
possible, these enumerations match the sub-identifier that
identifies the relevant table in the printmib.
prtAlertGroup OBJECT-TYPE SYNTAX PrtAlertGroupTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Wherever possible, these enumerations match the sub-identifier that identifies the relevant table in the printmib." ::= { prtAlertEntry 4 }
prtAlertGroup OBJECT-TYPE SYNTAX PrtAlertGroupTC ACCESS read-only STATUS mandatory DESCRIPTION "The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Wherever possible, these enumerations match the sub-identifier that identifies the relevant table in the printmib." ::= { prtAlertEntry 4 }
Automatically extracted from RFC1759
prtAlertGroup OBJECT-TYPE SYNTAX INTEGER { other(1), hostResourcesMIBStorageTable(3), hostResourcesMIBDeviceTable(4), generalPrinter(5), cover(6), localization(7), input(8), output(9), marker(10), markerSupplies(11), markerColorant(12), mediaPath(13), channel(14), interpreter(15), consoleDisplayBuffer(16), consoleLights(17) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Whereever possible, these enumerations match the sub-identifier that identifies the relevant table in the printmib." ::= { prtAlertEntry 4 }
prtAlertGroup OBJECT-TYPE SYNTAX PrtAlertGroupTC MAX-ACCESS read-only STATUS current DESCRIPTION "The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Wherever possible, these enumerations match the sub-identifier that identifies the relevant table in the printmib." ::= { prtAlertEntry 4 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.43.18.1.1.1 | prtAlertIndex | 0 | 0 | The index value used to determine which alerts have been added or removed from the alert table. This is an incrementing integer s… |
1.3.6.1.2.1.43.18.1.1.2 | prtAlertSeverityLevel | 0 | 0 | The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table. |
1.3.6.1.2.1.43.18.1.1.3 | prtAlertTrainingLevel | 0 | 0 | See textual convention PrtAlertTrainingLevelTC |
1.3.6.1.2.1.43.18.1.1.5 | prtAlertGroupIndex | 0 | 0 | An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the print… |
1.3.6.1.2.1.43.18.1.1.6 | prtAlertLocation | 0 | 0 | The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designa… |
1.3.6.1.2.1.43.18.1.1.7 | prtAlertCode | 0 | 0 | See associated textual convention PrtAlertCodeTC |
1.3.6.1.2.1.43.18.1.1.8 | prtAlertDescription | 0 | 0 | A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by… |
1.3.6.1.2.1.43.18.1.1.9 | prtAlertTime | 0 | 0 | The value of sysUpTime at the time that this alert was generated. |