Vendor: Raymond and Lae Engineering, Inc.
Module: RLE-FALCON-MIB
[Automatically extracted from oidview.com]
FalconInput8 OBJECT IDENTIFIER ::= { FalconInputs 8 }
falconInput8 OBJECT IDENTIFIER ::= { falconInputs 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3184.1.1.1.3.8.1 | FalconInput8State | 1 | 1 | The state of use of Input Number 8. When a sensor is connected to Input 8 set State to installed(2) to indicate that the value of… |
1.3.6.1.4.1.3184.1.1.1.3.8.2 | FalconInput8Reading | 1 | 1 | The reading for sensor 8. If the input is digital, the reading will be 1 (active) or 0 (inactive) |
1.3.6.1.4.1.3184.1.1.1.3.8.3 | FalconInput8Gain | 1 | 1 | A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 8 to… |
1.3.6.1.4.1.3184.1.1.1.3.8.4 | FalconInput8Offset | 1 | 1 | A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 8 to … |
1.3.6.1.4.1.3184.1.1.1.3.8.5 | FalconInput8Label | 1 | 1 | A user-defined text string associated with Input Number 8. The text string is stored in non-volatile memory. |
1.3.6.1.4.1.3184.1.1.1.3.8.6 | FalconInput8UOM | 1 | 1 | A user-defined text string associated with Input Number 8. The text string is stored in non-volatile memory. |
1.3.6.1.4.1.3184.1.1.1.3.8.7 | FalconInput8HighLimit2 | 1 | 1 | When input 8 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 8. The HighLimit v… |
1.3.6.1.4.1.3184.1.1.1.3.8.8 | FalconInput8HighLimit | 1 | 1 | When input 8 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 8. The HighLimit v… |
1.3.6.1.4.1.3184.1.1.1.3.8.9 | FalconInput8LowLimit, FalconInput8RlyControl | 1 | 1 | When input 8 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 8. The LowLimit… |
1.3.6.1.4.1.3184.1.1.1.3.8.10 | FalconInput8LowLimit2, FalconInput8Delay | 1 | 1 | The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This varia… |
1.3.6.1.4.1.3184.1.1.1.3.8.11 | FalconInput8Hysteresis | 1 | 1 | The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will cle… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3184.1.1.1.3.1 | FalconInput1 | 13 | 26 | None |
1.3.6.1.4.1.3184.1.1.1.3.2 | FalconInput2 | 13 | 26 | None |
1.3.6.1.4.1.3184.1.1.1.3.3 | FalconInput3 | 13 | 26 | None |
1.3.6.1.4.1.3184.1.1.1.3.4 | FalconInput4 | 13 | 26 | None |
1.3.6.1.4.1.3184.1.1.1.3.5 | FalconInput5 | 13 | 26 | None |
1.3.6.1.4.1.3184.1.1.1.3.6 | FalconInput6 | 13 | 26 | None |
1.3.6.1.4.1.3184.1.1.1.3.7 | FalconInput7 | 13 | 26 | None |
1.3.6.1.4.1.3184.1.1.1.3.25 | FalconInput9 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.26 | FalconInput10 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.27 | FalconInput11 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.28 | FalconInput12 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.29 | FalconInput13 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.30 | FalconInput14 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.31 | FalconInput15 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.32 | FalconInput16 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.33 | FalconInput17 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.34 | FalconInput18 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.35 | FalconInput19 | 5 | 10 | None |
1.3.6.1.4.1.3184.1.1.1.3.36 | FalconInput20 | 5 | 10 | None |