Total Seeks (high).
The phyDrvHSeeks and the phyDrvSeeks together shows the total
number of seek operations performed by the physical disk drive
during the reference hours (phyDrvRefHours).
The actual number of seeks equals the phyDrvHSeeks times
2^32 plus the phyDrvWriteSeeks.
If the value cannot be determined, 4,294,967,295 is
returned.
Parsed from file CPQFCA2.MIB.txt
Company: None
Module: CPQFCA-MIB
Total Seeks (high).
The phyDrvHSeeks and the phyDrvSeeks together shows the total
number of seek operations performed by the physical disk drive
during the reference hours (phyDrvRefHours).
The actual number of seeks equals the phyDrvHSeeks times
2^32 plus the phyDrvWriteSeeks.
If the value cannot be determined, 4,294,967,295 is
returned.
Parsed from file CPQFCA-MIB.mib
Module: CPQFCA-MIB
cpqFcaPhyDrvHSeeks OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Seeks (high). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physical disk drive during the reference hours (phyDrvRefHours). The actual number of seeks equals the phyDrvHSeeks times 2^32 plus the phyDrvWriteSeeks. If the value cannot be determined, 4,294,967,295 is returned." ::= { cpqFcaPhyDrvEntry 13 }
Vendor: Compaq
Module: CPQFCA-MIB
[Automatically extracted from oidview.com]
cpqFcaPhyDrvHSeeks OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Seeks (high). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physical disk drive during the reference hours (phyDrvRefHours). The actual number of seeks equals the phyDrvHSeeks times 2^32 plus the phyDrvWriteSeeks. If the value cannot be determined, 4,294,967,295 is returned." ::= { cpqFcaPhyDrvEntry 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.16.2.5.1.1.1 | cpqFcaPhyDrvBoxIndex | 0 | 0 | External Array Physical Drive Storage Box Index. The storage box index indicates which storage box this physical drive is in. |
1.3.6.1.4.1.232.16.2.5.1.1.2 | cpqFcaPhyDrvIndex | 0 | 0 | External Array Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the… |
1.3.6.1.4.1.232.16.2.5.1.1.3 | cpqFcaPhyDrvModel | 0 | 0 | External Array Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who ma… |
1.3.6.1.4.1.232.16.2.5.1.1.4 | cpqFcaPhyDrvFWRev | 0 | 0 | External Array Physical Drive Firmware Revision. This shows the physical drive firmware revision number. |
1.3.6.1.4.1.232.16.2.5.1.1.5 | cpqFcaPhyDrvBay | 0 | 0 | External Array Physical Drive Bay Location. This value matches the bay location where the physical drive has been installed. Eac… |
1.3.6.1.4.1.232.16.2.5.1.1.6 | cpqFcaPhyDrvStatus | 0 | 0 | Fibre Channel Array Physical Drive Status. This shows the status of the physical drive. The following values are valid for the ph… |
1.3.6.1.4.1.232.16.2.5.1.1.7 | cpqFcaPhyDrvUsedReallocs | 0 | 0 | External Array Physical Drive Used Reallocated Sectors. This shows the number of sectors of the reallocation area that have been … |
1.3.6.1.4.1.232.16.2.5.1.1.8 | cpqFcaPhyDrvRefHours | 0 | 0 | External Array Reference Time in hours. This shows the total number of hours that a physical drive has been spinning since the dr… |
1.3.6.1.4.1.232.16.2.5.1.1.9 | cpqFcaPhyDrvHReads | 0 | 0 | External Array Physical Drive Sectors Read (high). The phyDrvHReads and the phyDrvReads together shows the total number of sector… |
1.3.6.1.4.1.232.16.2.5.1.1.10 | cpqFcaPhyDrvReads | 0 | 0 | External Array Physical Drive Sectors Read (low). The phyDrvHReads and the phyDrvReads together shows the total number of sectors… |
1.3.6.1.4.1.232.16.2.5.1.1.11 | cpqFcaPhyDrvHWrites | 0 | 0 | Sectors Written (high). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical… |
1.3.6.1.4.1.232.16.2.5.1.1.12 | cpqFcaPhyDrvWrites | 0 | 0 | Sectors Written (low). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical d… |
1.3.6.1.4.1.232.16.2.5.1.1.14 | cpqFcaPhyDrvSeeks | 0 | 0 | Total Seeks (low). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physi… |
1.3.6.1.4.1.232.16.2.5.1.1.15 | cpqFcaPhyDrvHardReadErrs | 0 | 0 | Hard Read Errors. This shows the number of read errors that have occurred on a drive that could not be recovered by a physical dr… |
1.3.6.1.4.1.232.16.2.5.1.1.16 | cpqFcaPhyDrvRecvReadErrs | 0 | 0 | Recovered Read Errors. This shows the number of read errors corrected through physical drive retries during the reference time (p… |
1.3.6.1.4.1.232.16.2.5.1.1.17 | cpqFcaPhyDrvHardWriteErrs | 0 | 0 | Hard Write Errors. This shows the number of write errors that could not be recovered by a physical drive during the reference tim… |
1.3.6.1.4.1.232.16.2.5.1.1.18 | cpqFcaPhyDrvRecvWriteErrs | 0 | 0 | Recovered Write Errors. This shows the number of write errors corrected through physical drive retries or recovered by a physical… |
1.3.6.1.4.1.232.16.2.5.1.1.19 | cpqFcaPhyDrvHSeekErrs | 0 | 0 | Seek Errors (High). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk dr… |
1.3.6.1.4.1.232.16.2.5.1.1.20 | cpqFcaPhyDrvSeekErrs | 0 | 0 | Seek Errors (low). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk dri… |
1.3.6.1.4.1.232.16.2.5.1.1.21 | cpqFcaPhyDrvSpinupTime | 0 | 0 | Spin up Time in tenths of seconds. This is the time it takes for a physical drive to spin up to full speed. Disks require time to … |
1.3.6.1.4.1.232.16.2.5.1.1.22 | cpqFcaPhyDrvFunctTest1 | 0 | 0 | Functional Test 1. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.16.2.5.1.1.23 | cpqFcaPhyDrvFunctTest2 | 0 | 0 | Functional Test 2. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.16.2.5.1.1.24 | cpqFcaPhyDrvFunctTest3 | 0 | 0 | Functional Test 3. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.16.2.5.1.1.25 | cpqFcaPhyDrvOtherTimeouts | 0 | 0 | Other Timeouts. The number of times that a physical drive did not respond with an interrupt within a controller-defined period of… |
1.3.6.1.4.1.232.16.2.5.1.1.26 | cpqFcaPhyDrvBadRecvReads | 0 | 0 | Recovery Failed (Bad) Read Error. The number of times a read error occurred while performing Automatic Data Recovery from this ph… |
1.3.6.1.4.1.232.16.2.5.1.1.27 | cpqFcaPhyDrvBadRecvWrites | 0 | 0 | Recovery Failed (Bad) Write Error. The number of times a write error occurred while performing Automatic Data Recovery from anoth… |
1.3.6.1.4.1.232.16.2.5.1.1.28 | cpqFcaPhyDrvFormatErrs | 0 | 0 | Format Error. The number of times a format operation failed when the controller attempted to remap a bad sector during the refere… |
1.3.6.1.4.1.232.16.2.5.1.1.29 | cpqFcaPhyDrvNotReadyErrs | 0 | 0 | Drive Not Ready Errors. The number of times the physical drive failed after the spin up command was issued during the reference t… |
1.3.6.1.4.1.232.16.2.5.1.1.30 | cpqFcaPhyDrvHasMonInfo | 0 | 0 | Physical Drive Has Monitor Information. All of the physical disk table fields except for the physical disk status (phyDrvStatus) … |
1.3.6.1.4.1.232.16.2.5.1.1.31 | cpqFcaPhyDrvCondition | 0 | 0 | The condition of the device. This value represents the overall condition of this physical drive. |
1.3.6.1.4.1.232.16.2.5.1.1.32 | cpqFcaPhyDrvHotPlugs | 0 | 0 | Physical Drive Hot Plug Count. This value indicates the number of times this physical drive was hot-plugged (removed) from a stor… |
1.3.6.1.4.1.232.16.2.5.1.1.33 | cpqFcaPhyDrvMediaErrs | 0 | 0 | Physical Drive Media Failure Count. This value indicates the number of times this physical drive was failed due to unrecoverable … |
1.3.6.1.4.1.232.16.2.5.1.1.34 | cpqFcaPhyDrvHardwareErrs | 0 | 0 | Physical Drive Hardware Error Count. This value indicates the number of times this physical drive returned a bad hardware status.… |
1.3.6.1.4.1.232.16.2.5.1.1.35 | cpqFcaPhyDrvAbortedCmds | 0 | 0 | Physical Drive Aborted Command Failures. This value indicates the number of times this physical drive was failed due to aborted c… |
1.3.6.1.4.1.232.16.2.5.1.1.36 | cpqFcaPhyDrvSpinUpErrs | 0 | 0 | Physical Drive Spin-Up Failure Count. This value indicates the number of times this physical drive was failed due to a failure of… |
1.3.6.1.4.1.232.16.2.5.1.1.37 | cpqFcaPhyDrvBadTargetErrs | 0 | 0 | Physical Drive Bad Target Count. This value indicates the number of times this physical drive performed some action that did not … |
1.3.6.1.4.1.232.16.2.5.1.1.38 | cpqFcaPhyDrvSize | 0 | 0 | Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,5… |
1.3.6.1.4.1.232.16.2.5.1.1.39 | cpqFcaPhyDrvBusFaults | 0 | 0 | Physical Drive Bus Fault Count. This value indicates the number of times that a bus fault was detected for the drive by the contr… |
1.3.6.1.4.1.232.16.2.5.1.1.40 | cpqFcaPhyDrvHotPlug | 0 | 0 | Physical Drive Hot Plug Support Status. The following values are defined: other(1) The Insight Agent is unable to determine if thi… |
1.3.6.1.4.1.232.16.2.5.1.1.41 | cpqFcaPhyDrvPlacement | 0 | 0 | Physical Drive Placement. The following values are defined: other(1) The agent is unable to determine if the drive is internal or e… |
1.3.6.1.4.1.232.16.2.5.1.1.42 | cpqFcaPhyDrvBusNumber | 0 | 0 | Physical Drive SCSI Bus Number. The bus number indicates to which SCSI bus this physical drive is attached. The first instance i… |
1.3.6.1.4.1.232.16.2.5.1.1.43 | cpqFcaPhyDrvSerialNum | 0 | 0 | Physical Drive Serial Number. This is the serial number assigned to the physical drive. This value is based upon the serial numbe… |
1.3.6.1.4.1.232.16.2.5.1.1.44 | cpqFcaPhyDrvPreFailMonitoring | 0 | 0 | Physical Drive Predictive Failure Monitoring. The following values are defined: other(1) The agent is unable to determine if the d… |
1.3.6.1.4.1.232.16.2.5.1.1.45 | cpqFcaPhyDrvCurrentWidth | 0 | 0 | Physical Drive Current Width. The following values are defined: other(1) The agent is unable to determine the current negotiated d… |
1.3.6.1.4.1.232.16.2.5.1.1.46 | cpqFcaPhyDrvCurrentSpeed | 0 | 0 | Physical Drive Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determine the curren… |
1.3.6.1.4.1.232.16.2.5.1.1.47 | cpqFcaPhyDrvFailureCode | 0 | 0 | Physical Drive Failure Code. This value is the drive failure reason code returned by the array firmware. It is valid only when t… |
1.3.6.1.4.1.232.16.2.5.1.1.48 | cpqFcaPhyDrvBlinkTime | 0 | 0 | Physical Drive LED Blink Time. This value is the amount of time remaining for the drive LEDs to blink in tenths of seconds. A va… |
1.3.6.1.4.1.232.16.2.5.1.1.49 | cpqFcaPhyDrvSmartStatus | 0 | 0 | Physical Drive S.M.A.R.T Status. The following values are defined: other(1) The agent is unable to determine if the status of S.M.… |
1.3.6.1.4.1.232.16.2.5.1.1.50 | cpqFcaPhyDrvRotationalSpeed | 0 | 0 | Physical Drive Rotational Speed. The following values are defined: other(1) The agent is unable to determine the rotational speed … |
1.3.6.1.4.1.232.16.2.5.1.1.51 | cpqFcaPhyDrvType | 0 | 0 | Physical Drive Type. The following values are defined: other(1) The agent is unable to determine the type for this drive. parallelS… |
1.3.6.1.4.1.232.16.2.5.1.1.52 | cpqFcaPhyDrvSataVersion | 0 | 0 | Physical Drive SATA Version. The following values are defined: other(1) The agent is unable to determine the SATA version for this… |
1.3.6.1.4.1.232.16.2.5.1.1.53 | cpqFcaPhyDrvBoxConnector | 0 | 0 | Physical Drive Box Connector. This is the box connector to which the drive is ultimately attached. If the box connector cannot b… |
1.3.6.1.4.1.232.16.2.5.1.1.54 | cpqFcaPhyDrvBoxOnConnector | 0 | 0 | Physical Drive Box on Connector. The box on connector indicates to which box instance this physical drive belongs. The instances… |
1.3.6.1.4.1.232.16.2.5.1.1.55 | cpqFcaPhyDrvLocationString | 0 | 0 | Physical Drive Location String. This string describes the location of the drive in relation to the storage box. If the location … |
1.3.6.1.4.1.232.16.2.5.1.1.56 | cpqFcaPhyDrvNegotiatedLinkRate | 0 | 0 | Physical Drive Negotiated Link Rate. The following values are defined: other(1) The agent is unable to determine the negotiated li… |
1.3.6.1.4.1.232.16.2.5.1.1.57 | cpqFcaPhyDrvPhyCount | 0 | 0 | Physical Drive PHY Count. This value indicates how many PHYs exist on a SAS or SATA disk drive. If the value cannot be determine… |
1.3.6.1.4.1.232.16.2.5.1.1.58 | cpqFcaPhyDrvUnsupportedDrive | 0 | 0 | Physical Drive Unsupported Drive. The following values are defined: other(1) The agent is unable to determine the value for this d… |