Status of 2.5VA power.
Possible Values:
Alert: Voltage 2.5 VA: Voltage out of range;
This is the voltage supplied to the primary processor.
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel Networks representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.
Parsed from file cesTraps.mib.txt
Company: None
Module: CONTIVITY-TRAPS-V1-MIB
Status of 2.5VA power.
Possible Values:
Alert: Voltage 2.5 VA: Voltage out of range;
This is the voltage supplied to the primary processor.
The supplied voltage to the system is not within the
the specified range for that particular voltage.
Certain platforms do not supply or monitor some of
these voltages. See the Health Check section of the
Admin Guide for a description of which platforms monitor
which voltages.
This is a major problem and the box should be looked
at by a qualified Nortel Networks representative as
soon as possible. Correct operation of the system
is not guaranteed while in this state. Certain platforms
do not supply or monitor some of these voltages.
See the Health Check section of the Admin Guide for a
description of which platforms monitor which voltages.
Parsed from file CONTIVITY-TRAPS-V1-MIB.mib
Module: CONTIVITY-TRAPS-V1-MIB
Vendor: New Oak Communications, Inc.
Module: CONTIVITY-TRAPS-V1-MIB
[Automatically extracted from oidview.com]
twoDotFiveVA OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Status of 2.5VA power. Possible Values: Alert: Voltage 2.5 VA: Voltage out of range; This is the voltage supplied to the primary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages." ::= {hardwareCESTrapInfo 12}
twoDotFiveVA OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Status of 2.5VA power. Possible Values: Alert: Voltage 2.5 VA: Voltage out of range; This is the voltage supplied to the primary processor. The supplied voltage to the system is not within the the specified range for that particular voltage. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages. This is a major problem and the box should be looked at by a qualified Nortel Networks representative as soon as possible. Correct operation of the system is not guaranteed while in this state. Certain platforms do not supply or monitor some of these voltages. See the Health Check section of the Admin Guide for a description of which platforms monitor which voltages." ::= {hardwareCESTrapInfo 12}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2505.1.1.12.0 | twoDotFiveVA | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2505.1.1.1 | hardDisk1Status | 1 | 1 | Hard Disk Number 1 Status. Possible Values: Warning: Hard Disk 1 : Device /ide1/ not available Warning: Hard Disk 1 : Utilization … |
1.3.6.1.4.1.2505.1.1.2 | hardDisk0Status | 1 | 1 | Hard Disk Number 0 Status. Possible Values: Warning: Hard Disk 0 : Device /ide0/ not available Warning: Hard Disk 0 : Utilization … |
1.3.6.1.4.1.2505.1.1.3 | memoryUsage | 1 | 1 | Memory Usage Status. Possible Values: Warning: Memory Usage : Utilization exceeds 75% Alert: Memory Usage : Utilization exceeds 87… |
1.3.6.1.4.1.2505.1.1.4 | lanCardStatus | 1 | 1 | Status of any LAN cards on the system. Possible Values: Please note that X corresponds to the Xth slot in the system. Please note … |
1.3.6.1.4.1.2505.1.1.5 | cpuTwoStatus | 1 | 1 | Status of second CPU. Possible Values: Alert: CPU 2: Program load failed; Alert: CPU 2: Bootup did not complete; Alert: CPU 2: Comm… |
1.3.6.1.4.1.2505.1.1.6 | fanOneStatus | 1 | 1 | Status of the first CPU fan. Possible Values: Alert: CPU One Fan: Fan not functioning; This indicates that the fan on the primary … |
1.3.6.1.4.1.2505.1.1.7 | fanTwoStatus | 1 | 1 | Status of the second CPU fan Possible Values: Alert: CPU Two Fan: Fan not functioning; This indicates that the fan on the auxiliar… |
1.3.6.1.4.1.2505.1.1.8 | chassisFanStatus | 1 | 1 | Status of the chassis fan. Possible Values: Alert: Chassis Fan: Fan not functioning; Alert: Chassis Fan 2: Fan not functioning; Thi… |
1.3.6.1.4.1.2505.1.1.9 | fiveVoltsPositive | 1 | 1 | Status of +5 Volt power. Possible Values: Alert: Voltage 5 V Plus: Voltage out of range; The supplied voltage to the system is not… |
1.3.6.1.4.1.2505.1.1.10 | fiveVoltsMinus | 1 | 1 | Status of -5 Volt power. Possible Values: Alert: Voltage 5 V Minus: Voltage out of range; The supplied voltage to the system is no… |
1.3.6.1.4.1.2505.1.1.11 | threeVoltsPositive | 1 | 1 | Status of +3 Volt power. Possible Values: Alert: Voltage 3.3 V Plus: Voltage out of range; The supplied voltage to the system is n… |
1.3.6.1.4.1.2505.1.1.13 | twoDotFiveVB | 1 | 1 | Status of 2.5VB power. Possible Values: Alert: Voltage 2.5 VB: Voltage out of range; This is the voltage supplied to the seconary … |
1.3.6.1.4.1.2505.1.1.14 | twelveVoltsPositive | 1 | 1 | Status of +12 Volt power. Possible Values: Alert: Voltage 12 V Plus: Voltage out of range; The supplied voltage to the system is n… |
1.3.6.1.4.1.2505.1.1.15 | twelveVoltsMinus | 1 | 1 | Status of -12 Volt power. Possible Values: Alert: Voltage 12 V Minus: Voltage out of range; The supplied voltage to the system is … |
1.3.6.1.4.1.2505.1.1.16 | normalTemperature | 1 | 1 | Status of normal temperature reading. Possible Values: Alert: Normal Temperature: Normal temperature out of range; This indicates … |
1.3.6.1.4.1.2505.1.1.17 | criticalTemperature | 1 | 1 | Status of critical temperature reading. Possible Values: Alert: Critical Temperature: Critial temperature out of range; This indic… |
1.3.6.1.4.1.2505.1.1.18 | chassisIntrusion | 1 | 1 | The chassis intrusion sensor indicates that the unit has been opened. Possible Values: Alert: Intrusion: Box has been opened; The … |
1.3.6.1.4.1.2505.1.1.19 | dualPowerSupply | 1 | 1 | Status of the redundant power supplies. Possible Values: Alert: Dual Power Supply: Redundant supply faulted This indicates that, o… |
1.3.6.1.4.1.2505.1.1.20 | t1WANStatus | 1 | 1 | Status of T1 WAN card(s). Possible Values: For Wanic support: Alert: Invalid Device X Warning: Device WanicX disabled Alert: Device … |
1.3.6.1.4.1.2505.1.1.21 | t3WANStatus | 1 | 1 | Status of T3 WAN card Possible Values: Alert: Invalid Index X Warning: Device HSSIX disabled Alert: Device HSSIX down Warning: Devic… |
1.3.6.1.4.1.2505.1.1.22 | hwAccelStatus | 1 | 1 | Status of hardware accelerator card. |
1.3.6.1.4.1.2505.1.1.24 | v90WANStatus | 1 | 1 | Status of V.90 Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: V.90 Invalid … |
1.3.6.1.4.1.2505.1.1.25 | briWANStatus | 1 | 1 | Status of ISDN BRI Interface card Possible Values: Please note that X corresponds to the unit number of the card. Alert: BRI Inval… |
1.3.6.1.4.1.2505.1.1.26 | serUartStatus | 1 | 1 | Status of Serial (COM) port/interface Possible Values: Please note that X corresponds to the unit number of the serial interface A… |
1.3.6.1.4.1.2505.1.1.27 | adslWANStatus | 1 | 1 | Status of ADI ADSL card Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: Invalid … |
1.3.6.1.4.1.2505.1.1.1001 | hardDisk1StatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.1002 | hardDisk0StatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.1003 | memoryUsageTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.1004 | lanCardStatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.1005 | cpuTwoStatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.1006 | fanOneStatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.1007 | fanTwoStatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.1008 | chassisFanStatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.1009 | fiveVoltsPosStatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10010 | fiveVoltsMinusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10011 | threeVoltsPositiveTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10012 | twoDotFiveVATrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10013 | twoDotFiveVBTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10014 | twelveVoltsPositveTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10015 | twelveVoltsMinsTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10016 | normalTemperatureTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10017 | criticalTemperatureTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10018 | chassisIntrusionTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10019 | dualPowerSupplyTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10020 | t1WANStatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10021 | t3WANStatusTrap | 0 | 0 | None |
1.3.6.1.4.1.2505.1.1.10022 | hwAccelTrap | 0 | 0 | None |