Reference record for OID 1.3.6.1.4.1.318.1.1.12.1.15



parent
1.3.6.1.4.1.318.1.1.12.1 (rPDUIdent)
node code
15
node name
rPDUIdentDeviceLinetoLineVoltage
dot oid
1.3.6.1.4.1.318.1.1.12.1.15
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceLinetoLineVoltage(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceLinetoLineVoltage(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceLinetoLineVoltage(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceLinetoLineVoltage(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceLinetoLineVoltage(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU(12) rPDUIdent(1) rPDUIdentDeviceLinetoLineVoltage(15)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceLinetoLineVoltage
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceLinetoLineVoltage
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceLinetoLineVoltage
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceLinetoLineVoltage
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceLinetoLineVoltage
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/rPDU/rPDUIdent/rPDUIdentDeviceLinetoLineVoltage
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/12/1/15

    Description by mibdepot

    Getting/Setting this OID will return/set the Line to Line Voltage.
    This OID defaults to the nominal input line voltage in volts AC.
    This setting is used to calculate total power and must be configured for best accuracy.
    This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs.

    The valid range is between 0V to 440V

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Getting/Setting this OID will return/set the Line to Line Voltage.
    This OID defaults to the nominal input line voltage in volts AC.
    This setting is used to calculate total power and must be configured for best accuracy.
    This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs.

    The valid range is between 0V to 440V

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    rPDUIdentDeviceLinetoLineVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Getting/Setting this OID will return/set the Line to Line Voltage. This OID defaults to the nominal input line voltage in volts AC. This setting is used to calculate total power and must be configured for best accuracy. This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs. The valid range is between 0V to 440V" ::= { rPDUIdent 15 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    rPDUIdentDeviceLinetoLineVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Getting/Setting this OID will return/set the Line to Line Voltage. This OID defaults to the nominal input line voltage in volts AC. This setting is used to calculate total power and must be configured for best accuracy. This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs. The valid range is between 0V to 440V" ::= { rPDUIdent 15 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.12.1.15.0 rPDUIdentDeviceLinetoLineVoltage 0 0 None

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.12.1.1 rPDUIdentName 1 1 The name of the Rack PDU.
    The maximum string size is device dependent.
    1.3.6.1.4.1.318.1.1.12.1.2 rPDUIdentHardwareRev 1 1 The hardware revision of the Rack PDU.
    This value is set at the factory.
    1.3.6.1.4.1.318.1.1.12.1.3 rPDUIdentFirmwareRev 1 1 An 8-byte ID string identifying the Rack PDU firmware revision.
    This value is set at the factory.
    1.3.6.1.4.1.318.1.1.12.1.4 rPDUIdentDateOfManufacture 1 1 The date when the Rack PDU was manufactured in mm/dd/yyyy format.
    This value is set at the factory. The year 2000 will be
    represe…
    1.3.6.1.4.1.318.1.1.12.1.5 rPDUIdentModelNumber 1 1 A 10-character string identifying the model number of
    the Rack PDU. This value is set at the factory.
    1.3.6.1.4.1.318.1.1.12.1.6 rPDUIdentSerialNumber 1 1 A 12-character string identifying the serial number of
    the Rack PDU. This value is set at the factory.
    1.3.6.1.4.1.318.1.1.12.1.7 rPDUIdentDeviceRating 1 1 Getting this OID will return the electrical rating of the device in Amps.
    1.3.6.1.4.1.318.1.1.12.1.8 rPDUIdentDeviceNumOutlets 1 1 Getting this OID will return the number of outlets contained in the device.
    1.3.6.1.4.1.318.1.1.12.1.9 rPDUIdentDeviceNumPhases 1 1 Getting this OID will return the number of phases supported by the device.
    1.3.6.1.4.1.318.1.1.12.1.10 rPDUIdentDeviceNumBreakers 1 1 Getting this OID will return the number of circuit breakers supported by the device.
    This is the same as the number of banks of …
    1.3.6.1.4.1.318.1.1.12.1.11 rPDUIdentDeviceBreakerRating 1 1 Getting this OID will return rating of the circuit breakers
    on the device in Amps if it has any.
    1.3.6.1.4.1.318.1.1.12.1.12 rPDUIdentDeviceOrientation 1 1 Getting this OID will return the intended physical orientation of the device.

    OrientHorizonatal(1) indicates Horizontal.
    OrientV…
    1.3.6.1.4.1.318.1.1.12.1.13 rPDUIdentDeviceOutletLayout 1 1 Getting this OID will return outlet layout for the device.

    seqPhaseToNeutral(1) indicates outlet layout as follows:
    1:1-N,2:2-N,3…
    1.3.6.1.4.1.318.1.1.12.1.14 rPDUIdentDeviceDisplayOrientation 1 1 Getting this OID will return the intended physical orientation of the Seven-Segment Display.

    Normal(1) indicates Normal.
    Reverse…
    1.3.6.1.4.1.318.1.1.12.1.16 rPDUIdentDevicePowerWatts 1 1 Getting this OID will return the Power in Watts.
    1.3.6.1.4.1.318.1.1.12.1.17 rPDUIdentDevicePowerFactor 1 1 Getting/setting this OID will return/set the
    Power Factor in thousanths (1000 is power factor of 1).
    For AP8XXX SKUs, this OID is…
    1.3.6.1.4.1.318.1.1.12.1.18 rPDUIdentDevicePowerVA 1 1 Getting this OID will return the Power in VA.
    1.3.6.1.4.1.318.1.1.12.1.19 rPDUIdentDeviceLinetoNeutralVoltage 0 0 Getting/Setting this OID will return/set the Line to Neutral Voltage.
    This OID defaults to the nominal line to neutral voltage i…