The maximum temperature alarm threshold for the probe.
Units are displayed in the scale selected in
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The maximum temperature alarm threshold for the probe.
Units are displayed in the scale selected in
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
emConfigProbeMaxTempThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." ::= { emConfigProbesEntry 12 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
emConfigProbeMaxTempThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)." ::= { emConfigProbesEntry 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.10.1.2.2.1.1 | emConfigProbeNumber | 0 | 0 | The index into an Environmental Monitor probe entry. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.2 | emConfigProbeName | 0 | 0 | A descriptive name of the probe set by the user, possibly denoting its location or purpose. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.3 | emConfigProbeHighTempThreshold | 0 | 0 | emConfigProbeHightempThreshold |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.4 | emConfigProbeLowTempThreshold | 0 | 0 | The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID … |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.5 | emConfigProbeTempUnits | 0 | 0 | The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.6 | emConfigProbeHighHumidThreshold | 0 | 0 | The high humidity alarm threshold for the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.7 | emConfigProbeLowHumidThreshold | 0 | 0 | The low humidity alarm threshold for the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.8 | emConfigProbeHighTempEnable | 0 | 0 | emConfigProbeHightempEnable |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.9 | emConfigProbeLowTempEnable | 0 | 0 | The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.10 | emConfigProbeHighHumidEnable | 0 | 0 | The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm w… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.11 | emConfigProbeLowHumidEnable | 0 | 0 | The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm wi… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.13 | emConfigProbeMinTempThreshold | 0 | 0 | The minimum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' … |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.14 | emConfigProbeMaxHumidThreshold | 0 | 0 | The maximun humidity alarm threshold for the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.15 | emConfigProbeMinHumidThreshold | 0 | 0 | The minimum humidity alarm threshold for the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.16 | emConfigProbeMaxTempEnable | 0 | 0 | The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The a… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.17 | emConfigProbeMinTempEnable | 0 | 0 | The minimum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The a… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.18 | emConfigProbeMaxHumidEnable | 0 | 0 | The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alar… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.19 | emConfigProbeMinHumidEnable | 0 | 0 | The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alar… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.20 | emConfigProbeTempHysteresis | 0 | 0 | The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration … |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.21 | emConfigProbeHumidHysteresis | 0 | 0 | The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configurat… |
1.3.6.1.4.1.318.1.1.10.1.2.2.1.22 | emConfigProbeLocation | 0 | 0 | A string describing the location of the probe. |