Reference record for OID 1.3.6.1.4.1.1597.1.4.1.1


parent
1.3.6.1.4.1.1597.1.4.1 (dptScsiDevTable)
node code
1
node name
dptScsiDevEntry
dot oid
1.3.6.1.4.1.1597.1.4.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dpt(1597) dptScsi(1) dptScsiDev(4) dptScsiDevTable(1) dptScsiDevEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dpt(1597) dptScsi(1) dptScsiDev(4) dptScsiDevTable(1) dptScsiDevEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dpt(1597) dptScsi(1) dptScsiDev(4) dptScsiDevTable(1) dptScsiDevEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dpt(1597) dptScsi(1) dptScsiDev(4) dptScsiDevTable(1) dptScsiDevEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dpt(1597) dptScsi(1) dptScsiDev(4) dptScsiDevTable(1) dptScsiDevEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dpt(1597) dptScsi(1) dptScsiDev(4) dptScsiDevTable(1) dptScsiDevEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/dpt/dptScsi/dptScsiDev/dptScsiDevTable/dptScsiDevEntry
  • /iso/identified-organization/dod/internet/private/enterprises/dpt/dptScsi/dptScsiDev/dptScsiDevTable/dptScsiDevEntry
  • /iso/org/dod/internet/private/enterprise/dpt/dptScsi/dptScsiDev/dptScsiDevTable/dptScsiDevEntry
  • /iso/org/dod/internet/private/enterprises/dpt/dptScsi/dptScsiDev/dptScsiDevTable/dptScsiDevEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/dpt/dptScsi/dptScsiDev/dptScsiDevTable/dptScsiDevEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dpt/dptScsi/dptScsiDev/dptScsiDevTable/dptScsiDevEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/1597/1/4/1/1

    Description by mibdepot

    These parameters describe/control a particular SCSI Device.
    The index for this entry is the logical device address of
    the SCSI device. The logical device address consist of five
    components: HBA number, SCSI bus number, device ID,
    LUN and level.

    Parsed from file Dpt.mib.txt
    Company: None
    Module: DPT-SCSI-MIB

    Description by circitor

    These parameters describe/control a particular SCSI Device.
    The index for this entry is the logical device address of
    the SCSI device. The logical device address consists of five
    components: contoller number, SCSI bus number, Device ID,
    LUN and level.

    Parsed from file DPT-SCSI-MIB.mib
    Module: DPT-SCSI-MIB

    Information by oid_info

    Vendor: Distributed Processing Technology
    Module: DPT-SCSI-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    dptScsiDevEntry OBJECT-TYPE SYNTAX DptScsiDevEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "These parameters describe/control a particular SCSI Device. The index for this entry is the logical device address of the SCSI device. The logical device address consist of five components: HBA number, SCSI bus number, device ID, LUN and level." INDEX { dptScsiHbaNumber, dptScsiBusNumber, dptScsiDevId, dptScsiDevLun, dptScsiDevLevel } ::= { dptScsiDevTable 1 }

    Information by circitor

    dptScsiDevEntry OBJECT-TYPE SYNTAX DptScsiDevEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "These parameters describe/control a particular SCSI Device. The index for this entry is the logical device address of the SCSI device. The logical device address consists of five components: contoller number, SCSI bus number, Device ID, LUN and level." INDEX { dptScsiHbaNumber, dptScsiBusNumber, dptScsiDevId, dptScsiDevLun, dptScsiDevLevel } ::= { dptScsiDevTable 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.1597)

    Ballard Joseph A.

    Children (35)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.1597.1.4.1.1.1 dptScsiDevId 0 0 The SCSI Id of the device.
    1.3.6.1.4.1.1597.1.4.1.1.2 dptScsiDevLun 0 0 The SCSI logical unit number of the device.
    1.3.6.1.4.1.1597.1.4.1.1.3 dptScsiDevLevel 0 0 Indicates the Level of the device.
    Level 0 indicates physical devices, while level 1 and 2
    indicate logical devices. It also give…
    1.3.6.1.4.1.1597.1.4.1.1.4 dptScsiDevVendor 0 0 The name of the vendor of the device.
    1.3.6.1.4.1.1597.1.4.1.1.5 dptScsiDevModel 0 0 The model name of the device.
    1.3.6.1.4.1.1597.1.4.1.1.6 dptScsiDevRevision 0 0 The revision level of the device.
    1.3.6.1.4.1.1597.1.4.1.1.7 dptScsiDevSerialNumber 0 0 The serial number of the device.
    1.3.6.1.4.1.1597.1.4.1.1.8 dptScsiDevStatus 0 0 The administrative state of the device. The following are
    all the possible values:
    invalid - current value is invalid.
    optim…
    1.3.6.1.4.1.1597.1.4.1.1.9 dptScsiDevBusWidth 0 0 The data width of the SCSI device.
    1.3.6.1.4.1.1597.1.4.1.1.10 dptScsiDevCapacity 0 0 The storage capacity of the device in MB.
    1.3.6.1.4.1.1597.1.4.1.1.11 dptScsiDevLogicalBlockSize 0 0 Logical block size of the device in bytes.
    1.3.6.1.4.1.1597.1.4.1.1.12 dptScsiDevPhysicalBlockSize 0 0 Physical block size of the device in bytes.
    1.3.6.1.4.1.1597.1.4.1.1.13 dptScsiDevNegTransferRate, dptScsiDevMaxTransferRate 0 0 The maximum data transfer rate of the
    device in MB/s.
    1.3.6.1.4.1.1597.1.4.1.1.14 dptScsiDevRemovable 0 0 Indicates whether or not the device is removable.
    1.3.6.1.4.1.1597.1.4.1.1.15 dptScsiDevEccEnabled 0 0 Indicates whether the device has ECC enabled or
    disabled.
    1.3.6.1.4.1.1597.1.4.1.1.16 dptScsiDevScsiVersion 0 0 Indicates the SCSI specification version of the device.
    1.3.6.1.4.1.1597.1.4.1.1.17 dptScsiDevSoftReset 0 0 Indicates whether the device supports soft reset.
    1.3.6.1.4.1.1597.1.4.1.1.18 dptScsiDevCmdQueuing 0 0 Indicates whether the device is supports command queuing.
    1.3.6.1.4.1.1597.1.4.1.1.19 dptScsiDevLinkedCmds 0 0 Indicates whether the device is linked commands
    capable.
    1.3.6.1.4.1.1597.1.4.1.1.20 dptScsiDevSynchronous 0 0 Indicates whether the device supports synchronous
    data transfers.
    1.3.6.1.4.1.1597.1.4.1.1.21 dptScsiDevRelAddr 0 0 Indicates whether the device supports relative
    addressing.
    1.3.6.1.4.1.1597.1.4.1.1.22 dptScsiDevSMART 0 0 Indicates whether the device supports
    SMART specifications.
    1.3.6.1.4.1.1597.1.4.1.1.23 dptScsiDevSCAM 0 0 Indicates whether the device supports SCAM.
    1.3.6.1.4.1.1597.1.4.1.1.24 dptScsiDevBadBlockNumber 0 0 If bad blocks have been detected on the device, this
    is the address of the most recent one. Otherwise it
    will contain 0 (no error…
    1.3.6.1.4.1.1597.1.4.1.1.25 dptScsiDevBadBlockCount 0 0 This represents the total number of the bad blocks
    encountered most recently on the device starting at
    the block number dptScsiDe…
    1.3.6.1.4.1.1597.1.4.1.1.26 dptScsiDevErrorsAboveThreshold 0 0 Indicates whether or not the error count of the device
    has reached the threshold.
    1.3.6.1.4.1.1597.1.4.1.1.27 dptScsiDevDriveLockingOn 0 0 Indicates whether or not the drive is locked.
    1.3.6.1.4.1.1597.1.4.1.1.28 dptScsiDevLastReqSenseInfo 0 0 The request sense information. It is used in the
    definition of one or more traps.
    1.3.6.1.4.1.1597.1.4.1.1.29 dptScsiDevReadCachingOn 0 0 Indicates whether or not read caching is on.
    1.3.6.1.4.1.1597.1.4.1.1.30 dptScsiDevReadCacheMaxRecord 0 0 Maximum record size for read caching.
    1.3.6.1.4.1.1597.1.4.1.1.31 dptScsiDevWriteCachingOn 0 0 Indicates whether or not write caching is on.
    1.3.6.1.4.1.1597.1.4.1.1.32 dptScsiDevWriteCacheMaxRecord 0 0 Maximum record size for write caching.
    1.3.6.1.4.1.1597.1.4.1.1.33 dptScsiDevWriteMode 0 0 The write modes are Write-back and Write-through, with
    write-back being the default.

    In write-back mode the controller will cache…
    1.3.6.1.4.1.1597.1.4.1.1.34 dptScsiDevSmartStatusOk 0 0 Indicates whether the device has reported a SMART
    error not (not applicable to logical devices).
    1.3.6.1.4.1.1597.1.4.1.1.35 dptScsiDevType 0 0 Type of device reported.