Status in source: current.
Names: mltTestGr909RingerTestRen
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mltTestGr909RingerTestRen",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"UNITS",
[
"literal",
"22302e312052454e22"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.\"",
"::=",
"{",
"mltTestResultsEntry",
"36",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
[
"UNITS",
"0.1 REN"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only."
],
null,
null,
null,
null
]
}