The minimum number of milliseconds that the dry contact sensor on Ext1
must read openbefore the state is changed from closed to open.
Parsed from file netbotz2.mib.txt
Company: None
Module: NETBOTZ-MIB
The minimum number of milliseconds that the dry contact sensor on Ext1
must read openbefore the state is changed from closed to open.
Parsed from file NETBOTZ-MIB.mib
Module: NETBOTZ-MIB
Vendor: NetBotz
Module: NETBOTZ-PRD-BOT-MIB
[Automatically extracted from oidview.com]
netBotz-prd-bot-ext-dry1-close-to-open-millis OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The minimum number of milliseconds that the dry contact sensor on Ext1 must read openbefore the state is changed from closed to open." REFERENCE "NetBotz Ext Dry 1 Closed-to-Open Millis" ::= { netBotz-prd-bot 128 }
netBotz-prd-bot-ext-dry1-close-to-open-millis OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The minimum number of milliseconds that the dry contact sensor on Ext1 must read openbefore the state is changed from closed to open." REFERENCE "NetBotz Ext Dry 1 Closed-to-Open Millis" ::= { netBotz-prd-bot 128 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.5528.30.10.128.0 | netBotz-prd-bot-ext-dry1-close-to-open-millis | 0 | 0 | None |
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.5528.30.10.78 | netBotz-prd-bot-ext-temp1-uV-per-degreeC | 1 | 1 | The scaling factor used for the external temperature probe on port 1 to convert microvolts measured from the temperature sensor … |
1.3.6.1.4.1.5528.30.10.79 | netBotz-prd-bot-ext-temp1-uV-at-0-degreeC | 1 | 1 | The offset used for the external temperature probe on port 1 of microvolts measured from the temperature sensor at zero degrees … |
1.3.6.1.4.1.5528.30.10.80 | netBotz-prd-bot-ext-temp1-min-range | 1 | 1 | The minimum temperature measureable by the temperature sensor installed on port 1, in tenths of a degree C. Needs to be set base… |
1.3.6.1.4.1.5528.30.10.81 | netBotz-prd-bot-ext-temp1-max-range | 1 | 1 | The maximum temperature measureable by the temperature sensor installed on port 1, in tenths of a degree C. Needs to be set base… |
1.3.6.1.4.1.5528.30.10.82 | netBotz-prd-bot-ext-temp2-uV-per-degreeC | 1 | 1 | The scaling factor used for the external temperature probe on port 2 to convert microvolts measured from the temperature sensor … |
1.3.6.1.4.1.5528.30.10.83 | netBotz-prd-bot-ext-temp2-uV-at-0-degreeC | 1 | 1 | The offset used for the external temperature probe on port 2 of microvolts measured from the temperature sensor at zero degrees … |
1.3.6.1.4.1.5528.30.10.84 | netBotz-prd-bot-ext-temp2-min-range | 1 | 1 | The minimum temperature measureable by the temperature sensor installed on port 2, in tenths of a degree C. Needs to be set base… |
1.3.6.1.4.1.5528.30.10.85 | netBotz-prd-bot-ext-temp2-max-range | 1 | 1 | The maximum temperature measureable by the temperature sensor installed on port 2, in tenths of a degree C. Needs to be set base… |
1.3.6.1.4.1.5528.30.10.86 | netBotz-prd-bot-ext-temp3-uV-per-degreeC | 1 | 1 | The scaling factor used for the external temperature probe on port 3 to convert microvolts measured from the temperature sensor … |
1.3.6.1.4.1.5528.30.10.87 | netBotz-prd-bot-ext-temp3-uV-at-0-degreeC | 1 | 1 | The offset used for the external temperature probe on port 3 of microvolts measured from the temperature sensor at zero degrees … |
1.3.6.1.4.1.5528.30.10.88 | netBotz-prd-bot-ext-temp3-min-range | 1 | 1 | The minimum temperature measureable by the temperature sensor installed on port 3, in tenths of a degree C. Needs to be set base… |
1.3.6.1.4.1.5528.30.10.89 | netBotz-prd-bot-ext-temp3-max-range | 1 | 1 | The maximum temperature measureable by the temperature sensor installed on port 3, in tenths of a degree C. Needs to be set base… |
1.3.6.1.4.1.5528.30.10.90 | netBotz-prd-bot-ext-temp4-uV-per-degreeC | 1 | 1 | The scaling factor used for the external temperature probe on port 4 to convert microvolts measured from the temperature sensor … |
1.3.6.1.4.1.5528.30.10.91 | netBotz-prd-bot-ext-temp4-uV-at-0-degreeC | 1 | 1 | The offset used for the external temperature probe on port 4 of microvolts measured from the temperature sensor at zero degrees … |
1.3.6.1.4.1.5528.30.10.92 | netBotz-prd-bot-ext-temp4-min-range | 1 | 1 | The minimum temperature measureable by the temperature sensor installed on port 4, in tenths of a degree C. Needs to be set base… |
1.3.6.1.4.1.5528.30.10.93 | netBotz-prd-bot-ext-temp4-max-range | 1 | 1 | The maximum temperature measureable by the temperature sensor installed on port 4, in tenths of a degree C. Needs to be set base… |
1.3.6.1.4.1.5528.30.10.94 | netBotz-prd-bot-ext-port1-module-id | 1 | 1 | The module ID of the sensor module installed on port 1. Blank string indicates that no module is installed. |
1.3.6.1.4.1.5528.30.10.95 | netBotz-prd-bot-ext-port1-module-type | 1 | 1 | The type of sensor module installed on port 1. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact … |
1.3.6.1.4.1.5528.30.10.96 | netBotz-prd-bot-ext-port2-module-id | 1 | 1 | The module ID of the sensor module installed on port 2. Blank string indicates that no module is installed. |
1.3.6.1.4.1.5528.30.10.97 | netBotz-prd-bot-ext-port2-module-type | 1 | 1 | The type of sensor module installed on port 2. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact … |
1.3.6.1.4.1.5528.30.10.98 | netBotz-prd-bot-ext-port3-module-id | 1 | 1 | The module ID of the sensor module installed on port 3. Blank string indicates that no module is installed. |
1.3.6.1.4.1.5528.30.10.99 | netBotz-prd-bot-ext-port3-module-type | 1 | 1 | The type of sensor module installed on port 3. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact … |
1.3.6.1.4.1.5528.30.10.100 | netBotz-prd-bot-ext-port4-module-id | 1 | 1 | The module ID of the sensor module installed on port 4. Blank string indicates that no module is installed. |
1.3.6.1.4.1.5528.30.10.101 | netBotz-prd-bot-ext-port4-module-type | 1 | 1 | The type of sensor module installed on port 4. NONE=no module, AMP=AmpDetect module, TEMP=temperature sensor, DRY=dry contact … |
1.3.6.1.4.1.5528.30.10.102 | netBotz-prd-bot-amp1-total-amp-seconds | 1 | 1 | The accumulated total of amp-seconds on the AmpDetect on port 1. |
1.3.6.1.4.1.5528.30.10.103 | netBotz-prd-bot-amp1-total-amp-seconds-since-time | 1 | 1 | The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 1. Writi… |
1.3.6.1.4.1.5528.30.10.104 | netBotz-prd-bot-amp2-total-amp-seconds | 1 | 1 | The accumulated total of amp-seconds on the AmpDetect on port 2. |
1.3.6.1.4.1.5528.30.10.105 | netBotz-prd-bot-amp2-total-amp-seconds-since-time | 1 | 1 | The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 2. Writi… |
1.3.6.1.4.1.5528.30.10.106 | netBotz-prd-bot-amp3-total-amp-seconds | 1 | 1 | The accumulated total of amp-seconds on the AmpDetect on port 3. |
1.3.6.1.4.1.5528.30.10.107 | netBotz-prd-bot-amp3-total-amp-seconds-since-time | 1 | 1 | The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 3. Writi… |
1.3.6.1.4.1.5528.30.10.108 | netBotz-prd-bot-amp4-total-amp-seconds | 1 | 1 | The accumulated total of amp-seconds on the AmpDetect on port 4. |
1.3.6.1.4.1.5528.30.10.109 | netBotz-prd-bot-amp4-total-amp-seconds-since-time | 1 | 1 | The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds on the AmpDetect on port 4. Writi… |
1.3.6.1.4.1.5528.30.10.110 | netBotz-prd-bot-amptotal-total-amp-seconds | 1 | 1 | The accumulated total of amp-seconds on the total of all AmpDetects. |
1.3.6.1.4.1.5528.30.10.111 | netBotz-prd-bot-amptotal-total-amp-seconds-since-time | 1 | 1 | The UTC time (seconds since 1/1/1970) of the beginning of the accumulated total of amp-seconds for all AmpDetects. Writing a val… |
1.3.6.1.4.1.5528.30.10.112 | netBotz-prd-bot-ext-dry1 | 1 | 1 | The current value of the external dry contact sensor on Ext1: 0=Open, 1=Closed, -1=N/A |
1.3.6.1.4.1.5528.30.10.113 | netBotz-prd-bot-ext-dry2 | 1 | 1 | The current value of the external dry contact sensor on Ext2: 0=Open, 1=Closed, -1=N/A |
1.3.6.1.4.1.5528.30.10.114 | netBotz-prd-bot-ext-dry3 | 1 | 1 | The current value of the external dry contact sensor on Ext3: 0=Open, 1=Closed, -1=N/A |
1.3.6.1.4.1.5528.30.10.115 | netBotz-prd-bot-ext-dry4 | 1 | 1 | The current value of the external dry contact sensor on Ext4: 0=Open, 1=Closed, -1=N/A |
1.3.6.1.4.1.5528.30.10.116 | netBotz-prd-bot-ext-dry1-alarm-value | 1 | 1 | The value to generate alarms on for the external dry contact sensor on Ext1: 0=Open, 1=Closed |
1.3.6.1.4.1.5528.30.10.117 | netBotz-prd-bot-ext-dry1-enabled | 1 | 1 | External dry contact sensor on Ext1 alarm enabled(1) or disabled(0). |
1.3.6.1.4.1.5528.30.10.118 | netBotz-prd-bot-ext-dry2-alarm-value | 1 | 1 | The value to generate alarms on for the external dry contact sensor on Ext2: 0=Open, 1=Closed |
1.3.6.1.4.1.5528.30.10.119 | netBotz-prd-bot-ext-dry2-enabled | 1 | 1 | External dry contact sensor on Ext2 alarm enabled(1) or disabled(0). |
1.3.6.1.4.1.5528.30.10.120 | netBotz-prd-bot-ext-dry3-alarm-value | 1 | 1 | The value to generate alarms on for the external dry contact sensor on Ext3: 0=Open, 1=Closed |
1.3.6.1.4.1.5528.30.10.121 | netBotz-prd-bot-ext-dry3-enabled | 1 | 1 | External dry contact sensor on Ext3 alarm enabled(1) or disabled(0). |
1.3.6.1.4.1.5528.30.10.122 | netBotz-prd-bot-ext-dry4-alarm-value | 1 | 1 | The value to generate alarms on for the external dry contact sensor on Ext4: 0=Open, 1=Closed |
1.3.6.1.4.1.5528.30.10.123 | netBotz-prd-bot-ext-dry4-enabled | 1 | 1 | External dry contact sensor on Ext4 alarm enabled(1) or disabled(0). |
1.3.6.1.4.1.5528.30.10.124 | netBotz-prd-bot-ext-dry1-label | 1 | 1 | The sensor name/label for the dry contact sensor on Ext1 |
1.3.6.1.4.1.5528.30.10.125 | netBotz-prd-bot-ext-dry1-open-label | 1 | 1 | The sensor name/label for the open(0) state for the dry contact sensor on Ext1 |
1.3.6.1.4.1.5528.30.10.126 | netBotz-prd-bot-ext-dry1-closed-label | 1 | 1 | The sensor name/label for the closed(0) state for the dry contact sensor on Ext1 |
1.3.6.1.4.1.5528.30.10.127 | netBotz-prd-bot-ext-dry1-open-to-close-millis | 1 | 1 | The minimum number of milliseconds that the dry contact sensor on Ext1 must read closed before the state is changed from open to… |
1.3.6.1.4.1.5528.30.10.129 | netBotz-prd-bot-ext-dry1-response | 1 | 1 | The type of alert response for the dry contact sensor on Ext1: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from c… |
1.3.6.1.4.1.5528.30.10.130 | netBotz-prd-bot-ext-dry2-label | 1 | 1 | The sensor name/label for the dry contact sensor on Ext2 |
1.3.6.1.4.1.5528.30.10.131 | netBotz-prd-bot-ext-dry2-open-label | 1 | 1 | The sensor name/label for the open(0) state for the dry contact sensor on Ext2 |
1.3.6.1.4.1.5528.30.10.132 | netBotz-prd-bot-ext-dry2-closed-label | 1 | 1 | The sensor name/label for the closed(0) state for the dry contact sensor on Ext2 |
1.3.6.1.4.1.5528.30.10.133 | netBotz-prd-bot-ext-dry2-open-to-close-millis | 1 | 1 | The minimum number of milliseconds that the dry contact sensor on Ext2 must read closed before the state is changed from open to… |
1.3.6.1.4.1.5528.30.10.134 | netBotz-prd-bot-ext-dry2-close-to-open-millis | 1 | 1 | The minimum number of milliseconds that the dry contact sensor on Ext2 must read openbefore the state is changed from closed to … |
1.3.6.1.4.1.5528.30.10.135 | netBotz-prd-bot-ext-dry2-response | 1 | 1 | The type of alert response for the dry contact sensor on Ext2: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from c… |
1.3.6.1.4.1.5528.30.10.136 | netBotz-prd-bot-ext-dry3-label | 1 | 1 | The sensor name/label for the dry contact sensor on Ext3 |
1.3.6.1.4.1.5528.30.10.137 | netBotz-prd-bot-ext-dry3-open-label | 1 | 1 | The sensor name/label for the open(0) state for the dry contact sensor on Ext3 |
1.3.6.1.4.1.5528.30.10.138 | netBotz-prd-bot-ext-dry3-closed-label | 1 | 1 | The sensor name/label for the closed(0) state for the dry contact sensor on Ext3 |
1.3.6.1.4.1.5528.30.10.139 | netBotz-prd-bot-ext-dry3-open-to-close-millis | 1 | 1 | The minimum number of milliseconds that the dry contact sensor on Ext3 must read closed before the state is changed from open to… |
1.3.6.1.4.1.5528.30.10.140 | netBotz-prd-bot-ext-dry3-close-to-open-millis | 1 | 1 | The minimum number of milliseconds that the dry contact sensor on Ext3 must read openbefore the state is changed from closed to … |
1.3.6.1.4.1.5528.30.10.141 | netBotz-prd-bot-ext-dry3-response | 1 | 1 | The type of alert response for the dry contact sensor on Ext3: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from c… |
1.3.6.1.4.1.5528.30.10.142 | netBotz-prd-bot-ext-dry4-label | 1 | 1 | The sensor name/label for the dry contact sensor on Ext4 |
1.3.6.1.4.1.5528.30.10.143 | netBotz-prd-bot-ext-dry4-open-label | 1 | 1 | The sensor name/label for the open(0) state for the dry contact sensor on Ext4 |
1.3.6.1.4.1.5528.30.10.144 | netBotz-prd-bot-ext-dry4-closed-label | 1 | 1 | The sensor name/label for the closed(0) state for the dry contact sensor on Ext4 |
1.3.6.1.4.1.5528.30.10.145 | netBotz-prd-bot-ext-dry4-open-to-close-millis | 1 | 1 | The minimum number of milliseconds that the dry contact sensor on Ext4 must read closed before the state is changed from open to… |
1.3.6.1.4.1.5528.30.10.146 | netBotz-prd-bot-ext-dry4-close-to-open-millis | 1 | 1 | The minimum number of milliseconds that the dry contact sensor on Ext4 must read openbefore the state is changed from closed to … |
1.3.6.1.4.1.5528.30.10.147 | netBotz-prd-bot-ext-dry4-response | 1 | 1 | The type of alert response for the dry contact sensor on Ext4: ALERT=e-mail with no pictures, CAMERA=e-mail with pictures from c… |
1.3.6.1.4.1.5528.30.10.148 | netBotz-prd-bot-cam-motion | 1 | 1 | The current motion reading for the camera motion sensor (0=none, 1=motion detected) |
1.3.6.1.4.1.5528.30.10.149 | netBotz-prd-bot-cam-motion-enabled | 1 | 1 | Camera motion sensor alarm enabled(1) or disabled(0). |
1.3.6.1.4.1.5528.30.10.150 | netBotz-prd-bot-cam-motion-sensitivity | 1 | 1 | Camera motion sensor sensitivity: 1=max, 15=min, 0=disabled. |
1.3.6.1.4.1.5528.30.10.151 | netBotz-prd-bot-cam-motion-delay | 1 | 1 | Camera motion sensor delay. This is the minimum number of milliseconds of detected motion required before the alarm is triggere… |
1.3.6.1.4.1.5528.30.10.152 | netBotz-prd-bot-camera-event-autocycle | 1 | 1 | Enables (1) or disables (0) the option to have the camera-based responses to alarm conditions automatically cycle as long as the… |
1.3.6.1.4.1.5528.30.10.153 | netBotz-prd-bot-num-pix-before-alarm | 1 | 1 | Controls the number of pictures to be captured before any triggered alarm. |
1.3.6.1.4.1.5528.30.10.154 | netBotz-prd-bot-delay-before-event-pix | 1 | 1 | Controls the number of milliseconds before the first picture is captured after any triggered alarm. |
1.3.6.1.4.1.5528.30.10.155 | netBotz-prd-bot-delay-between-event-pix | 1 | 1 | Controls the number of milliseconds between pictures captured after any triggered alarm. |
1.3.6.1.4.1.5528.30.10.156 | netBotz-prd-bot-cam-motion-area-of-motion | 1 | 1 | Camera motion sensor area of motion: 1=max, 15=min, 0=disabled. |
1.3.6.1.4.1.5528.30.10.157 | netBotz-prd-bot-cam-pix-for-duration-of-alerts | 1 | 1 | Camera images gathered for duration of camera related alert: 0=no, 1=yes. |
1.3.6.1.4.1.5528.30.10.158 | netBotz-prd-bot-camera-enabled | 1 | 1 | Controls whether the camera is enabled or not: 0=no, 1=yes. Changing this will reboot the appliance. |
1.3.6.1.4.1.5528.30.10.159 | netBotz-prd-bot-camera-is-flipped | 1 | 1 | Controls whether the camera image is flipped 180 degress or not: 0=no, 1=yes. Changing this will reboot the appliance. |
1.3.6.1.4.1.5528.30.10.160 | netBotz-prd-bot-camera-brightness | 1 | 1 | Sets the brightness on the camera, from 20 to 180 (20 is low, 180 is high). |
... |