Reference record for OID 1.3.6.1.4.1.318.1.1.12.1.13



parent
1.3.6.1.4.1.318.1.1.12.1 (rPDUIdent)
node code
13
node name
rPDUIdentDeviceOutletLayout
dot oid
1.3.6.1.4.1.318.1.1.12.1.13
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceOutletLayout(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceOutletLayout(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceOutletLayout(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceOutletLayout(13)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceOutletLayout(13)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceOutletLayout(13)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceOutletLayout
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceOutletLayout
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceOutletLayout
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceOutletLayout
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceOutletLayout
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceOutletLayout
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/12/1/13

    Description by mibdepot

    Getting this OID will return outlet layout for the device.

    seqPhaseToNeutral(1) indicates outlet layout as follows:
    1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...

    seqPhaseToPhase(2) indicates outlet layout as follows:
    1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...

    seqPhToNeu21PhToPh(3) indicates outlet layout as follows:
    1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...

    seqPhToPhGrouped(4) indicates outlet layout as follows:
    For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1.
    For AP7xxx SKU's Group 1:3-1. Group 2:2-3, Group 3:1-2.

    seqPhToNGrouped(5) indicates outlet layout as follows:
    This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N.

    seqPToN1516PToPGrouped(6) indicates outlet layout as follows:
    This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2,
    Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1.

    seqPhToPh2xGrouped(7) indicates outlet layout as follows:
    This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3,
    Group 4:2-3, Group 5:3-1, Group 6:3-1.

    seqPhToN2xGrouped(8) indicates outlet layout as follows:
    This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N,
    Group 4:2-N, Group 5:3-N, Group 6:3-N.

    seqNotApplicable(9):
    Outlet layout does not affect any of the user interfaces.
    These SKUs may report seqNotApplicable(9) if there is
    not an exact outlet layout match available.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Getting this OID will return outlet layout for the device.

    seqPhaseToNeutral(1) indicates outlet layout as follows:
    1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...

    seqPhaseToPhase(2) indicates outlet layout as follows:
    1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...

    seqPhToNeu21PhToPh(3) indicates outlet layout as follows:
    1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...

    seqPhToPhGrouped(4) indicates outlet layout as follows:
    This unit has 3 outlet groups. Group 1:1-2, Group 2:2-3, Group 3:3-1.

    seqPhToNGrouped(5) indicates outlet layout as follows:
    This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N.

    seqPToN1516PToPGrouped(6) indicates outlet layout as follows:
    This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2,
    Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1.

    seqPhToPh2xGrouped(7) indicates outlet layout as follows:
    This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3,
    Group 4:2-3, Group 5:3-1, Group 6:3-1.

    seqPhToN2xGrouped(8) indicates outlet layout as follows:
    This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N,
    Group 4:2-N, Group 5:3-N, Group 6:3-N.

    seqNotApplicable(9):
    Outlet layout does not affect any of the user interfaces.
    These SKUs may report seqNotApplicable(9) if there is
    not an exact outlet layout match available.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    rPDUIdentDeviceOutletLayout OBJECT-TYPE SYNTAX INTEGER { seqPhaseToNeutral (1), seqPhaseToPhase (2), seqPhToNeu21PhToPh (3), seqPhToPhGrouped (4), seqPhToNGrouped (5), seqPToN1516PToPGrouped (6), seqPhToPh2xGrouped (7), seqPhToN2xGrouped (8), seqNotApplicable (9) } ACCESS read-only STATUS mandatory DESCRIPTION "Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1. For AP7xxx SKU's Group 1:3-1. Group 2:2-3, Group 3:1-2. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9): Outlet layout does not affect any of the user interfaces. These SKUs may report seqNotApplicable(9) if there is not an exact outlet layout match available." ::= { rPDUIdent 13 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    rPDUIdentDeviceOutletLayout OBJECT-TYPE SYNTAX INTEGER { seqPhaseToNeutral (1), seqPhaseToPhase (2), seqPhToNeu21PhToPh (3), seqPhToPhGrouped (4), seqPhToNGrouped (5), seqPToN1516PToPGrouped (6), seqPhToPh2xGrouped (7), seqPhToN2xGrouped (8), seqNotApplicable (9) } ACCESS read-only STATUS mandatory DESCRIPTION "Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-2, Group 2:2-3, Group 3:3-1. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9): Outlet layout does not affect any of the user interfaces. These SKUs may report seqNotApplicable(9) if there is not an exact outlet layout match available." ::= { rPDUIdent 13 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.12.1.13.0 rPDUIdentDeviceOutletLayout 0 0 None

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.12.1.1 rPDUIdentName 1 1 The name of the Rack PDU.
    The maximum string size is device dependent.
    1.3.6.1.4.1.318.1.1.12.1.2 rPDUIdentHardwareRev 1 1 The hardware revision of the Rack PDU.
    This value is set at the factory.
    1.3.6.1.4.1.318.1.1.12.1.3 rPDUIdentFirmwareRev 1 1 An 8-byte ID string identifying the Rack PDU firmware revision.
    This value is set at the factory.
    1.3.6.1.4.1.318.1.1.12.1.4 rPDUIdentDateOfManufacture 1 1 The date when the Rack PDU was manufactured in mm/dd/yyyy format.
    This value is set at the factory. The year 2000 will be
    represe…
    1.3.6.1.4.1.318.1.1.12.1.5 rPDUIdentModelNumber 1 1 A 10-character string identifying the model number of
    the Rack PDU. This value is set at the factory.
    1.3.6.1.4.1.318.1.1.12.1.6 rPDUIdentSerialNumber 1 1 A 12-character string identifying the serial number of
    the Rack PDU. This value is set at the factory.
    1.3.6.1.4.1.318.1.1.12.1.7 rPDUIdentDeviceRating 1 1 Getting this OID will return the electrical rating of the device in Amps.
    1.3.6.1.4.1.318.1.1.12.1.8 rPDUIdentDeviceNumOutlets 1 1 Getting this OID will return the number of outlets contained in the device.
    1.3.6.1.4.1.318.1.1.12.1.9 rPDUIdentDeviceNumPhases 1 1 Getting this OID will return the number of phases supported by the device.
    1.3.6.1.4.1.318.1.1.12.1.10 rPDUIdentDeviceNumBreakers 1 1 Getting this OID will return the number of circuit breakers supported by the device.
    This is the same as the number of banks of …
    1.3.6.1.4.1.318.1.1.12.1.11 rPDUIdentDeviceBreakerRating 1 1 Getting this OID will return rating of the circuit breakers
    on the device in Amps if it has any.
    1.3.6.1.4.1.318.1.1.12.1.12 rPDUIdentDeviceOrientation 1 1 Getting this OID will return the intended physical orientation of the device.

    OrientHorizonatal(1) indicates Horizontal.
    OrientV…
    1.3.6.1.4.1.318.1.1.12.1.14 rPDUIdentDeviceDisplayOrientation 1 1 Getting this OID will return the intended physical orientation of the Seven-Segment Display.

    Normal(1) indicates Normal.
    Reverse…
    1.3.6.1.4.1.318.1.1.12.1.15 rPDUIdentDeviceLinetoLineVoltage 1 1 Getting/Setting this OID will return/set the Line to Line Voltage.
    This OID defaults to the nominal input line voltage in volts …
    1.3.6.1.4.1.318.1.1.12.1.16 rPDUIdentDevicePowerWatts 1 1 Getting this OID will return the Power in Watts.
    1.3.6.1.4.1.318.1.1.12.1.17 rPDUIdentDevicePowerFactor 1 1 Getting/setting this OID will return/set the
    Power Factor in thousanths (1000 is power factor of 1).
    For AP8XXX SKUs, this OID is…
    1.3.6.1.4.1.318.1.1.12.1.18 rPDUIdentDevicePowerVA 1 1 Getting this OID will return the Power in VA.
    1.3.6.1.4.1.318.1.1.12.1.19 rPDUIdentDeviceLinetoNeutralVoltage 0 0 Getting/Setting this OID will return/set the Line to Neutral Voltage.
    This OID defaults to the nominal line to neutral voltage i…