The value of tmnxSonetReportAlarm determines when and if to
generate tmnxEqPortSonetAlarm and tmnxEqPortSonetAlarmClear
notifications for this port:
loc(1) Reports a loss of clock which causes the operational
state of the port to be downed. Set by default.
lais(2) Reports line alarm indication signal errors. Not set
by default.
lrdi(3) Reports line remote defect initiation errors. LRDIs
are caused by remote LOF, LOC, and LOS. Set by default.
ss1f(4) Reports section synchronization failure as reported by
the S1 byte. Not set by default.
sb1err(5) Reports section B1 errors. Not set by default.
lb2erSd(6) Reports line signal degradation BER errors. Not set
by default.
lb2erSf(7) Reports line signal failure BER errors. Set by default.
slof(8) Reports section loss of frame errors. Set by default
slos(9) Reports section loss of signal errors. Set by default.
stxptr(10) Reports a section synchronization error on the transmit
side. Indicates if there is a positive or negative
justification count per channel. Not set by default.
srxptr(11) Reports a section synchronization error on the receive
side. Indicates if there is a positive or negative
justification count per path. Not set by default.
lrei(12) Reports a line error condition raised by the remote
as a result of B1 errors received from this node.
Not set by default.
Parsed from file TIMETRA-PORT-MIB.mib
Module: TIMETRA-PORT-MIB
tmnxSonetReportAlarm OBJECT-TYPE SYNTAX BITS { notUsed (0), loc(1), lais(2), lrdi(3), ss1f(4), sb1err(5), lb2erSd(6), lb2erSf(7), slof(8), slos(9), stxptr(10), srxptr(11), lrei(12) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of tmnxSonetReportAlarm determines when and if to generate tmnxEqPortSonetAlarm and tmnxEqPortSonetAlarmClear notifications for this port: loc(1) Reports a loss of clock which causes the operational state of the port to be downed. Set by default. lais(2) Reports line alarm indication signal errors. Not set by default. lrdi(3) Reports line remote defect initiation errors. LRDIs are caused by remote LOF, LOC, and LOS. Set by default. ss1f(4) Reports section synchronization failure as reported by the S1 byte. Not set by default. sb1err(5) Reports section B1 errors. Not set by default. lb2erSd(6) Reports line signal degradation BER errors. Not set by default. lb2erSf(7) Reports line signal failure BER errors. Set by default. slof(8) Reports section loss of frame errors. Set by default slos(9) Reports section loss of signal errors. Set by default. stxptr(10) Reports a section synchronization error on the transmit side. Indicates if there is a positive or negative justification count per channel. Not set by default. srxptr(11) Reports a section synchronization error on the receive side. Indicates if there is a positive or negative justification count per path. Not set by default. lrei(12) Reports a line error condition raised by the remote as a result of B1 errors received from this node. Not set by default. " DEFVAL { {loc, lrdi, lb2erSf, slof, slos} } ::= { tmnxSonetEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.1 | tmnxSonetSpeed | 0 | 0 | The rate of this optical facility. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.2 | tmnxSonetClockSource | 0 | 0 | tmnxSonetClockSource configures the clock for transmitted data from either the internal clock ('nodeTimed') or from a clock reco… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.3 | tmnxSonetFraming | 0 | 0 | The value of tmnxSonetFraming indicates the type of framing used on this interface. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.5 | tmnxSonetBerSdThreshold | 0 | 0 | The value of tmnxSonetBerSdThreshold specifies a bit error rate (BER) threshold used to determine when to send a tmnxEqPortSonet… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.6 | tmnxSonetBerSfThreshold | 0 | 0 | The value of tmnxSonetBerSfThreshold specifies a bit error rate (BER) threshold used to determine when to send a tmnxEqPortSonet… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.7 | tmnxSonetAps | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.8 | tmnxSonetApsAdminStatus | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.9 | tmnxSonetApsOperStatus | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.10 | tmnxSonetApsAuthKey | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.11 | tmnxSonetApsNeighborAddr | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.12 | tmnxSonetApsAdvertiseInterval | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.13 | tmnxSonetApsAdvertiseTimeLeft | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.14 | tmnxSonetApsHoldTime | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.15 | tmnxSonetApsHoldTimeLeft | 0 | 0 | Automatic Protection Switching (APS) is supported on 7x50 systems by the APS-MIB and TIMETRA-APS-MIB. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.16 | tmnxSonetLoopback | 0 | 0 | Activate a loopback on the SONET port. The SONET port must be in a shutdown state to activate any type of loopback. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.17 | tmnxSonetReportAlarmStatus | 0 | 0 | The bits in this object are used for indicating the alarms. The bits are explained as follows: loc(1) Indicates a loss of cl… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.18 | tmnxSonetSectionTraceMode | 0 | 0 | The tmnxSonetSectionTraceMode variable along with the tmnxSonetJ0String object determines the contents of the section trace bytes… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.19 | tmnxSonetJ0String | 0 | 0 | The tmnxSonetJ0String is used with the tmnxSonetSectionTraceMode variable to determine the contents of the j0 byte in the SONET … |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.20 | tmnxSonetMonS1Byte | 0 | 0 | The tmnxSonetMonS1Byte variable reports the Synchronization Status Message from the S1 byte in the Line Overhead Header. A value… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.21 | tmnxSonetMonJ0String | 0 | 0 | The tmnxSonetMonJ0String variable reports the contents of the j0 byte in the SONET Section Header. |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.22 | tmnxSonetMonK1Byte | 0 | 0 | The tmnxSonetMonK1Byte variable reports the Automatic Protection Switching(APS) signalling status from the K1 byte in the SONET L… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.23 | tmnxSonetMonK2Byte | 0 | 0 | The tmnxSonetMonK1Byte variable reports the Automatic Protection Switching(APS) signalling status from the K2 byte in the SONET L… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.24 | tmnxSonetSingleFiber | 0 | 0 | tmnxSonetSingleFiber is used to enable/disable packet gathering and redirection of IP packets from a single fiber on RX port of … |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.25 | tmnxSonetHoldTimeUp | 0 | 0 | The value of tmnxSonetHoldTimeUp is used to configure the hold-timer for link up event dampening. This guards against reporting e… |
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.26 | tmnxSonetHoldTimeDown | 0 | 0 | The value of tmnxSonetHoldTimeDown is used to configure the hold-timer for link down event dampening. This guards against reporti… |