The sub-unit location that is defined by the printer
manufacturer to further refine the location of this
alert within the designated sub-unit. The location is
used in conjunction with the Group and GroupIndex
values; for example, there is an alert in Input #2 at
location number 7. The value (-2) indicates unknown
Parsed from file Printer-MIB.mib
Module: Printer-MIB
The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction with the Group and GroupIndex values; for example,
there is an alert in Input #2 at location number 7. The value
(-2) indicates unknown.
NOTE: The above description has been modified from RFC 1759
for clarification.
prtAlertLocation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction with the Group and GroupIndex values; for
example, there is an alert in Input #2 at location number 7."
View at oid-info.com
The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction with the Group and GroupIndex values; for
example, there is an alert in Input #2 at location number 7.
Parsed from file rfc1759.mib.txt
Company: None
Module: Printer-MIB
The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction with the Group and GroupIndex values; for example,
there is an alert in Input #2 at location number 7. The value
(-2) indicates unknown.
NOTE: The above description has been modified from RFC 1759
for clarification.
prtAlertLocation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Input #2 at location number 7. The value (-2) indicates unknown" ::= { prtAlertEntry 6 }
prtAlertLocation OBJECT-TYPE SYNTAX INTEGER(-2..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Input #2 at location number 7. The value (-2) indicates unknown. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtAlertEntry 6 }
Automatically extracted from RFC1759
prtAlertLocation OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Input #2 at location number 7." ::= { prtAlertEntry 6 }
prtAlertLocation OBJECT-TYPE SYNTAX Integer32 (-2..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Input #2 at location number 7. The value (-2) indicates unknown. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtAlertEntry 6 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.43.18.1.1.1 | prtAlertIndex | 0 | 0 | The index value used to determine which alerts have been added or removed from the alert table. This is an incrementing integer s… |
1.3.6.1.2.1.43.18.1.1.2 | prtAlertSeverityLevel | 0 | 0 | The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table. |
1.3.6.1.2.1.43.18.1.1.3 | prtAlertTrainingLevel | 0 | 0 | See textual convention PrtAlertTrainingLevelTC |
1.3.6.1.2.1.43.18.1.1.4 | prtAlertGroup | 0 | 0 | The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer mode… |
1.3.6.1.2.1.43.18.1.1.5 | prtAlertGroupIndex | 0 | 0 | An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the print… |
1.3.6.1.2.1.43.18.1.1.7 | prtAlertCode | 0 | 0 | See associated textual convention PrtAlertCodeTC |
1.3.6.1.2.1.43.18.1.1.8 | prtAlertDescription | 0 | 0 | A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by… |
1.3.6.1.2.1.43.18.1.1.9 | prtAlertTime | 0 | 0 | The value of sysUpTime at the time that this alert was generated. |