Reference record for OID 1.3.6.1.4.1.232.16.2.5.1.1.50



parent
1.3.6.1.4.1.232.16.2.5.1.1 (cpqFcaPhyDrvEntry)
node code
50
node name
cpqFcaPhyDrvRotationalSpeed
dot oid
1.3.6.1.4.1.232.16.2.5.1.1.50
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvRotationalSpeed(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvRotationalSpeed(50)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvRotationalSpeed(50)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvRotationalSpeed(50)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvRotationalSpeed(50)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvRotationalSpeed(50)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvRotationalSpeed(50)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaPhyDrv(5) cpqFcaPhyDrvTable(1) cpqFcaPhyDrvEntry(1) cpqFcaPhyDrvRotationalSpeed(50)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvRotationalSpeed
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvRotationalSpeed
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvRotationalSpeed
  • /iso/org/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvRotationalSpeed
  • /iso/org/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvRotationalSpeed
  • /iso/org/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvRotationalSpeed
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvRotationalSpeed
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaPhyDrv/cpqFcaPhyDrvTable/cpqFcaPhyDrvEntry/cpqFcaPhyDrvRotationalSpeed
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/16/2/5/1/1/50

    Description by mibdepot

    Physical Drive Rotational Speed.

    The following values are defined:

    other(1)
    The agent is unable to determine the rotational speed for
    this drive.

    rpm7200(2)
    The rotational speed for this drive is 7200 rpm.

    rpm10K(3)
    The rotational speed for this drive is 10000 rpm.

    rpm15K(4)
    The rotational speed for this drive is 15000 rpm.

    Parsed from file CPQFCA2.MIB.txt
    Company: None
    Module: CPQFCA-MIB

    Description by circitor

    Physical Drive Rotational Speed.

    The following values are defined:

    other(1)
    The agent is unable to determine the rotational speed for
    this drive.

    rpm7200(2)
    The rotational speed for this drive is 7200 rpm.

    rpm10K(3)
    The rotational speed for this drive is 10000 rpm.

    rpm15K(4)
    The rotational speed for this drive is 15000 rpm.

    Parsed from file CPQFCA-MIB.mib
    Module: CPQFCA-MIB

    Information by mibdepot

    cpqFcaPhyDrvRotationalSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), rpm7200(2), rpm10K(3), rpm15K(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Physical Drive Rotational Speed. The following values are defined: other(1) The agent is unable to determine the rotational speed for this drive. rpm7200(2) The rotational speed for this drive is 7200 rpm. rpm10K(3) The rotational speed for this drive is 10000 rpm. rpm15K(4) The rotational speed for this drive is 15000 rpm." ::= { cpqFcaPhyDrvEntry 50 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQFCA-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqFcaPhyDrvRotationalSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), rpm7200(2), rpm10K(3), rpm15K(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Physical Drive Rotational Speed. The following values are defined: other(1) The agent is unable to determine the rotational speed for this drive. rpm7200(2) The rotational speed for this drive is 7200 rpm. rpm10K(3) The rotational speed for this drive is 10000 rpm. rpm15K(4) The rotational speed for this drive is 15000 rpm." ::= { cpqFcaPhyDrvEntry 50 }

    Brothers (57)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.16.2.5.1.1.1 cpqFcaPhyDrvBoxIndex 0 0 External Array Physical Drive Storage Box Index.

    The storage box index indicates which storage box this physical
    drive is in.
    1.3.6.1.4.1.232.16.2.5.1.1.2 cpqFcaPhyDrvIndex 0 0 External Array Physical Drive Index.

    This index is used for selecting the physical drive table entry.
    This number, along with the…
    1.3.6.1.4.1.232.16.2.5.1.1.3 cpqFcaPhyDrvModel 0 0 External Array Physical Drive Model.

    This is a text description of the physical drive. The text that
    appears depends upon who ma…
    1.3.6.1.4.1.232.16.2.5.1.1.4 cpqFcaPhyDrvFWRev 0 0 External Array Physical Drive Firmware Revision.

    This shows the physical drive firmware revision number.
    1.3.6.1.4.1.232.16.2.5.1.1.5 cpqFcaPhyDrvBay 0 0 External Array Physical Drive Bay Location.

    This value matches the bay location where the physical drive has
    been installed. Eac…
    1.3.6.1.4.1.232.16.2.5.1.1.6 cpqFcaPhyDrvStatus 0 0 Fibre Channel Array Physical Drive Status.

    This shows the status of the physical drive.

    The following values are valid for the ph…
    1.3.6.1.4.1.232.16.2.5.1.1.7 cpqFcaPhyDrvUsedReallocs 0 0 External Array Physical Drive Used Reallocated Sectors.

    This shows the number of sectors of the reallocation area that
    have been …
    1.3.6.1.4.1.232.16.2.5.1.1.8 cpqFcaPhyDrvRefHours 0 0 External Array Reference Time in hours.

    This shows the total number of hours that a physical drive has
    been spinning since the dr…
    1.3.6.1.4.1.232.16.2.5.1.1.9 cpqFcaPhyDrvHReads 0 0 External Array Physical Drive Sectors Read (high).

    The phyDrvHReads and the phyDrvReads together shows the total
    number of sector…
    1.3.6.1.4.1.232.16.2.5.1.1.10 cpqFcaPhyDrvReads 0 0 External Array Physical Drive Sectors Read (low).

    The phyDrvHReads and the phyDrvReads together shows
    the total number of sectors…
    1.3.6.1.4.1.232.16.2.5.1.1.11 cpqFcaPhyDrvHWrites 0 0 Sectors Written (high).

    The phyDrvHWrites and the phyDrvWrites together shows the
    total number of sectors written to the physical…
    1.3.6.1.4.1.232.16.2.5.1.1.12 cpqFcaPhyDrvWrites 0 0 Sectors Written (low).

    The phyDrvHWrites and the phyDrvWrites together
    shows the total number of sectors written to the physical
    d…
    1.3.6.1.4.1.232.16.2.5.1.1.13 cpqFcaPhyDrvHSeeks 0 0 Total Seeks (high).

    The phyDrvHSeeks and the phyDrvSeeks together shows the total
    number of seek operations performed by the phys…
    1.3.6.1.4.1.232.16.2.5.1.1.14 cpqFcaPhyDrvSeeks 0 0 Total Seeks (low).

    The phyDrvHSeeks and the phyDrvSeeks together shows the total
    number of seek operations performed by the physi…
    1.3.6.1.4.1.232.16.2.5.1.1.15 cpqFcaPhyDrvHardReadErrs 0 0 Hard Read Errors.

    This shows the number of read errors that have occurred on a
    drive that could not be recovered by a physical dr…
    1.3.6.1.4.1.232.16.2.5.1.1.16 cpqFcaPhyDrvRecvReadErrs 0 0 Recovered Read Errors.

    This shows the number of read errors corrected through physical
    drive retries during the reference time (p…
    1.3.6.1.4.1.232.16.2.5.1.1.17 cpqFcaPhyDrvHardWriteErrs 0 0 Hard Write Errors.

    This shows the number of write errors that could not be recovered
    by a physical drive during the reference tim…
    1.3.6.1.4.1.232.16.2.5.1.1.18 cpqFcaPhyDrvRecvWriteErrs 0 0 Recovered Write Errors.

    This shows the number of write errors corrected through physical
    drive retries or recovered by a physical…
    1.3.6.1.4.1.232.16.2.5.1.1.19 cpqFcaPhyDrvHSeekErrs 0 0 Seek Errors (High).

    The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
    total number of times that the physical disk dr…
    1.3.6.1.4.1.232.16.2.5.1.1.20 cpqFcaPhyDrvSeekErrs 0 0 Seek Errors (low).
    The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
    total number of times that the physical disk dri…
    1.3.6.1.4.1.232.16.2.5.1.1.21 cpqFcaPhyDrvSpinupTime 0 0 Spin up Time in tenths of seconds.

    This is the time it takes for a physical drive to spin up to full
    speed.

    Disks require time to …
    1.3.6.1.4.1.232.16.2.5.1.1.22 cpqFcaPhyDrvFunctTest1 0 0 Functional Test 1.

    This provides information about a series of tests that indicate
    how well a physical drive works. These tests c…
    1.3.6.1.4.1.232.16.2.5.1.1.23 cpqFcaPhyDrvFunctTest2 0 0 Functional Test 2.

    This provides information about a series of tests that indicate
    how well a physical drive works. These tests c…
    1.3.6.1.4.1.232.16.2.5.1.1.24 cpqFcaPhyDrvFunctTest3 0 0 Functional Test 3.

    This provides information about a series of tests that indicate
    how well a physical drive works. These tests c…
    1.3.6.1.4.1.232.16.2.5.1.1.25 cpqFcaPhyDrvOtherTimeouts 0 0 Other Timeouts.

    The number of times that a physical drive did not respond with an
    interrupt within a controller-defined period of…
    1.3.6.1.4.1.232.16.2.5.1.1.26 cpqFcaPhyDrvBadRecvReads 0 0 Recovery Failed (Bad) Read Error.

    The number of times a read error occurred while performing
    Automatic Data Recovery from this ph…
    1.3.6.1.4.1.232.16.2.5.1.1.27 cpqFcaPhyDrvBadRecvWrites 0 0 Recovery Failed (Bad) Write Error.

    The number of times a write error occurred while performing
    Automatic Data Recovery from anoth…
    1.3.6.1.4.1.232.16.2.5.1.1.28 cpqFcaPhyDrvFormatErrs 0 0 Format Error.

    The number of times a format operation failed when the controller
    attempted to remap a bad sector during the refere…
    1.3.6.1.4.1.232.16.2.5.1.1.29 cpqFcaPhyDrvNotReadyErrs 0 0 Drive Not Ready Errors.

    The number of times the physical drive failed after the spin up
    command was issued during the reference t…
    1.3.6.1.4.1.232.16.2.5.1.1.30 cpqFcaPhyDrvHasMonInfo 0 0 Physical Drive Has Monitor Information.

    All of the physical disk table fields except for the physical
    disk status (phyDrvStatus) …
    1.3.6.1.4.1.232.16.2.5.1.1.31 cpqFcaPhyDrvCondition 0 0 The condition of the device.
    This value represents the overall condition of this physical
    drive.
    1.3.6.1.4.1.232.16.2.5.1.1.32 cpqFcaPhyDrvHotPlugs 0 0 Physical Drive Hot Plug Count.

    This value indicates the number of times this physical drive
    was hot-plugged (removed) from a stor…
    1.3.6.1.4.1.232.16.2.5.1.1.33 cpqFcaPhyDrvMediaErrs 0 0 Physical Drive Media Failure Count.

    This value indicates the number of times this physical drive
    was failed due to unrecoverable …
    1.3.6.1.4.1.232.16.2.5.1.1.34 cpqFcaPhyDrvHardwareErrs 0 0 Physical Drive Hardware Error Count.

    This value indicates the number of times this physical drive
    returned a bad hardware status.…
    1.3.6.1.4.1.232.16.2.5.1.1.35 cpqFcaPhyDrvAbortedCmds 0 0 Physical Drive Aborted Command Failures.

    This value indicates the number of times this physical drive
    was failed due to aborted c…
    1.3.6.1.4.1.232.16.2.5.1.1.36 cpqFcaPhyDrvSpinUpErrs 0 0 Physical Drive Spin-Up Failure Count.

    This value indicates the number of times this physical drive
    was failed due to a failure of…
    1.3.6.1.4.1.232.16.2.5.1.1.37 cpqFcaPhyDrvBadTargetErrs 0 0 Physical Drive Bad Target Count.

    This value indicates the number of times this physical drive
    performed some action that did not …
    1.3.6.1.4.1.232.16.2.5.1.1.38 cpqFcaPhyDrvSize 0 0 Physical Drive Size in MB.

    This is the size of the physical drive in megabytes. This value
    is calculated using the value 1,048,5…
    1.3.6.1.4.1.232.16.2.5.1.1.39 cpqFcaPhyDrvBusFaults 0 0 Physical Drive Bus Fault Count.

    This value indicates the number of times that a bus fault was
    detected for the drive by the contr…
    1.3.6.1.4.1.232.16.2.5.1.1.40 cpqFcaPhyDrvHotPlug 0 0 Physical Drive Hot Plug Support Status.

    The following values are defined:

    other(1)
    The Insight Agent is unable to determine if thi…
    1.3.6.1.4.1.232.16.2.5.1.1.41 cpqFcaPhyDrvPlacement 0 0 Physical Drive Placement.

    The following values are defined:

    other(1)
    The agent is unable to determine if the drive is internal or
    e…
    1.3.6.1.4.1.232.16.2.5.1.1.42 cpqFcaPhyDrvBusNumber 0 0 Physical Drive SCSI Bus Number.

    The bus number indicates to which SCSI bus this physical
    drive is attached. The first instance i…
    1.3.6.1.4.1.232.16.2.5.1.1.43 cpqFcaPhyDrvSerialNum 0 0 Physical Drive Serial Number.

    This is the serial number assigned to the physical drive.
    This value is based upon the serial numbe…
    1.3.6.1.4.1.232.16.2.5.1.1.44 cpqFcaPhyDrvPreFailMonitoring 0 0 Physical Drive Predictive Failure Monitoring.

    The following values are defined:

    other(1)
    The agent is unable to determine if the d…
    1.3.6.1.4.1.232.16.2.5.1.1.45 cpqFcaPhyDrvCurrentWidth 0 0 Physical Drive Current Width.

    The following values are defined:

    other(1)
    The agent is unable to determine the current negotiated d…
    1.3.6.1.4.1.232.16.2.5.1.1.46 cpqFcaPhyDrvCurrentSpeed 0 0 Physical Drive Current Data Transfer Speed.

    The following values are defined:

    other(1)
    The agent is unable to determine the curren…
    1.3.6.1.4.1.232.16.2.5.1.1.47 cpqFcaPhyDrvFailureCode 0 0 Physical Drive Failure Code.

    This value is the drive failure reason code returned by the
    array firmware. It is valid only when t…
    1.3.6.1.4.1.232.16.2.5.1.1.48 cpqFcaPhyDrvBlinkTime 0 0 Physical Drive LED Blink Time.

    This value is the amount of time remaining for the drive LEDs to
    blink in tenths of seconds. A va…
    1.3.6.1.4.1.232.16.2.5.1.1.49 cpqFcaPhyDrvSmartStatus 0 0 Physical Drive S.M.A.R.T Status.

    The following values are defined:

    other(1)
    The agent is unable to determine if the status of S.M.…
    1.3.6.1.4.1.232.16.2.5.1.1.51 cpqFcaPhyDrvType 0 0 Physical Drive Type.

    The following values are defined:

    other(1)
    The agent is unable to determine the type for this drive.

    parallelS…
    1.3.6.1.4.1.232.16.2.5.1.1.52 cpqFcaPhyDrvSataVersion 0 0 Physical Drive SATA Version.

    The following values are defined:

    other(1)
    The agent is unable to determine the SATA version for this…
    1.3.6.1.4.1.232.16.2.5.1.1.53 cpqFcaPhyDrvBoxConnector 0 0 Physical Drive Box Connector.

    This is the box connector to which the drive is ultimately
    attached. If the box connector cannot b…
    1.3.6.1.4.1.232.16.2.5.1.1.54 cpqFcaPhyDrvBoxOnConnector 0 0 Physical Drive Box on Connector.

    The box on connector indicates to which box instance this
    physical drive belongs. The instances…
    1.3.6.1.4.1.232.16.2.5.1.1.55 cpqFcaPhyDrvLocationString 0 0 Physical Drive Location String.

    This string describes the location of the drive in relation to
    the storage box. If the location …
    1.3.6.1.4.1.232.16.2.5.1.1.56 cpqFcaPhyDrvNegotiatedLinkRate 0 0 Physical Drive Negotiated Link Rate.

    The following values are defined:

    other(1)
    The agent is unable to determine the negotiated li…
    1.3.6.1.4.1.232.16.2.5.1.1.57 cpqFcaPhyDrvPhyCount 0 0 Physical Drive PHY Count.

    This value indicates how many PHYs exist on a SAS or SATA disk
    drive. If the value cannot be determine…
    1.3.6.1.4.1.232.16.2.5.1.1.58 cpqFcaPhyDrvUnsupportedDrive 0 0 Physical Drive Unsupported Drive.

    The following values are defined:

    other(1)
    The agent is unable to determine the value for this d…