Seconds delay after the Outlet is signaled to turn On before the Output is
Automatically turned ON. A value of -1 means that this Output should never
be turned On automatically, but only when specifically commanded to do so.
A value of 0 means that the Receptacle should come On immediately
at power-up or for an On command.
Parsed from file CPQPOWER1.62.MIB.txt
Company: None
Module: CPQPOWER-MIB
Seconds delay after the Outlet is signaled to turn On before the Output is
Automatically turned ON. A value of -1 means that this Output should never
be turned On automatically, but only when specifically commanded to do so.
A value of 0 means that the Receptacle should come On immediately
at power-up or for an On command.
Parsed from file CPQPOWER-MIB.mib
Module: CPQPOWER-MIB
upsRecepAutoOnDelay OBJECT-TYPE SYNTAX INTEGER (-1..32767) ACCESS read-write STATUS mandatory DESCRIPTION "Seconds delay after the Outlet is signaled to turn On before the Output is Automatically turned ON. A value of -1 means that this Output should never be turned On automatically, but only when specifically commanded to do so. A value of 0 means that the Receptacle should come On immediately at power-up or for an On command." ::= { upsRecepEntry 6 }
Vendor: Compaq
Module: CPQPOWER-MIB
[Automatically extracted from oidview.com]
upsRecepAutoOnDelay OBJECT-TYPE SYNTAX INTEGER (-1..32767) ACCESS read-write STATUS mandatory DESCRIPTION "Seconds delay after the Outlet is signaled to turn On before the Output is Automatically turned ON. A value of -1 means that this Output should never be turned On automatically, but only when specifically commanded to do so. A value of 0 means that the Receptacle should come On immediately at power-up or for an On command." ::= { upsRecepEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.165.3.10.2.1.1 | upsRecepIndex | 0 | 0 | The number of the Receptacle. Serves as index for Receptacle table. |
1.3.6.1.4.1.232.165.3.10.2.1.2 | upsRecepStatus | 0 | 0 | The Recep Status 1=On/Close, 2=Off/Open, 3=On w/Pending Off, 4=Off w/Pending ON, 5=Unknown. |
1.3.6.1.4.1.232.165.3.10.2.1.3 | upsRecepOffDelaySecs | 0 | 0 | The Delay until the Receptacle is turned Off. Setting this value to other than -1 will cause the UPS output to turn off after th… |
1.3.6.1.4.1.232.165.3.10.2.1.4 | upsRecepOnDelaySecs | 0 | 0 | The Delay until the Receptacle is turned On. Setting this value to other than -1 will cause the UPS output to turn on after the … |
1.3.6.1.4.1.232.165.3.10.2.1.5 | upsRecepAutoOffDelay | 0 | 0 | The delay after going On Battery until the Receptacle is automatically turned Off. A value of -1 means that this Output should n… |
1.3.6.1.4.1.232.165.3.10.2.1.7 | upsRecepShedSecsWithRestart | 0 | 0 | Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down… |