Reference record for OID 1.3.6.1.4.1.232.5.5.3.1.1.12



parent
1.3.6.1.4.1.232.5.5.3.1.1 (cpqSasLogDrvEntry)
node code
12
node name
cpqSasLogDrvRebuildingPercent
dot oid
1.3.6.1.4.1.232.5.5.3.1.1.12
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqScsi(5) cpqSasComponent(5) cpqSasLogDrv(3) cpqSasLogDrvTable(1) cpqSasLogDrvEntry(1) cpqSasLogDrvRebuildingPercent(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqScsi(5) cpqSasComponent(5) cpqSasLogDrv(3) cpqSasLogDrvTable(1) cpqSasLogDrvEntry(1) cpqSasLogDrvRebuildingPercent(12)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqScsi(5) cpqSasComponent(5) cpqSasLogDrv(3) cpqSasLogDrvTable(1) cpqSasLogDrvEntry(1) cpqSasLogDrvRebuildingPercent(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqScsi(5) cpqSasComponent(5) cpqSasLogDrv(3) cpqSasLogDrvTable(1) cpqSasLogDrvEntry(1) cpqSasLogDrvRebuildingPercent(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqScsi(5) cpqSasComponent(5) cpqSasLogDrv(3) cpqSasLogDrvTable(1) cpqSasLogDrvEntry(1) cpqSasLogDrvRebuildingPercent(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqScsi(5) cpqSasComponent(5) cpqSasLogDrv(3) cpqSasLogDrvTable(1) cpqSasLogDrvEntry(1) cpqSasLogDrvRebuildingPercent(12)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqScsi(5) cpqSasComponent(5) cpqSasLogDrv(3) cpqSasLogDrvTable(1) cpqSasLogDrvEntry(1) cpqSasLogDrvRebuildingPercent(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqScsi(5) cpqSasComponent(5) cpqSasLogDrv(3) cpqSasLogDrvTable(1) cpqSasLogDrvEntry(1) cpqSasLogDrvRebuildingPercent(12)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqScsi/cpqSasComponent/cpqSasLogDrv/cpqSasLogDrvTable/cpqSasLogDrvEntry/cpqSasLogDrvRebuildingPercent
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqScsi/cpqSasComponent/cpqSasLogDrv/cpqSasLogDrvTable/cpqSasLogDrvEntry/cpqSasLogDrvRebuildingPercent
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqScsi/cpqSasComponent/cpqSasLogDrv/cpqSasLogDrvTable/cpqSasLogDrvEntry/cpqSasLogDrvRebuildingPercent
  • /iso/org/dod/internet/private/enterprise/hp/cpqScsi/cpqSasComponent/cpqSasLogDrv/cpqSasLogDrvTable/cpqSasLogDrvEntry/cpqSasLogDrvRebuildingPercent
  • /iso/org/dod/internet/private/enterprises/compaq/cpqScsi/cpqSasComponent/cpqSasLogDrv/cpqSasLogDrvTable/cpqSasLogDrvEntry/cpqSasLogDrvRebuildingPercent
  • /iso/org/dod/internet/private/enterprises/hp/cpqScsi/cpqSasComponent/cpqSasLogDrv/cpqSasLogDrvTable/cpqSasLogDrvEntry/cpqSasLogDrvRebuildingPercent
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqScsi/cpqSasComponent/cpqSasLogDrv/cpqSasLogDrvTable/cpqSasLogDrvEntry/cpqSasLogDrvRebuildingPercent
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqScsi/cpqSasComponent/cpqSasLogDrv/cpqSasLogDrvTable/cpqSasLogDrvEntry/cpqSasLogDrvRebuildingPercent
  • Description by mibdepot

    Logical Drive Percent Rebuild.

    After a failed physical drive has been replaced, the physical
    drive must have its data rebuilt. This value is the percent
    complete of the rebuild. When the value reaches 100, the
    rebuilding process is complete. The array continues to
    operate in interim recovery mode while the disk is rebuilding.

    This value is only valid if the Logical Drive Status is
    rebuilding(4).

    If the value cannot be determined or a rebuild is not active,
    the value is set to 4,294,967,295.

    Parsed from file CPQSCSI1.MIB.txt
    Company: compaq
    Module: CPQSCSI-MIB

    Information by mibdepot

    cpqSasLogDrvRebuildingPercent OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value is the percent complete of the rebuild. When the value reaches 100, the rebuilding process is complete. The array continues to operate in interim recovery mode while the disk is rebuilding. This value is only valid if the Logical Drive Status is rebuilding(4). If the value cannot be determined or a rebuild is not active, the value is set to 4,294,967,295." ::= { cpqSasLogDrvEntry 12 }

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.5.5.3.1.1.1 cpqSasLogDrvHbaIndex 0 0 SAS Logical Drive HBA Index.

    The controller index indicates to which SAS adapter instance
    this table entry belongs.
    1.3.6.1.4.1.232.5.5.3.1.1.2 cpqSasLogDrvIndex 0 0 SAS Logical Drive Index.

    The logical drive index indicates to which logical drive instance
    this table entry belongs.
    1.3.6.1.4.1.232.5.5.3.1.1.3 cpqSasLogDrvRaidLevel 0 0 SAS Logical Drive RAID Level.

    The following RAID levels are defined:

    other(1)
    The agent cannot determine the RAID level of this lo…
    1.3.6.1.4.1.232.5.5.3.1.1.4 cpqSasLogDrvStatus 0 0 SAS Logical Drive Status.

    The logical drive can be in one of the following states:

    other(1)
    The management agent does not recogniz…
    1.3.6.1.4.1.232.5.5.3.1.1.5 cpqSasLogDrvCondition 0 0 SAS Logical Drive Condition.

    This is the condition of the logical drive.
    1.3.6.1.4.1.232.5.5.3.1.1.6 cpqSasLogDrvRebuildingDisk 0 0 SAS Logical Drive Rebuilding Disk.

    This is the disk that is in the process of rebuilding. If no
    drive is currently rebuilding, a…
    1.3.6.1.4.1.232.5.5.3.1.1.7 cpqSasLogDrvCapacity 0 0 SAS Logical Drive Size.

    This is the capacity of the logical drive in megabytes.
    This value is calculated using the value 1,048,57…
    1.3.6.1.4.1.232.5.5.3.1.1.8 cpqSasLogDrvStripeSize 0 0 SAS Logical Drive Stripe Size.

    This is the size of a logical drive stripe in kilobytes.
    1.3.6.1.4.1.232.5.5.3.1.1.9 cpqSasLogDrvPhyDrvIds 0 0 SAS Logical Drive Physical Drive IDs.

    This lists the physical drive ID's associated with this logical
    drive. Each 4 octets of th…
    1.3.6.1.4.1.232.5.5.3.1.1.10 cpqSasLogDrvSpareIds 0 0 SAS Logical Drive Spare Drive IDs.

    This lists the spare drive ID's associated with this logical
    drive. Each 4 octets of the stri…
    1.3.6.1.4.1.232.5.5.3.1.1.11 cpqSasLogDrvOsName 0 0 SAS Logical Drive OS Name.

    This is the OS name for the logical drive. This field will be