Status in source: current.
Names: mltTestGr909HazardousPotentialTestResult
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mltTestGr909HazardousPotentialTestResult",
"OBJECT-TYPE",
"SYNTAX",
"MltTestPassFail",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.\"",
"::=",
"{",
"mltTestResultsEntry",
"26",
"}"
],
"syntax_tree": [
[
"row",
"MltTestPassFail"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only."
],
null,
null,
null,
null
]
}