SAS Logical Drive Size.
This is the capacity of the logical drive in megabytes.
This value is calculated using the value 1,048,576 (2^20) as
a megabyte. Drive manufacturers sometimes use the
number 1,000,000 as a megabyte when giving drive capacities
so this value may differ from the advertised size of a drive.
Parsed from file CPQSCSI1.MIB.txt
Company: compaq
Module: CPQSCSI-MIB
cpqSasLogDrvCapacity OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "SAS Logical Drive Size. This is the capacity of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may differ from the advertised size of a drive." ::= { cpqSasLogDrvEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.5.5.3.1.1.1 | cpqSasLogDrvHbaIndex | 0 | 0 | SAS Logical Drive HBA Index. The controller index indicates to which SAS adapter instance this table entry belongs. |
1.3.6.1.4.1.232.5.5.3.1.1.2 | cpqSasLogDrvIndex | 0 | 0 | SAS Logical Drive Index. The logical drive index indicates to which logical drive instance this table entry belongs. |
1.3.6.1.4.1.232.5.5.3.1.1.3 | cpqSasLogDrvRaidLevel | 0 | 0 | SAS Logical Drive RAID Level. The following RAID levels are defined: other(1) The agent cannot determine the RAID level of this lo… |
1.3.6.1.4.1.232.5.5.3.1.1.4 | cpqSasLogDrvStatus | 0 | 0 | SAS Logical Drive Status. The logical drive can be in one of the following states: other(1) The management agent does not recogniz… |
1.3.6.1.4.1.232.5.5.3.1.1.5 | cpqSasLogDrvCondition | 0 | 0 | SAS Logical Drive Condition. This is the condition of the logical drive. |
1.3.6.1.4.1.232.5.5.3.1.1.6 | cpqSasLogDrvRebuildingDisk | 0 | 0 | SAS Logical Drive Rebuilding Disk. This is the disk that is in the process of rebuilding. If no drive is currently rebuilding, a… |
1.3.6.1.4.1.232.5.5.3.1.1.8 | cpqSasLogDrvStripeSize | 0 | 0 | SAS Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes. |
1.3.6.1.4.1.232.5.5.3.1.1.9 | cpqSasLogDrvPhyDrvIds | 0 | 0 | SAS Logical Drive Physical Drive IDs. This lists the physical drive ID's associated with this logical drive. Each 4 octets of th… |
1.3.6.1.4.1.232.5.5.3.1.1.10 | cpqSasLogDrvSpareIds | 0 | 0 | SAS Logical Drive Spare Drive IDs. This lists the spare drive ID's associated with this logical drive. Each 4 octets of the stri… |
1.3.6.1.4.1.232.5.5.3.1.1.11 | cpqSasLogDrvOsName | 0 | 0 | SAS Logical Drive OS Name. This is the OS name for the logical drive. This field will be a null (size 0) string if the agent doe… |
1.3.6.1.4.1.232.5.5.3.1.1.12 | cpqSasLogDrvRebuildingPercent | 0 | 0 | Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. T… |