Status in source: current.
Names: mltTestGr909ReceiverOffhookTestDifference
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mltTestGr909ReceiverOffhookTestDifference",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"UNITS",
[
"literal",
"222522"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. \"",
"::=",
"{",
"mltTestResultsEntry",
"34",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
[
"UNITS",
"%"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only."
],
null,
null,
null,
null
]
}