Reference record for OID 1.3.6.1.4.1.2505.1.1.7


parent
1.3.6.1.4.1.2505.1.1 (hardwareCESTrapInfo)
node code
7
node name
fanTwoStatus
dot oid
1.3.6.1.4.1.2505.1.1.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) fanTwoStatus(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) fanTwoStatus(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) fanTwoStatus(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) fanTwoStatus(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) fanTwoStatus(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newoak(2505) contivity(1) hardwareCESTrapInfo(1) fanTwoStatus(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/newoak/contivity/hardwareCESTrapInfo/fanTwoStatus
  • /iso/identified-organization/dod/internet/private/enterprises/newoak/contivity/hardwareCESTrapInfo/fanTwoStatus
  • /iso/org/dod/internet/private/enterprise/newoak/contivity/hardwareCESTrapInfo/fanTwoStatus
  • /iso/org/dod/internet/private/enterprises/newoak/contivity/hardwareCESTrapInfo/fanTwoStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprise/newoak/contivity/hardwareCESTrapInfo/fanTwoStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/newoak/contivity/hardwareCESTrapInfo/fanTwoStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2505/1/1/7

    Description by mibdepot

    Status of the second CPU fan
    Possible Values:
    Alert: CPU Two Fan: Fan not functioning;

    This indicates that the fan on the auxiliary processor is
    running either below the specified speed or not running
    at all. If a fan is not working correctly, it must be
    fixed as soon as possible or damage may result.

    This is a high priority event which can prove catastrophic
    to the processor as well as the system. This trap can only
    be sent by systems which contain an actual fan on the
    auxiliary CPU.

    Parsed from file cesTraps.mib.txt
    Company: None
    Module: CONTIVITY-TRAPS-V1-MIB

    Description by circitor

    Status of the second CPU fan
    Possible Values:
    Alert: CPU Two Fan: Fan not functioning;

    This indicates that the fan on the auxiliary processor is
    running either below the specified speed or not running
    at all. If a fan is not working correctly, it must be
    fixed as soon as possible or damage may result.

    This is a high priority event which can prove catastrophic
    to the processor as well as the system. This trap can only
    be sent by systems which contain an actual fan on the
    auxiliary CPU.

    Parsed from file CONTIVITY-TRAPS-V1-MIB.mib
    Module: CONTIVITY-TRAPS-V1-MIB

    Information by oid_info

    Vendor: New Oak Communications, Inc.
    Module: CONTIVITY-TRAPS-V1-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    fanTwoStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Status of the second CPU fan Possible Values: Alert: CPU Two Fan: Fan not functioning; This indicates that the fan on the auxiliary processor is running either below the specified speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. This is a high priority event which can prove catastrophic to the processor as well as the system. This trap can only be sent by systems which contain an actual fan on the auxiliary CPU." ::= {hardwareCESTrapInfo 7}

    Information by circitor

    fanTwoStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Status of the second CPU fan Possible Values: Alert: CPU Two Fan: Fan not functioning; This indicates that the fan on the auxiliary processor is running either below the specified speed or not running at all. If a fan is not working correctly, it must be fixed as soon as possible or damage may result. This is a high priority event which can prove catastrophic to the processor as well as the system. This trap can only be sent by systems which contain an actual fan on the auxiliary CPU." ::= {hardwareCESTrapInfo 7}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2505)

    Philippou Jim

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2505.1.1.7.0 fanTwoStatus 0 0 None

    Brothers (47)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2505.1.1.1 hardDisk1Status 1 1 Hard Disk Number 1 Status.
    Possible Values:
    Warning: Hard Disk 1 : Device /ide1/ not available
    Warning: Hard Disk 1 : Utilization …
    1.3.6.1.4.1.2505.1.1.2 hardDisk0Status 1 1 Hard Disk Number 0 Status.
    Possible Values:
    Warning: Hard Disk 0 : Device /ide0/ not available
    Warning: Hard Disk 0 : Utilization …
    1.3.6.1.4.1.2505.1.1.3 memoryUsage 1 1 Memory Usage Status.
    Possible Values:
    Warning: Memory Usage : Utilization exceeds 75%
    Alert: Memory Usage : Utilization exceeds 87…
    1.3.6.1.4.1.2505.1.1.4 lanCardStatus 1 1 Status of any LAN cards on the system.
    Possible Values:
    Please note that X corresponds to the Xth slot in the system.
    Please note …
    1.3.6.1.4.1.2505.1.1.5 cpuTwoStatus 1 1 Status of second CPU.
    Possible Values:
    Alert: CPU 2: Program load failed;
    Alert: CPU 2: Bootup did not complete;
    Alert: CPU 2: Comm…
    1.3.6.1.4.1.2505.1.1.6 fanOneStatus 1 1 Status of the first CPU fan.
    Possible Values:
    Alert: CPU One Fan: Fan not functioning;

    This indicates that the fan on the primary …
    1.3.6.1.4.1.2505.1.1.8 chassisFanStatus 1 1 Status of the chassis fan.
    Possible Values:
    Alert: Chassis Fan: Fan not functioning;
    Alert: Chassis Fan 2: Fan not functioning;

    Thi…
    1.3.6.1.4.1.2505.1.1.9 fiveVoltsPositive 1 1 Status of +5 Volt power.
    Possible Values:
    Alert: Voltage 5 V Plus: Voltage out of range;

    The supplied voltage to the system is not…
    1.3.6.1.4.1.2505.1.1.10 fiveVoltsMinus 1 1 Status of -5 Volt power.
    Possible Values:
    Alert: Voltage 5 V Minus: Voltage out of range;

    The supplied voltage to the system is no…
    1.3.6.1.4.1.2505.1.1.11 threeVoltsPositive 1 1 Status of +3 Volt power.
    Possible Values:
    Alert: Voltage 3.3 V Plus: Voltage out of range;

    The supplied voltage to the system is n…
    1.3.6.1.4.1.2505.1.1.12 twoDotFiveVA 1 1 Status of 2.5VA power.
    Possible Values:
    Alert: Voltage 2.5 VA: Voltage out of range;

    This is the voltage supplied to the primary p…
    1.3.6.1.4.1.2505.1.1.13 twoDotFiveVB 1 1 Status of 2.5VB power.
    Possible Values:
    Alert: Voltage 2.5 VB: Voltage out of range;

    This is the voltage supplied to the seconary …
    1.3.6.1.4.1.2505.1.1.14 twelveVoltsPositive 1 1 Status of +12 Volt power.
    Possible Values:
    Alert: Voltage 12 V Plus: Voltage out of range;

    The supplied voltage to the system is n…
    1.3.6.1.4.1.2505.1.1.15 twelveVoltsMinus 1 1 Status of -12 Volt power.
    Possible Values:
    Alert: Voltage 12 V Minus: Voltage out of range;

    The supplied voltage to the system is …
    1.3.6.1.4.1.2505.1.1.16 normalTemperature 1 1 Status of normal temperature reading.
    Possible Values:
    Alert: Normal Temperature: Normal temperature out of range;

    This indicates …
    1.3.6.1.4.1.2505.1.1.17 criticalTemperature 1 1 Status of critical temperature reading.
    Possible Values:
    Alert: Critical Temperature: Critial temperature out of range;

    This indic…
    1.3.6.1.4.1.2505.1.1.18 chassisIntrusion 1 1 The chassis intrusion sensor indicates that the unit has been opened.

    Possible Values:
    Alert: Intrusion: Box has been opened;

    The …
    1.3.6.1.4.1.2505.1.1.19 dualPowerSupply 1 1 Status of the redundant power supplies.
    Possible Values:
    Alert: Dual Power Supply: Redundant supply faulted

    This indicates that, o…
    1.3.6.1.4.1.2505.1.1.20 t1WANStatus 1 1 Status of T1 WAN card(s).
    Possible Values:
    For Wanic support:
    Alert: Invalid Device X
    Warning: Device WanicX disabled
    Alert: Device …
    1.3.6.1.4.1.2505.1.1.21 t3WANStatus 1 1 Status of T3 WAN card
    Possible Values:
    Alert: Invalid Index X
    Warning: Device HSSIX disabled
    Alert: Device HSSIX down
    Warning: Devic…
    1.3.6.1.4.1.2505.1.1.22 hwAccelStatus 1 1 Status of hardware accelerator card.
    1.3.6.1.4.1.2505.1.1.24 v90WANStatus 1 1 Status of V.90 Interface card
    Possible Values:
    Please note that X corresponds to the unit number of the card.
    Alert: V.90 Invalid …
    1.3.6.1.4.1.2505.1.1.25 briWANStatus 1 1 Status of ISDN BRI Interface card
    Possible Values:
    Please note that X corresponds to the unit number of the card.
    Alert: BRI Inval…
    1.3.6.1.4.1.2505.1.1.26 serUartStatus 1 1 Status of Serial (COM) port/interface
    Possible Values:
    Please note that X corresponds to the unit number of the serial interface
    A…
    1.3.6.1.4.1.2505.1.1.27 adslWANStatus 1 1 Status of ADI ADSL card
    Possible Values:
    Please note that X corresponds to the unit number of the serial interface
    Alert: Invalid …
    1.3.6.1.4.1.2505.1.1.1001 hardDisk1StatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1002 hardDisk0StatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1003 memoryUsageTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1004 lanCardStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1005 cpuTwoStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1006 fanOneStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1007 fanTwoStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1008 chassisFanStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.1009 fiveVoltsPosStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10010 fiveVoltsMinusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10011 threeVoltsPositiveTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10012 twoDotFiveVATrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10013 twoDotFiveVBTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10014 twelveVoltsPositveTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10015 twelveVoltsMinsTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10016 normalTemperatureTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10017 criticalTemperatureTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10018 chassisIntrusionTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10019 dualPowerSupplyTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10020 t1WANStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10021 t3WANStatusTrap 0 0 None
    1.3.6.1.4.1.2505.1.1.10022 hwAccelTrap 0 0 None