The tmnxSonetSectionTraceMode variable along with the
tmnxSonetJ0String object determines the contents of
the section trace bytes (j0/z0) in the SONET Section Header. If the
mode is set to 'increment-z0', then the j0 byte is 0x01, and the
z0 byte increments. If the mode is set to 'byte', then the j0 byte is
the first octet of the tmnxSonetJ0String object and the z0 byte
is 0xcc. If the mode is set to 'string', then the J0 byte is set to
the 16 values in the tmnxSonetJ0String object and the z0 byte is
0xcc.
Parsed from file TIMETRA-PORT-MIB.mib
Module: TIMETRA-PORT-MIB
tmnxSonetSectionTraceMode OBJECT-TYPE SYNTAX INTEGER { increment-z0(1), byte(2), string(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The tmnxSonetSectionTraceMode variable along with the tmnxSonetJ0String object determines the contents of the section trace bytes (j0/z0) in the SONET Section Header. If the mode is set to 'increment-z0', then the j0 byte is 0x01, and the z0 byte increments. If the mode is set to 'byte', then the j0 byte is the first octet of the tmnxSonetJ0String object and the z0 byte is 0xcc. If the mode is set to 'string', then the J0 byte is set to the 16 values in the tmnxSonetJ0String object and the z0 byte is 0xcc." DEFVAL { byte } ::= { tmnxSonetEntry 18 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.1 | tmnxSonetSpeed | 0 | 0 | The rate of this optical facility. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.2 | tmnxSonetClockSource | 0 | 0 | tmnxSonetClockSource configures the clock for transmitted data from either the internal clock ('nodeTimed') or from a clock reco… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.3 | tmnxSonetFraming | 0 | 0 | The value of tmnxSonetFraming indicates the type of framing used on this interface. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.4 | tmnxSonetReportAlarm | 0 | 0 | The value of tmnxSonetReportAlarm determines when and if to generate tmnxEqPortSonetAlarm and tmnxEqPortSonetAlarmClear notificat… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.5 | tmnxSonetBerSdThreshold | 0 | 0 | The value of tmnxSonetBerSdThreshold specifies a bit error rate (BER) threshold used to determine when to send a tmnxEqPortSonet… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.6 | tmnxSonetBerSfThreshold | 0 | 0 | The value of tmnxSonetBerSfThreshold specifies a bit error rate (BER) threshold used to determine when to send a tmnxEqPortSonet… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.7 | tmnxSonetAps | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.8 | tmnxSonetApsAdminStatus | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.9 | tmnxSonetApsOperStatus | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.10 | tmnxSonetApsAuthKey | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.11 | tmnxSonetApsNeighborAddr | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.12 | tmnxSonetApsAdvertiseInterval | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.13 | tmnxSonetApsAdvertiseTimeLeft | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.14 | tmnxSonetApsHoldTime | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.15 | tmnxSonetApsHoldTimeLeft | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.16 | tmnxSonetLoopback | 0 | 0 | Activate a loopback on the SONET port. The SONET port must be in a shutdown state to activate any type of loopback. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.17 | tmnxSonetReportAlarmStatus | 0 | 0 | The bits in this object are used for indicating the alarms. The bits are explained as follows: loc(1) Indicates a loss of cl… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.19 | tmnxSonetJ0String | 0 | 0 | The tmnxSonetJ0String is used with the tmnxSonetSectionTraceMode variable to determine the contents of the j0 byte in the SONET … |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.20 | tmnxSonetMonS1Byte | 0 | 0 | The tmnxSonetMonS1Byte variable reports the Synchronization Status Message from the S1 byte in the Line Overhead Header. A value… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.21 | tmnxSonetMonJ0String | 0 | 0 | The tmnxSonetMonJ0String variable reports the contents of the j0 byte in the SONET Section Header. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.22 | tmnxSonetMonK1Byte | 0 | 0 | The tmnxSonetMonK1Byte variable reports the Automatic Protection Switching(APS) signalling status from the K1 byte in the SONET L… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.23 | tmnxSonetMonK2Byte | 0 | 0 | The tmnxSonetMonK1Byte variable reports the Automatic Protection Switching(APS) signalling status from the K2 byte in the SONET L… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.24 | tmnxSonetSingleFiber | 0 | 0 | tmnxSonetSingleFiber is used to enable/disable packet gathering and redirection of IP packets from a single fiber on RX port of … |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.25 | tmnxSonetHoldTimeUp | 0 | 0 | The value of tmnxSonetHoldTimeUp is used to configure the hold-timer for link up event dampening. This guards against reporting e… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.26 | tmnxSonetHoldTimeDown | 0 | 0 | The value of tmnxSonetHoldTimeDown is used to configure the hold-timer for link down event dampening. This guards against reporti… |