The high humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled(2) and
the threshold has been violated.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The high humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled(2) and
the threshold has been violated.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
emConfigProbeHighHumidEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated." ::= { emConfigProbesEntry 10 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
emConfigProbeHighHumidEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated." ::= { emConfigProbesEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.10.1.2.2.1.1 | emConfigProbeNumber | 0 | 0 | The index into an Environmental Monitor probe entry. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.2 | emConfigProbeName | 0 | 0 | A descriptive name of the probe set by the user, possibly denoting its location or purpose. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.3 | emConfigProbeHighTempThreshold | 0 | 0 | emConfigProbeHightempThreshold |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.4 | emConfigProbeLowTempThreshold | 0 | 0 | The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID … |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.5 | emConfigProbeTempUnits | 0 | 0 | The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.6 | emConfigProbeHighHumidThreshold | 0 | 0 | The high humidity alarm threshold for the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.7 | emConfigProbeLowHumidThreshold | 0 | 0 | The low humidity alarm threshold for the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.8 | emConfigProbeHighTempEnable | 0 | 0 | emConfigProbeHightempEnable |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.9 | emConfigProbeLowTempEnable | 0 | 0 | The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.11 | emConfigProbeLowHumidEnable | 0 | 0 | The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm wi… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.12 | emConfigProbeMaxTempThreshold | 0 | 0 | The maximum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' … |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.13 | emConfigProbeMinTempThreshold | 0 | 0 | The minimum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' … |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.14 | emConfigProbeMaxHumidThreshold | 0 | 0 | The maximun humidity alarm threshold for the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.15 | emConfigProbeMinHumidThreshold | 0 | 0 | The minimum humidity alarm threshold for the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.16 | emConfigProbeMaxTempEnable | 0 | 0 | The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The a… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.17 | emConfigProbeMinTempEnable | 0 | 0 | The minimum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The a… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.18 | emConfigProbeMaxHumidEnable | 0 | 0 | The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alar… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.19 | emConfigProbeMinHumidEnable | 0 | 0 | The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alar… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.20 | emConfigProbeTempHysteresis | 0 | 0 | The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration … |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.21 | emConfigProbeHumidHysteresis | 0 | 0 | The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configurat… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.22 | emConfigProbeLocation | 0 | 0 | A string describing the location of the probe. |