Reference record for OID 1.3.6.1.4.1.564.101.1.2.1


parent
1.3.6.1.4.1.564.101.1.2 (elCM)
node code
1
node name
elCMSystemStatus
dot oid
1.3.6.1.4.1.564.101.1.2.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) telco(564) edgeLink(101) elM13v1(1) elCM(2) elCMSystemStatus(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) telco(564) edgeLink(101) elM13v1(1) elCM(2) elCMSystemStatus(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) telco(564) edgeLink(101) elM13v1(1) elCM(2) elCMSystemStatus(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) telco(564) edgeLink(101) elM13v1(1) elCM(2) elCMSystemStatus(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) telco(564) edgeLink(101) elM13v1(1) elCM(2) elCMSystemStatus(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) telco(564) edgeLink(101) elM13v1(1) elCM(2) elCMSystemStatus(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/telco/edgeLink/elM13v1/elCM/elCMSystemStatus
  • /iso/identified-organization/dod/internet/private/enterprises/telco/edgeLink/elM13v1/elCM/elCMSystemStatus
  • /iso/org/dod/internet/private/enterprise/telco/edgeLink/elM13v1/elCM/elCMSystemStatus
  • /iso/org/dod/internet/private/enterprises/telco/edgeLink/elM13v1/elCM/elCMSystemStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprise/telco/edgeLink/elM13v1/elCM/elCMSystemStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/telco/edgeLink/elM13v1/elCM/elCMSystemStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/564/101/1/2/1

    Description by mibdepot

    This DisplayString gives the summary information about
    the Current EdgeLink100 System Status. The Description
    includes ...

    1) chasisType
    2) Active Module
    3) Fault LED Status
    4) Abnormal LED Status

    Fault LED Status is a combined value of the three bits
    each representing CRITICAL, MAJOR and MINOR Alarms. The
    three LEDS are inside the EL100 Case on the Cards.
    0 => No Alarms.
    1 => Critical Alarm (001)
    2 => Major Alarm (010)
    3 => Critical and Major Alarms (011)
    4 => Minor Alarm (100)
    5 => Minor and Critical Alarms (101)
    6 => Minor and Major Alarms (110)
    7 => Major Minor and Critical Alarms (111).

    Parsed from file el.mib.txt
    Company: None
    Module: EDGELINK-MIB

    Description by circitor

    This DisplayString gives the summary information about
    the Current EdgeLink100 System Status. The Description
    includes ...

    1) chasisType
    2) Active Module
    3) Fault LED Status
    4) Abnormal LED Status

    Fault LED Status is a combined value of the three bits
    each representing CRITICAL, MAJOR and MINOR Alarms. The
    three LEDS are inside the EL100 Case on the Cards.
    0 => No Alarms.
    1 => Critical Alarm (001)
    2 => Major Alarm (010)
    3 => Critical and Major Alarms (011)
    4 => Minor Alarm (100)
    5 => Minor and Critical Alarms (101)
    6 => Minor and Major Alarms (110)
    7 => Major Minor and Critical Alarms (111).

    Parsed from file EDGELINK-MIB.mib
    Module: EDGELINK-MIB

    Information by oid_info

    Vendor: Telco Systems NAC
    Module: EDGELINK-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    elCMSystemStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This DisplayString gives the summary information about the Current EdgeLink100 System Status. The Description includes ... 1) chasisType 2) Active Module 3) Fault LED Status 4) Abnormal LED Status Fault LED Status is a combined value of the three bits each representing CRITICAL, MAJOR and MINOR Alarms. The three LEDS are inside the EL100 Case on the Cards. 0 => No Alarms. 1 => Critical Alarm (001) 2 => Major Alarm (010) 3 => Critical and Major Alarms (011) 4 => Minor Alarm (100) 5 => Minor and Critical Alarms (101) 6 => Minor and Major Alarms (110) 7 => Major Minor and Critical Alarms (111). " ::= { elCM 1 }

    Information by circitor

    elCMSystemStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This DisplayString gives the summary information about the Current EdgeLink100 System Status. The Description includes ... 1) chasisType 2) Active Module 3) Fault LED Status 4) Abnormal LED Status Fault LED Status is a combined value of the three bits each representing CRITICAL, MAJOR and MINOR Alarms. The three LEDS are inside the EL100 Case on the Cards. 0 => No Alarms. 1 => Critical Alarm (001) 2 => Major Alarm (010) 3 => Critical and Major Alarms (011) 4 => Minor Alarm (100) 5 => Minor and Critical Alarms (101) 6 => Minor and Major Alarms (110) 7 => Major Minor and Critical Alarms (111). " ::= { elCM 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.564)

    Hirani Harry

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.564.101.1.2.1.0 elCMSystemStatus 0 0 None

    Brothers (12)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.564.101.1.2.2 elCMDS3ParityMode 1 1 Select C-bit or P-bit parity mode for DS3 interface.
    This Object can't be set when ServiceMode is IN-Service
    1.3.6.1.4.1.564.101.1.2.3 elCMDS3LineBuildout 1 1 Select line build-out for DS3 Line, 0 to 100 ft,
    100 to 200 ft, or 200-450.This MIB Object can't be set
    when ServiceMode is IN-Se…
    1.3.6.1.4.1.564.101.1.2.4 elCMDS3TxTiming 1 1 Select mode for DS3 transmit timing. This MIB Object
    can't be set when ServiceMode is IN-Service
    1.3.6.1.4.1.564.101.1.2.5 elCMProtectionMode 1 1 In unprotected mode, switching is prohibited.

    While in protected mode, a standing minor alarm will
    occur if the off-line card is …
    1.3.6.1.4.1.564.101.1.2.6 elCMCardSelect 1 1 Read or select choice of on-line card. This operation
    will force a switch to occur if the off-line card is
    selected.
    1.3.6.1.4.1.564.101.1.2.7 elCMClearTooManySwitches 1 1 Clear switching-disabled state which occurs as
    a result of too many switches between the cards in a
    protected system in a 10 minu…
    1.3.6.1.4.1.564.101.1.2.8 elCMDS3LoopbackMode 1 1 Set the DS3 loopback mode to line, terminal,
    remote, or none. The System can't be set to
    ds3LpbkRemoteFacility when it is in M13 …
    1.3.6.1.4.1.564.101.1.2.9 elCMDS3ServiceMode 1 1 Set the DS3 service mode to in-service or
    out-of-service. Certain service effecting operations
    can not be initiated unless the DS…
    1.3.6.1.4.1.564.101.1.2.10 elCMCurTimeDate 1 1 Read or set the system real time clock. The string
    is in the form MM/DD/YYYY HH:MM:SS.
    1.3.6.1.4.1.564.101.1.2.11 elCMBerThreshold 1 1 Set the BER Threshold value for the system to 10-6,
    10-7, 10-8 or 10-9. BerThershold can't changed when
    the ServiceMode is IN-Ser…
    1.3.6.1.4.1.564.101.1.2.12 elCMSystemInfo 1 1 Gets information about the MPU type, board revision,
    card revision level, software revision, CLEI code,
    MAC address, and Date of …
    1.3.6.1.4.1.564.101.1.2.13 elCMPPPPortBaudRate 1 1 Specifies the baud rate on the craft/PPP port when
    that port is running PPP (i.e. when carrier detect is asserted).