This object is used to select how the jitter attenuation
circuit on the CSU is to be used. It can be used to
attenuate jitter on the receiver, or the transmitter.
Parsed from file RDS1.MIB.txt
Company: cai
Module: RDS1-MIB
Vendor: 3Com
Module: RDS1-MIB (RDS1.MIB)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
usrds1CfgJitterAttnution OBJECT-TYPE SYNTAX INTEGER{ attenJitterOnRcvr(1), attenJitterOnTxmtr(2) } ACCESS read-write STATUS optional DESCRIPTION "This object is used to select how the jitter attenuation circuit on the CSU is to be used. It can be used to attenuate jitter on the receiver, or the transmitter." ::= { usrds1ConfigEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.429.1.27.1.1.1 | usrds1CfgIndex | 0 | 0 | The index value which uniquely identifies the CSU to which this entry is applicable. This index corresponds to dsx1LineIndex def… |
1.3.6.1.4.1.429.1.27.1.1.2 | usrds1CfgRspToRemoteLpbk | 0 | 0 | This object configures the specified CSU to either ignore or respond to remotely initiated loopback requests. |
1.3.6.1.4.1.429.1.27.1.1.4 | usrds1CfgXmitLineBuildOut | 0 | 0 | This object is used to configure the amount of attenuation that is to be applied to the transmit signal in order to control cross… |
1.3.6.1.4.1.429.1.27.1.1.5 | usrds1CfgDialInAdr | 0 | 0 | This object identifies whether or not type of MF/DTMF will be transferred as part of the call setup for the specified T1 line. |
1.3.6.1.4.1.429.1.27.1.1.6 | usrds1CfgDialInOutTrunkSt | 0 | 0 | This will set the Dial-in/Dial-out trunk start signal type. Default = wink(1). |
1.3.6.1.4.1.429.1.27.1.1.7 | usrds1CfgDialInAdrAckWink | 0 | 0 | Allows to enable/disable an acknowledgment wink after the dial-in address information has been received. |
1.3.6.1.4.1.429.1.27.1.1.8 | usrds1CfgDialOutAdrDly | 0 | 0 | Allows an adjustable delay on sending out address information from the T1 NAC to the TELCO. |
1.3.6.1.4.1.429.1.27.1.1.9 | usrds1CfgDialIOTrunkType | 0 | 0 | This will set the Dial-In/Dial-out trunk type. Default = eAndMTypeII(1). |
1.3.6.1.4.1.429.1.27.1.1.10 | usrds1CfgPriSwitchType | 0 | 0 | usrds1CfgPriSwitchtype |
1.3.6.1.4.1.429.1.27.1.1.11 | usrds1CfgIdleByte | 0 | 0 | This sets the idle byte pattern for the T1-PRI ISDN NAC. The setting takes effect at NAC boot time. Default = 0xFE. |
1.3.6.1.4.1.429.1.27.1.1.12 | usrds1CfgAnlgBlockErrCode | 0 | 0 | This is the error code that will be returned to an ISDN switch when analog connections are being blocked. Default = 58. |
1.3.6.1.4.1.429.1.27.1.1.13 | usrds1CfgDgtlBlockErrCode | 0 | 0 | This is the error code that will be returned to an ISDN switch when digital connections are being blocked. Default = 58. |
1.3.6.1.4.1.429.1.27.1.1.14 | usrds1CfgNoIgwAvailErCode | 0 | 0 | This is the error code that will be returned to an ISDN switch when there are no modems available to accept the requested connect… |
1.3.6.1.4.1.429.1.27.1.1.15 | usrds1CfgChanBlockErrCode | 0 | 0 | This is the error code that will be returned to an ISDN switch when connections to a specific B channel are being blocked. Default… |
1.3.6.1.4.1.429.1.27.1.1.16 | usrds1CfgBlockCallType | 0 | 0 | This object determines if a PRI span line will block calls of a specific type. This object does not apply to a NAC operating in … |
1.3.6.1.4.1.429.1.27.1.1.17 | usrds1CfgShrtHaulDist, usrds1ShrtHaulDist | 0 | 0 | Various distance ranges supported by Short Haul NIC Default=len0thru133Ft. |
1.3.6.1.4.1.429.1.27.1.1.18 | usrds1CfgNicCfgType, usrdsx1NicCfgType | 0 | 0 | Type of T1/E1 interface configured - Short haul of long haul. |
1.3.6.1.4.1.429.1.27.1.1.19 | usrds1CfgToneType, usrds1ToneType | 0 | 0 | DS1 Tone type (MF/DTMF) - CHT1 only. |
1.3.6.1.4.1.429.1.27.1.1.20 | usrds1CfgNumDtmfTones, usrds1NumDtmfTones | 0 | 0 | usrds1CfgNumDtmftones |
1.3.6.1.4.1.429.1.27.1.1.21 | usrds1CfgDialOutSlctDirct, usrchT1E1DialOutSlctDirct | 0 | 0 | This object defines whether DS0 are chosen hunting up or down from the currently defined staring DS0. Default=down. |
1.3.6.1.4.1.429.1.27.1.1.22 | usrds1CfgDialOutNextDS0, usrchT1E1DialOutNextDS0 | 0 | 0 | This object defines the starting DS0s to do dial-out hunting from. |
1.3.6.1.4.1.429.1.27.1.1.23 | usrds1CfgRcvGain | 0 | 0 | This object is used to configure the amount of Receiver Gain that is applied to the received signal at the CSU. T1 Long Haul: 26 … |
1.3.6.1.4.1.429.1.27.1.1.24 | usrds1CfgCht1Profile | 0 | 0 | The following object is used to configure profile for channelized T1. Following are the profile setting for each available option… |
1.3.6.1.4.1.429.1.27.1.1.25 | usrds1CfgCallProceedngRsp | 0 | 0 | This Object determines to send CALL_PROCEEDING and CONNECT response, when a SETUP message received from TELCO. Default = ON. |
1.3.6.1.4.1.429.1.27.1.1.26 | usrds1CfgAlertingRsp | 0 | 0 | This Object determines to send ALERTING response, when a SETUP message is received from TELCO. Default = OFF. |
1.3.6.1.4.1.429.1.27.1.1.27 | usrds1CfgOverLapRxMode | 0 | 0 | This Object allows dialed digits to arrive in separate messages. Default=disabled(2). |
1.3.6.1.4.1.429.1.27.1.1.28 | usrds1CfgNFASInterfaceId | 0 | 0 | This object indicates external ( assigned by Telco ) interface id. It is one of the entries in the NFAS group table. |
1.3.6.1.4.1.429.1.27.1.1.29 | usrds1CfgSigGroupNumber | 0 | 0 | Indicates NFAS ( or SS7 ) logical group number to be monitored ( configured). This variable serves as an index for entering NFAS… |
1.3.6.1.4.1.429.1.27.1.1.30 | usrds1CfgNFASSpanType | 0 | 0 | Span type with regard to the D-Channel: Primary, Back-up, None or FAS (the latter in case if NFAS is not configured). It is one o… |
1.3.6.1.4.1.429.1.27.1.1.31 | usrds1CfgSigGroupType | 0 | 0 | This variable indicates one of the three possible application types: FAS, NFAS, or FAS. FAS stands for facility associated signal… |
1.3.6.1.4.1.429.1.27.1.1.32 | usrds1CfgOutBearerCap | 0 | 0 | Controls the bearer capability for outgoing analog calls. Default=audio3K(1). |
1.3.6.1.4.1.429.1.27.1.1.33 | usrds1CfgSs7Mode | 0 | 0 | This object is used to select if the span line is to be controlled by a SS7 device. A value of None indicates that the span line … |
1.3.6.1.4.1.429.1.27.1.1.34 | usrds1CfgInfoMsgTimeOut | 0 | 0 | This object sets the time out delay in seconds between INFO message. This parameter is effective if overlap RX mode is enabled. D… |
1.3.6.1.4.1.429.1.27.1.1.35 | usrds1CfgInbDNISLength | 0 | 0 | This objects sets the total number of digits expected in the inbound phone number. In the E1-PRI this is only effective when over… |
1.3.6.1.4.1.429.1.27.1.1.36 | usrds1CfgAnsDly | 0 | 0 | This object defines E&MII answer supervision delay time. Default = 11, in 10 ms interval. e.g. 1 = 10 ms |
1.3.6.1.4.1.429.1.27.1.1.37 | usrds1CfgDiscDeb | 0 | 0 | This object defines E&MII E-lead disc debounce time. Default = 30 in 10 ms interval. e.g 30 = 300 ms |
1.3.6.1.4.1.429.1.27.1.1.38 | usrds1CfgSanity | 0 | 0 | This object defines E&MII Telco disc sanity time. Default = 10 sec |
1.3.6.1.4.1.429.1.27.1.1.39 | usrds1CfgWink | 0 | 0 | This object defines E&MII Wink Duration. Default = 20, in 10 ms interval. e.g. 20 = 200 ms |
1.3.6.1.4.1.429.1.27.1.1.40 | usrds1CfgV42Wan | 0 | 0 | This object defines E&MII V42 to WAN disc delay time. Default = 0. 0-254 in 100 ms intervals, a configuration of 255 is 125 sec. |
1.3.6.1.4.1.429.1.27.1.1.41 | usrds1CfgTeldis | 0 | 0 | This object defines E&MII Telco init disc delay time. Default = 0 in 100 ms interval. e.g 1 = 100 ms |
1.3.6.1.4.1.429.1.27.1.1.42 | usrds1CfgSeize | 0 | 0 | This object defines E&MII Seizure to Wink delay time. Default = 22, in 10 ms interval. e.g. 22 = 220 ms |
1.3.6.1.4.1.429.1.27.1.1.43 | usrds1CfgDSPFailureAction | 0 | 0 | This object tells a DSP what action to take when it detects that neither of its pumps is able to complete a call at the physical … |
1.3.6.1.4.1.429.1.27.1.1.44 | usrds1CfgR2AnsHoldTimer | 0 | 0 | This object controls the minimum duration for which the E1 R2 Answer line signal will be transmitted before any other signal is t… |
1.3.6.1.4.1.429.1.27.1.1.45 | usrds1CfgHsOnProgMsg | 0 | 0 | This object allows outgoing analog calls over PRI to begin modem handshaking on receipt of a Progress message, instead of waiting… |
1.3.6.1.4.1.429.1.27.1.1.46 | usrds1CfgISSMode | 0 | 0 | This object enables or disables the ISS feature that allows message to be passed between an ISS enabled EdgeServer and Siemens EW… |