SAS Logical Drive Status.
The logical drive can be in one of the following states:
other(1)
The management agent does not recognize the status.
You may need to upgrade your software.
ok(2)
Indicates that the logical drive is in normal operation mode.
No user action is required.
degraded(3)
Indicates that the logical drive is in a degraded state.
rebuilding(4)
Indicates that the logical drive is currently resynchronizing
the data accross the physical drives in the logical drive.
failed(5)
Indicates that more physical drives have failed than the
fault tolerance mode of the logical drive can handle without
data loss.
offline(6)
Indicates that the logical drive is offline from the operating
system. User action may be required to bring the logical
drive online.
Parsed from file CPQSCSI1.MIB.txt
Company: compaq
Module: CPQSCSI-MIB
cpqSasLogDrvStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), rebuilding(4), failed(5), offline(6) } ACCESS read-only STATUS mandatory DESCRIPTION "SAS Logical Drive Status. The logical drive can be in one of the following states: other(1) The management agent does not recognize the status. You may need to upgrade your software. ok(2) Indicates that the logical drive is in normal operation mode. No user action is required. degraded(3) Indicates that the logical drive is in a degraded state. rebuilding(4) Indicates that the logical drive is currently resynchronizing the data accross the physical drives in the logical drive. failed(5) Indicates that more physical drives have failed than the fault tolerance mode of the logical drive can handle without data loss. offline(6) Indicates that the logical drive is offline from the operating system. User action may be required to bring the logical drive online." ::= { cpqSasLogDrvEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.5.5.3.1.1.1 | cpqSasLogDrvHbaIndex | 0 | 0 | SAS Logical Drive HBA Index. The controller index indicates to which SAS adapter instance this table entry belongs. |
1.3.6.1.4.1.232.5.5.3.1.1.2 | cpqSasLogDrvIndex | 0 | 0 | SAS Logical Drive Index. The logical drive index indicates to which logical drive instance this table entry belongs. |
1.3.6.1.4.1.232.5.5.3.1.1.3 | cpqSasLogDrvRaidLevel | 0 | 0 | SAS Logical Drive RAID Level. The following RAID levels are defined: other(1) The agent cannot determine the RAID level of this lo… |
1.3.6.1.4.1.232.5.5.3.1.1.5 | cpqSasLogDrvCondition | 0 | 0 | SAS Logical Drive Condition. This is the condition of the logical drive. |
1.3.6.1.4.1.232.5.5.3.1.1.6 | cpqSasLogDrvRebuildingDisk | 0 | 0 | SAS Logical Drive Rebuilding Disk. This is the disk that is in the process of rebuilding. If no drive is currently rebuilding, a… |
1.3.6.1.4.1.232.5.5.3.1.1.7 | cpqSasLogDrvCapacity | 0 | 0 | SAS Logical Drive Size. This is the capacity of the logical drive in megabytes. This value is calculated using the value 1,048,57… |
1.3.6.1.4.1.232.5.5.3.1.1.8 | cpqSasLogDrvStripeSize | 0 | 0 | SAS Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes. |
1.3.6.1.4.1.232.5.5.3.1.1.9 | cpqSasLogDrvPhyDrvIds | 0 | 0 | SAS Logical Drive Physical Drive IDs. This lists the physical drive ID's associated with this logical drive. Each 4 octets of th… |
1.3.6.1.4.1.232.5.5.3.1.1.10 | cpqSasLogDrvSpareIds | 0 | 0 | SAS Logical Drive Spare Drive IDs. This lists the spare drive ID's associated with this logical drive. Each 4 octets of the stri… |
1.3.6.1.4.1.232.5.5.3.1.1.11 | cpqSasLogDrvOsName | 0 | 0 | SAS Logical Drive OS Name. This is the OS name for the logical drive. This field will be a null (size 0) string if the agent doe… |
1.3.6.1.4.1.232.5.5.3.1.1.12 | cpqSasLogDrvRebuildingPercent | 0 | 0 | Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. T… |