Reference record for OID 1.3.6.1.4.1.2505.1.1.26


parent
1.3.6.1.4.1.2505.1.1 (hardwareCESTrapInfo)
node code
26
node name
serUartStatus
dot oid
1.3.6.1.4.1.2505.1.1.26
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) serUartStatus(26)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) serUartStatus(26)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) serUartStatus(26)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) serUartStatus(26)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) serUartStatus(26)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) serUartStatus(26)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/newoak/contivity/hardwareCESTrapInfo/serUartStatus
  • /iso/identified-organization/dod/internet/private/enterprises/newoak/contivity/hardwareCESTrapInfo/serUartStatus
  • /iso/org/dod/internet/private/enterprise/newoak/contivity/hardwareCESTrapInfo/serUartStatus
  • /iso/org/dod/internet/private/enterprises/newoak/contivity/hardwareCESTrapInfo/serUartStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprise/newoak/contivity/hardwareCESTrapInfo/serUartStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/newoak/contivity/hardwareCESTrapInfo/serUartStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2505/1/1/26

    Description by mibdepot

    Status of Serial (COM) port/interface
    Possible Values:
    Please note that X corresponds to the unit number of the serial interface
    Alert: COM port Invalid index X
    Healthy: Device COMX is set for Serial Menu.
    Disabled: Device COMX disabled
    Warning: Device COMX not initialized
    Healthy: Device COMX: PPP is UP.
    Alert: Device COMX: Call is UP. Internal Error.
    Warning: Device COMX is Down. Last dial-out attempt FAILED.
    Healthy: Device COMX is Down (No Active calls)
    Alert: Device COMX is in an UNKNOWN state

    Parsed from file cesTraps.mib.txt
    Company: nortel
    Module: CONTIVITY-TRAPS-V1-MIB

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    serUartStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Status of Serial (COM) port/interface Possible Values: Please note that X corresponds to the unit number of the serial interface Alert: COM port Invalid index X Healthy: Device COMX is set for Serial Menu. Disabled: Device COMX disabled Warning: Device COMX not initialized Healthy: Device COMX: PPP is UP. Alert: Device COMX: Call is UP. Internal Error. Warning: Device COMX is Down. Last dial-out attempt FAILED. Healthy: Device COMX is Down (No Active calls) Alert: Device COMX is in an UNKNOWN state" ::= {hardwareCESTrapInfo 26}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2505)

    Philippou Jim

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2505.1.1.26.0 serUartStatus 0 0 None

    Brothers (47)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2505.1.1.1 hardDisk1Status 1 1 Hard Disk Number 1 Status.
    Possible Values:
    Warning: Hard Disk 1 : Device /ide1/ not available
    Warning: Hard Disk 1 : Utilization …
    1.3.6.1.4.1.2505.1.1.2 hardDisk0Status 1 1 Hard Disk Number 0 Status.
    Possible Values:
    Warning: Hard Disk 0 : Device /ide0/ not available
    Warning: Hard Disk 0 : Utilization …
    1.3.6.1.4.1.2505.1.1.3 memoryUsage 1 1 Memory Usage Status.
    Possible Values:
    Warning: Memory Usage : Utilization exceeds 75%
    Alert: Memory Usage : Utilization exceeds 87…
    1.3.6.1.4.1.2505.1.1.4 lanCardStatus 1 1 Status of any LAN cards on the system.
    Possible Values:
    Please note that X corresponds to the Xth slot in the system.
    Please note …
    1.3.6.1.4.1.2505.1.1.5 cpuTwoStatus 1 1 Status of second CPU.
    Possible Values:
    Alert: CPU 2: Program load failed;
    Alert: CPU 2: Bootup did not complete;
    Alert: CPU 2: Comm…
    1.3.6.1.4.1.2505.1.1.6 fanOneStatus 1 1 Status of the first CPU fan.
    Possible Values:
    Alert: CPU One Fan: Fan not functioning;

    This indicates that the fan on the primary …
    1.3.6.1.4.1.2505.1.1.7 fanTwoStatus 1 1 Status of the second CPU fan
    Possible Values:
    Alert: CPU Two Fan: Fan not functioning;

    This indicates that the fan on the auxiliar…
    1.3.6.1.4.1.2505.1.1.8 chassisFanStatus 1 1 Status of the chassis fan.
    Possible Values:
    Alert: Chassis Fan: Fan not functioning;
    Alert: Chassis Fan 2: Fan not functioning;

    Thi…
    1.3.6.1.4.1.2505.1.1.9 fiveVoltsPositive 1 1 Status of +5 Volt power.
    Possible Values:
    Alert: Voltage 5 V Plus: Voltage out of range;

    The supplied voltage to the system is not…
    1.3.6.1.4.1.2505.1.1.10 fiveVoltsMinus 1 1 Status of -5 Volt power.
    Possible Values:
    Alert: Voltage 5 V Minus: Voltage out of range;

    The supplied voltage to the system is no…
    1.3.6.1.4.1.2505.1.1.11 threeVoltsPositive 1 1 Status of +3 Volt power.
    Possible Values:
    Alert: Voltage 3.3 V Plus: Voltage out of range;

    The supplied voltage to the system is n…
    1.3.6.1.4.1.2505.1.1.12 twoDotFiveVA 1 1 Status of 2.5VA power.
    Possible Values:
    Alert: Voltage 2.5 VA: Voltage out of range;

    This is the voltage supplied to the primary p…
    1.3.6.1.4.1.2505.1.1.13 twoDotFiveVB 1 1 Status of 2.5VB power.
    Possible Values:
    Alert: Voltage 2.5 VB: Voltage out of range;

    This is the voltage supplied to the seconary …
    1.3.6.1.4.1.2505.1.1.14 twelveVoltsPositive 1 1 Status of +12 Volt power.
    Possible Values:
    Alert: Voltage 12 V Plus: Voltage out of range;

    The supplied voltage to the system is n…
    1.3.6.1.4.1.2505.1.1.15 twelveVoltsMinus 1 1 Status of -12 Volt power.
    Possible Values:
    Alert: Voltage 12 V Minus: Voltage out of range;

    The supplied voltage to the system is …
    1.3.6.1.4.1.2505.1.1.16 normalTemperature 1 1 Status of normal temperature reading.
    Possible Values:
    Alert: Normal Temperature: Normal temperature out of range;

    This indicates …
    1.3.6.1.4.1.2505.1.1.17 criticalTemperature 1 1 Status of critical temperature reading.
    Possible Values:
    Alert: Critical Temperature: Critial temperature out of range;

    This indic…
    1.3.6.1.4.1.2505.1.1.18 chassisIntrusion 1 1 The chassis intrusion sensor indicates that the unit has been opened.

    Possible Values:
    Alert: Intrusion: Box has been opened;

    The …
    1.3.6.1.4.1.2505.1.1.19 dualPowerSupply 1 1 Status of the redundant power supplies.
    Possible Values:
    Alert: Dual Power Supply: Redundant supply faulted

    This indicates that, o…
    1.3.6.1.4.1.2505.1.1.20 t1WANStatus 1 1 Status of T1 WAN card(s).
    Possible Values:
    For Wanic support:
    Alert: Invalid Device X
    Warning: Device WanicX disabled
    Alert: Device …
    1.3.6.1.4.1.2505.1.1.21 t3WANStatus 1 1 Status of T3 WAN card
    Possible Values:
    Alert: Invalid Index X
    Warning: Device HSSIX disabled
    Alert: Device HSSIX down
    Warning: Devic…
    1.3.6.1.4.1.2505.1.1.22 hwAccelStatus 1 1 Status of hardware accelerator card.
    1.3.6.1.4.1.2505.1.1.24 v90WANStatus 1 1 Status of V.90 Interface card
    Possible Values:
    Please note that X corresponds to the unit number of the card.
    Alert: V.90 Invalid …
    1.3.6.1.4.1.2505.1.1.25 briWANStatus 1 1 Status of ISDN BRI Interface card
    Possible Values:
    Please note that X corresponds to the unit number of the card.
    Alert: BRI Inval…
    1.3.6.1.4.1.2505.1.1.27 adslWANStatus 1 1 Status of ADI ADSL card
    Possible Values:
    Please note that X corresponds to the unit number of the serial interface
    Alert: Invalid …
    1.3.6.1.4.1.2505.1.1.1001 hardDisk1StatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1002 hardDisk0StatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1003 memoryUsageTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1004 lanCardStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1005 cpuTwoStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1006 fanOneStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1007 fanTwoStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1008 chassisFanStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1009 fiveVoltsPosStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10010 fiveVoltsMinusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10011 threeVoltsPositiveTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10012 twoDotFiveVATrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10013 twoDotFiveVBTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10014 twelveVoltsPositveTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10015 twelveVoltsMinsTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10016 normalTemperatureTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10017 criticalTemperatureTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10018 chassisIntrusionTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10019 dualPowerSupplyTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10020 t1WANStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10021 t3WANStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10022 hwAccelTrap 0 0 None