Reference record for OID 1.3.6.1.4.1.232.16.2.5.1.1.52



parent
1.3.6.1.4.1.232.16.2.5.1.1 (cpqFcaPhyDrvEntry)
node code
52
node name
cpqFcaPhyDrvSataVersion
dot oid
1.3.6.1.4.1.232.16.2.5.1.1.52
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvSataVersion(52)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvSataVersion(52)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvSataVersion(52)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvSataVersion(52)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvSataVersion(52)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvSataVersion(52)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvSataVersion(52)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvSataVersion(52)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvSataVersion
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvSataVersion
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvSataVersion
  • /iso/org/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvSataVersion
  • /iso/org/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvSataVersion
  • /iso/org/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvSataVersion
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvSataVersion
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvSataVersion
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/16/2/5/1/1/52

    Description by mibdepot

    Physical Drive SATA Version.

    The following values are defined:

    other(1)
    The agent is unable to determine the SATA version for this
    drive or it is not a SATA drive.

    sataOne(2)
    The drive is SATA version one.

    sataTwo(3)
    The drive is SATA version two.

    Parsed from file CPQFCA2.MIB.txt
    Company: None
    Module: CPQFCA-MIB

    Description by circitor

    Physical Drive SATA Version.

    The following values are defined:

    other(1)
    The agent is unable to determine the SATA version for this
    drive or it is not a SATA drive.

    sataOne(2)
    The drive is SATA version one.

    sataTwo(3)
    The drive is SATA version two.

    Parsed from file CPQFCA-MIB.mib
    Module: CPQFCA-MIB

    Information by mibdepot

    cpqFcaPhyDrvSataVersion OBJECT-TYPE SYNTAX INTEGER { other(1), sataOne(2), sataTwo(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Physical Drive SATA Version. The following values are defined: other(1) The agent is unable to determine the SATA version for this drive or it is not a SATA drive. sataOne(2) The drive is SATA version one. sataTwo(3) The drive is SATA version two." ::= { cpqFcaPhyDrvEntry 52 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQFCA-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqFcaPhyDrvSataVersion OBJECT-TYPE SYNTAX INTEGER { other(1), sataOne(2), sataTwo(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Physical Drive SATA Version. The following values are defined: other(1) The agent is unable to determine the SATA version for this drive or it is not a SATA drive. sataOne(2) The drive is SATA version one. sataTwo(3) The drive is SATA version two." ::= { cpqFcaPhyDrvEntry 52 }

    Brothers (57)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.16.2.5.1.1.1 cpqFcaPhyDrvBoxIndex 0 0 External Array Physical Drive Storage Box Index.

    The storage box index indicates which storage box this physical
    drive is in.
    1.3.6.1.4.1.232.16.2.5.1.1.2 cpqFcaPhyDrvIndex 0 0 External Array Physical Drive Index.

    This index is used for selecting the physical drive table entry.
    This number, along with the…
    1.3.6.1.4.1.232.16.2.5.1.1.3 cpqFcaPhyDrvModel 0 0 External Array Physical Drive Model.

    This is a text description of the physical drive. The text that
    appears depends upon who ma…
    1.3.6.1.4.1.232.16.2.5.1.1.4 cpqFcaPhyDrvFWRev 0 0 External Array Physical Drive Firmware Revision.

    This shows the physical drive firmware revision number.
    1.3.6.1.4.1.232.16.2.5.1.1.5 cpqFcaPhyDrvBay 0 0 External Array Physical Drive Bay Location.

    This value matches the bay location where the physical drive has
    been installed. Eac…
    1.3.6.1.4.1.232.16.2.5.1.1.6 cpqFcaPhyDrvStatus 0 0 Fibre Channel Array Physical Drive Status.

    This shows the status of the physical drive.

    The following values are valid for the ph…
    1.3.6.1.4.1.232.16.2.5.1.1.7 cpqFcaPhyDrvUsedReallocs 0 0 External Array Physical Drive Used Reallocated Sectors.

    This shows the number of sectors of the reallocation area that
    have been …
    1.3.6.1.4.1.232.16.2.5.1.1.8 cpqFcaPhyDrvRefHours 0 0 External Array Reference Time in hours.

    This shows the total number of hours that a physical drive has
    been spinning since the dr…
    1.3.6.1.4.1.232.16.2.5.1.1.9 cpqFcaPhyDrvHReads 0 0 External Array Physical Drive Sectors Read (high).

    The phyDrvHReads and the phyDrvReads together shows the total
    number of sector…
    1.3.6.1.4.1.232.16.2.5.1.1.10 cpqFcaPhyDrvReads 0 0 External Array Physical Drive Sectors Read (low).

    The phyDrvHReads and the phyDrvReads together shows
    the total number of sectors…
    1.3.6.1.4.1.232.16.2.5.1.1.11 cpqFcaPhyDrvHWrites 0 0 Sectors Written (high).

    The phyDrvHWrites and the phyDrvWrites together shows the
    total number of sectors written to the physical…
    1.3.6.1.4.1.232.16.2.5.1.1.12 cpqFcaPhyDrvWrites 0 0 Sectors Written (low).

    The phyDrvHWrites and the phyDrvWrites together
    shows the total number of sectors written to the physical
    d…
    1.3.6.1.4.1.232.16.2.5.1.1.13 cpqFcaPhyDrvHSeeks 0 0 Total Seeks (high).

    The phyDrvHSeeks and the phyDrvSeeks together shows the total
    number of seek operations performed by the phys…
    1.3.6.1.4.1.232.16.2.5.1.1.14 cpqFcaPhyDrvSeeks 0 0 Total Seeks (low).

    The phyDrvHSeeks and the phyDrvSeeks together shows the total
    number of seek operations performed by the physi…
    1.3.6.1.4.1.232.16.2.5.1.1.15 cpqFcaPhyDrvHardReadErrs 0 0 Hard Read Errors.

    This shows the number of read errors that have occurred on a
    drive that could not be recovered by a physical dr…
    1.3.6.1.4.1.232.16.2.5.1.1.16 cpqFcaPhyDrvRecvReadErrs 0 0 Recovered Read Errors.

    This shows the number of read errors corrected through physical
    drive retries during the reference time (p…
    1.3.6.1.4.1.232.16.2.5.1.1.17 cpqFcaPhyDrvHardWriteErrs 0 0 Hard Write Errors.

    This shows the number of write errors that could not be recovered
    by a physical drive during the reference tim…
    1.3.6.1.4.1.232.16.2.5.1.1.18 cpqFcaPhyDrvRecvWriteErrs 0 0 Recovered Write Errors.

    This shows the number of write errors corrected through physical
    drive retries or recovered by a physical…
    1.3.6.1.4.1.232.16.2.5.1.1.19 cpqFcaPhyDrvHSeekErrs 0 0 Seek Errors (High).

    The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
    total number of times that the physical disk dr…
    1.3.6.1.4.1.232.16.2.5.1.1.20 cpqFcaPhyDrvSeekErrs 0 0 Seek Errors (low).
    The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
    total number of times that the physical disk dri…
    1.3.6.1.4.1.232.16.2.5.1.1.21 cpqFcaPhyDrvSpinupTime 0 0 Spin up Time in tenths of seconds.

    This is the time it takes for a physical drive to spin up to full
    speed.

    Disks require time to …
    1.3.6.1.4.1.232.16.2.5.1.1.22 cpqFcaPhyDrvFunctTest1 0 0 Functional Test 1.

    This provides information about a series of tests that indicate
    how well a physical drive works. These tests c…
    1.3.6.1.4.1.232.16.2.5.1.1.23 cpqFcaPhyDrvFunctTest2 0 0 Functional Test 2.

    This provides information about a series of tests that indicate
    how well a physical drive works. These tests c…
    1.3.6.1.4.1.232.16.2.5.1.1.24 cpqFcaPhyDrvFunctTest3 0 0 Functional Test 3.

    This provides information about a series of tests that indicate
    how well a physical drive works. These tests c…
    1.3.6.1.4.1.232.16.2.5.1.1.25 cpqFcaPhyDrvOtherTimeouts 0 0 Other Timeouts.

    The number of times that a physical drive did not respond with an
    interrupt within a controller-defined period of…
    1.3.6.1.4.1.232.16.2.5.1.1.26 cpqFcaPhyDrvBadRecvReads 0 0 Recovery Failed (Bad) Read Error.

    The number of times a read error occurred while performing
    Automatic Data Recovery from this ph…
    1.3.6.1.4.1.232.16.2.5.1.1.27 cpqFcaPhyDrvBadRecvWrites 0 0 Recovery Failed (Bad) Write Error.

    The number of times a write error occurred while performing
    Automatic Data Recovery from anoth…
    1.3.6.1.4.1.232.16.2.5.1.1.28 cpqFcaPhyDrvFormatErrs 0 0 Format Error.

    The number of times a format operation failed when the controller
    attempted to remap a bad sector during the refere…
    1.3.6.1.4.1.232.16.2.5.1.1.29 cpqFcaPhyDrvNotReadyErrs 0 0 Drive Not Ready Errors.

    The number of times the physical drive failed after the spin up
    command was issued during the reference t…
    1.3.6.1.4.1.232.16.2.5.1.1.30 cpqFcaPhyDrvHasMonInfo 0 0 Physical Drive Has Monitor Information.

    All of the physical disk table fields except for the physical
    disk status (phyDrvStatus) …
    1.3.6.1.4.1.232.16.2.5.1.1.31 cpqFcaPhyDrvCondition 0 0 The condition of the device.
    This value represents the overall condition of this physical
    drive.
    1.3.6.1.4.1.232.16.2.5.1.1.32 cpqFcaPhyDrvHotPlugs 0 0 Physical Drive Hot Plug Count.

    This value indicates the number of times this physical drive
    was hot-plugged (removed) from a stor…
    1.3.6.1.4.1.232.16.2.5.1.1.33 cpqFcaPhyDrvMediaErrs 0 0 Physical Drive Media Failure Count.

    This value indicates the number of times this physical drive
    was failed due to unrecoverable …
    1.3.6.1.4.1.232.16.2.5.1.1.34 cpqFcaPhyDrvHardwareErrs 0 0 Physical Drive Hardware Error Count.

    This value indicates the number of times this physical drive
    returned a bad hardware status.…
    1.3.6.1.4.1.232.16.2.5.1.1.35 cpqFcaPhyDrvAbortedCmds 0 0 Physical Drive Aborted Command Failures.

    This value indicates the number of times this physical drive
    was failed due to aborted c…
    1.3.6.1.4.1.232.16.2.5.1.1.36 cpqFcaPhyDrvSpinUpErrs 0 0 Physical Drive Spin-Up Failure Count.

    This value indicates the number of times this physical drive
    was failed due to a failure of…
    1.3.6.1.4.1.232.16.2.5.1.1.37 cpqFcaPhyDrvBadTargetErrs 0 0 Physical Drive Bad Target Count.

    This value indicates the number of times this physical drive
    performed some action that did not …
    1.3.6.1.4.1.232.16.2.5.1.1.38 cpqFcaPhyDrvSize 0 0 Physical Drive Size in MB.

    This is the size of the physical drive in megabytes. This value
    is calculated using the value 1,048,5…
    1.3.6.1.4.1.232.16.2.5.1.1.39 cpqFcaPhyDrvBusFaults 0 0 Physical Drive Bus Fault Count.

    This value indicates the number of times that a bus fault was
    detected for the drive by the contr…
    1.3.6.1.4.1.232.16.2.5.1.1.40 cpqFcaPhyDrvHotPlug 0 0 Physical Drive Hot Plug Support Status.

    The following values are defined:

    other(1)
    The Insight Agent is unable to determine if thi…
    1.3.6.1.4.1.232.16.2.5.1.1.41 cpqFcaPhyDrvPlacement 0 0 Physical Drive Placement.

    The following values are defined:

    other(1)
    The agent is unable to determine if the drive is internal or
    e…
    1.3.6.1.4.1.232.16.2.5.1.1.42 cpqFcaPhyDrvBusNumber 0 0 Physical Drive SCSI Bus Number.

    The bus number indicates to which SCSI bus this physical
    drive is attached. The first instance i…
    1.3.6.1.4.1.232.16.2.5.1.1.43 cpqFcaPhyDrvSerialNum 0 0 Physical Drive Serial Number.

    This is the serial number assigned to the physical drive.
    This value is based upon the serial numbe…
    1.3.6.1.4.1.232.16.2.5.1.1.44 cpqFcaPhyDrvPreFailMonitoring 0 0 Physical Drive Predictive Failure Monitoring.

    The following values are defined:

    other(1)
    The agent is unable to determine if the d…
    1.3.6.1.4.1.232.16.2.5.1.1.45 cpqFcaPhyDrvCurrentWidth 0 0 Physical Drive Current Width.

    The following values are defined:

    other(1)
    The agent is unable to determine the current negotiated d…
    1.3.6.1.4.1.232.16.2.5.1.1.46 cpqFcaPhyDrvCurrentSpeed 0 0 Physical Drive Current Data Transfer Speed.

    The following values are defined:

    other(1)
    The agent is unable to determine the curren…
    1.3.6.1.4.1.232.16.2.5.1.1.47 cpqFcaPhyDrvFailureCode 0 0 Physical Drive Failure Code.

    This value is the drive failure reason code returned by the
    array firmware. It is valid only when t…
    1.3.6.1.4.1.232.16.2.5.1.1.48 cpqFcaPhyDrvBlinkTime 0 0 Physical Drive LED Blink Time.

    This value is the amount of time remaining for the drive LEDs to
    blink in tenths of seconds. A va…
    1.3.6.1.4.1.232.16.2.5.1.1.49 cpqFcaPhyDrvSmartStatus 0 0 Physical Drive S.M.A.R.T Status.

    The following values are defined:

    other(1)
    The agent is unable to determine if the status of S.M.…
    1.3.6.1.4.1.232.16.2.5.1.1.50 cpqFcaPhyDrvRotationalSpeed 0 0 Physical Drive Rotational Speed.

    The following values are defined:

    other(1)
    The agent is unable to determine the rotational speed …
    1.3.6.1.4.1.232.16.2.5.1.1.51 cpqFcaPhyDrvType 0 0 Physical Drive Type.

    The following values are defined:

    other(1)
    The agent is unable to determine the type for this drive.

    parallelS…
    1.3.6.1.4.1.232.16.2.5.1.1.53 cpqFcaPhyDrvBoxConnector 0 0 Physical Drive Box Connector.

    This is the box connector to which the drive is ultimately
    attached. If the box connector cannot b…
    1.3.6.1.4.1.232.16.2.5.1.1.54 cpqFcaPhyDrvBoxOnConnector 0 0 Physical Drive Box on Connector.

    The box on connector indicates to which box instance this
    physical drive belongs. The instances…
    1.3.6.1.4.1.232.16.2.5.1.1.55 cpqFcaPhyDrvLocationString 0 0 Physical Drive Location String.

    This string describes the location of the drive in relation to
    the storage box. If the location …
    1.3.6.1.4.1.232.16.2.5.1.1.56 cpqFcaPhyDrvNegotiatedLinkRate 0 0 Physical Drive Negotiated Link Rate.

    The following values are defined:

    other(1)
    The agent is unable to determine the negotiated li…
    1.3.6.1.4.1.232.16.2.5.1.1.57 cpqFcaPhyDrvPhyCount 0 0 Physical Drive PHY Count.

    This value indicates how many PHYs exist on a SAS or SATA disk
    drive. If the value cannot be determine…
    1.3.6.1.4.1.232.16.2.5.1.1.58 cpqFcaPhyDrvUnsupportedDrive 0 0 Physical Drive Unsupported Drive.

    The following values are defined:

    other(1)