The current temperature reading from the probe displayed
in the units shown in the 'emStatusProbeTempUnits' OID
(Celsius or Fahrenheit).
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The current temperature reading from the probe displayed
in the units shown in the 'emStatusProbeTempUnits' OID
(Celsius or Fahrenheit).
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
emStatusProbeCurrentTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current temperature reading from the probe displayed in the units shown in the 'emStatusProbeTempUnits' OID (Celsius or Fahrenheit)." ::= { emStatusProbesEntry 4 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
emStatusProbeCurrentTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current temperature reading from the probe displayed in the units shown in the 'emStatusProbeTempUnits' OID (Celsius or Fahrenheit)." ::= { emStatusProbesEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.10.1.3.3.1.1 | emStatusProbeNumber | 0 | 0 | The index of the probe. |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.2 | emStatusProbeName | 0 | 0 | A descriptive name for the probe set by the user, possibly denoting its location or purpose. |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.3 | emStatusProbeStatus | 0 | 0 | The connected status of the probe, either disconnected(1) or connected(2). |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.5 | emStatusProbeTempUnits | 0 | 0 | The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based… |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.6 | emStatusProbeCurrentHumid | 0 | 0 | The current humidity reading from the probe in percent relative humidity. |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.7 | emStatusProbeHighTempViolation | 0 | 0 | emStatusProbeHightempViolation |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.8 | emStatusProbeLowTempViolation | 0 | 0 | The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current t… |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.9 | emStatusProbeHighHumidViolation | 0 | 0 | The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidi… |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.10 | emStatusProbeLowHumidViolation | 0 | 0 | The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity… |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.11 | emStatusProbeMaxTempViolation | 0 | 0 | The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current te… |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.12 | emStatusProbeMinTempViolation | 0 | 0 | The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the curren… |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.13 | emStatusProbeMaxHumidViolation | 0 | 0 | The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humi… |
1.3.6.1.4.1.318.1.1.10.1.3.3.1.14 | emStatusProbeMinHumidViolation | 0 | 0 | The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humi… |