Description 1
Status of digital output 1
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.9839.2.1.1.119
Status of digital output 1
Identification
{1 3 6 1 4 1 9839 2 1 1 119}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.1.119.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
dout1 OBJECT-TYPE
SYNTAX Integer32 (0..1)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of digital output 1"
::= { digitalObjects 119 }on_off_boss OBJECT-TYPE
SYNTAX Integer32 (0..1)
UNITS "N/A"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Remote On/Off selection"
DEFVAL { 0 }
::= { digitalObjects 119 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Status of digital output 1
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Remote On/Off selection
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: dout1
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"dout1",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"1",
")",
"UNITS",
[
"literal",
"224e2f4122"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Status of digital output 1\"",
"::=",
"{",
"digitalObjects",
"119",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
1
]
]
]
],
[
"UNITS",
"N/A"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Status of digital output 1"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-fcp-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Status in source: current.
Names: on_off_boss
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"on_off_boss",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"1",
")",
"UNITS",
[
"literal",
"224e2f4122"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Remote On/Off selection\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"digitalObjects",
"119",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
1
]
]
]
],
[
"UNITS",
"N/A"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Remote On/Off selection"
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-insgrd-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9839.2.1.1.51 | alarmRHS, manual-reset-static-press-Alarm, glb-al, glb_al, all_ext_del, a1_e1, mal_maint_dev10, sel_rele_all_hf, cooling_heating, en_stampante, mal_oil_level, s_epromnook, a1_id, din107, def_ext_da | 0 | 0 | Alarm: Room Humidity Sensor Failed/Disconnected |
| 1.3.6.1.4.1.9839.2.1.1.52 | alarmCWOTS, enable-static-press-Warning, lead-comp, or-al-2lev, all_ext_ist, a1_e2, mal_maint_dev11, en_freecool, mal_low_pres, buzz_output, a2_hi, din108, anti_def_db | 0 | 0 | Alarm: Chilled Water Outlet T. Sensor Failed/Disconnected |
| 1.3.6.1.4.1.9839.2.1.1.53 | alarmC1Hours, manual-reset-static-press-Warning, wtrvlv-dir, range-t-ext, all_ha, a1_e3, mal_m_invdev1, cond_config, en_freeheat, mal_hp_transd, pro_pi, rele1_output, a2_lo, mall_term_klix1, end_def_de | 0 | 0 | ServiceAlarm: Compressor 1 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.54 | alarmC2Hours, enable-diff-press-Alarm, ups-on-alm, range-t-circ, all_hf, a1_ia, mal_broke_pr1, mal_serious, a2_ha, mall_term_klix2, sup_probe_a6 | 0 | 0 | ServiceAlarm: Compressor 2 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.55 | alarmC3Hours, manual-reset-diff-press-Alarm, pwrup-alm, range-t-man, all_sonda_amb, a1_da, mal_broke_pr2, ab_estate_inv_h6, en_compensazio, mal_fan1, si_sond_umid, a2_hf, mall_term_klix3, reset_alarm_p5 | 0 | 0 | ServiceAlarm: Compressor 3 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.56 | alarmC4Hours, enable-pressure-recovery, seetag-cust-alm1, range-t-ac, all_sonda_def, a1_ea, mal_broke_pr3, rotaz_compr_r5, inverter_steps, off_ventp_defr, mal_fan2, si_sond_acqua, a2_ed, mall_term_klix4, set_2_param_p6 | 0 | 0 | ServiceAlarm: Compressor 4 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.57 | alarmFilterHours, enable-Flow-Rate-Alarm, seetag-cust-alm2, umid-al, all_sonda_prod, a1_re, mal_pres_hpres, inverter, en_sbrin_cont, mal_pump_evap, si_sond_aria, mall_term_klix5, low_press_alarm_p7 | 0 | 0 | ServiceAlarm: Air Filter hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.58 | alarmHeat1Hours, manual-reset-Flow-Rate-Alarm, seetag-cust-alm3, range-u-amb, all_sonda_reg, a1_id, mal_pres_lpres, fc_valve_type, autostart, mal_master_offl, si_sond_acquain, mall_term_klix6 | 0 | 0 | ServiceAlarm: Heater 1 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.59 | alarmHeat2Hours, enable-Flow-Rate-recovery, seetag-cust-alm4, all_tem_min_s1, a2_hi, mal_block_dev1, not_fc_vlv_type, en_remoto, mal_unit2_offl, si_sond_ariain, mall_pres_h1 | 0 | 0 | ServiceAlarm: Heater 1 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.60 | alarmHumHours, enable-pCOWeb, shortcycle-alm-en, k-syson, mal_block_dev2, unloads_logic, mal_unit3_offl, bin_sta, mall_pres_h2, def_cmd | 0 | 0 | ServiceAlarm: Humidifier hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.61 | alarmUnitHours, fc-single-chiller, superv-off, xs-res-al, a2_ha, mal_block_dev3, valve4way_logic, mal_unit4_offl, si_rampap, mall_pres_h3 | 0 | 0 | ServiceAlarm: Unit hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.62 | alarmDI2, BMS-heartbeat, a2_hf, mal_block_dev4, mal_b1, es, mall_pres_h4 | 0 | 0 | Alarm by Digital Input 2 |
| 1.3.6.1.4.1.9839.2.1.1.63 | alarmDI4, sleep-mode, mal_block_dev5, mal_b2, si_comp_es, mall_pres_h5 | 0 | 0 | Alarm by Digital Input 4 |
| 1.3.6.1.4.1.9839.2.1.1.64 | alarmDI6, test-sm, a4_hc, mal_block_dev6, abil_rotaz, mal_b3, si_rampan, mall_pres_h6 | 0 | 0 | Alarm by Digital Input 6 |
| 1.3.6.1.4.1.9839.2.1.1.65 | alarmHum, ab-mediath, a4_pd, mal_block_dev7, sys_on, mal_b4, si_parz, mall_dif_olio1 | 0 | 0 | Humidifier General Alarm |
| 1.3.6.1.4.1.9839.2.1.1.66 | alarmGeneral, ustdby1-2, a4_bp, mal_block_dev8, mal_b5, si_rot2, mall_dif_olio2 | 0 | 0 | General Alarm |
| 1.3.6.1.4.1.9839.2.1.1.67 | alarm2ndLevel, emerg, mal_block_dev9, mal_b6, si_comp1_deu, mall_dif_olio3 | 0 | 0 | Standby Unit Switchover Alarm |
| 1.3.6.1.4.1.9839.2.1.1.68 | alarmA, mal_block_dev10, mal_b7, si_comp2_deu, mall_dif_olio4 | 0 | 0 | Type A Alarm |
| 1.3.6.1.4.1.9839.2.1.1.69 | alarmB, mal_block_dev11, mal_b8, mall_dif_olio5 | 0 | 0 | Type B Alarm |
| 1.3.6.1.4.1.9839.2.1.1.70 | alarmC, mal_high1, glb_al, mal_pump_cond_h, mall_dif_olio6 | 0 | 0 | Type C Alarm |
| 1.3.6.1.4.1.9839.2.1.1.71 | selDXCW, digital_out_2, mal_low1, man_freeze, mal_comp_hour, si_fasce, mall_ore_comp1 | 0 | 0 | DX/CW Switch on TC Units |
| 1.3.6.1.4.1.9839.2.1.1.72 | selSW, mal_high2, mal_ov1, mal_pump_cond, mall_ore_comp2 | 0 | 0 | Summer/Winter Switchover |
| 1.3.6.1.4.1.9839.2.1.1.73 | digital_out_4, mal_low2, mal_ov2, mal_clock32, syson, mall_ore_comp3 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.74 | mal_n_devices, mal_ov3, syson1, mal_phase, si_rampap3v, mall_ore_comp4 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.75 | systemOnOff, al-idrofrigo-pump-c-1, digital_out_6, mepromnook, mal_ov4, en_binati, mal_ld_transd, si_rampan3v, mall_ore_comp5 | 0 | 0 | System On-Off |
| 1.3.6.1.4.1.9839.2.1.1.76 | resetAlarm, al-idrofrigo-pump-c-2, digital_out_7, mal_clock, mal_cflow, en_sond_text, mal_voltage, manuale, mall_ore_comp6 | 0 | 0 | Alarm Reset |
| 1.3.6.1.4.1.9839.2.1.1.77 | resetHrsFilt, digital_out_8, syson, mal_eflow, en_sond_uext, mal_current, start_off, mall_term_vent1 | 0 | 0 | Filter Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.78 | resetHrC1, digital_out_9, mal_hp1, en_sond_def1, mal_pump_ev_h, mall_term_vent2 | 0 | 0 | Compressor 1 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.79 | resetHrC2, mal_hp2, en_sond_def2, mall_term_vent3 | 0 | 0 | Compressor 2 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.80 | resetHrC3, al-idrofrigo-fl-C, mal_od1, mal_disch_temp, alarm_e06, mall_term_vent4 | 0 | 0 | Compressor 3 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.81 | resetHrC4, mal_od2, mal_diff_pres, alarm_e08, mal_liquid_level | 0 | 0 | Compressor 4 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.82 | resetStC1, mal_lp1, mal_alco1_67_r, alarm_e09, mall_pres_lpres | 0 | 0 | Compressor 1 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.83 | resetStC2, mal_lp2, mal_alco1_68_r, alarm_e10, mall_pres_hpres | 0 | 0 | Compressor 2 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.84 | resetStC3, mal_hpt1, mal_alco1_69_r, alarm_e11, mal_low2 | 0 | 0 | Compressor 3 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.85 | resetStC4, mal_hpt2, mal_alco1_70_r, alarm_e12, mall_alta_mand | 0 | 0 | Compressor 4 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.86 | resetHrH1, mal_serious, tipo_cont, mal_alco1_71_r, mal_low_press | 0 | 0 | Heater 1 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.87 | resetHrH2, mal_f1_overload, mal_alco1_72_r, mal_high_press | 0 | 0 | Heater 2 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.88 | resetStH1, sl_alm_1, mal_f2_overload, mal_alco1_73_r, mal_n_input | 0 | 0 | Heater 1 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.89 | resetStH2, mal_f3_overload, mal_alco1_74_r, mal_n_devices | 0 | 0 | Heater 2 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.90 | resetHrHU, mal_fan, mal_alco1_75_r, mall_ora | 0 | 0 | Humidifier Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.91 | resetStHU, mal_cpump, mal_alco1_760_r, mal_broke_pr1 | 0 | 0 | Humidifier Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.92 | resetHrACU, mal_pump, mal_alco1_97_r, mal_broke_pr2 | 0 | 0 | Unit Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.93 | mal_unit1_offl, glb_al | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.94 | mal_unit2_offl | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.95 | sleepmode, sv_mst_defrost_end, mal_unit3_offl | 0 | 0 | Setback Mode (Sleep Mode) |
| 1.3.6.1.4.1.9839.2.1.1.96 | smtest, sv_mst_defrost_start, mal_unit4_offl | 0 | 0 | Sleep Mode Test |
| 1.3.6.1.4.1.9839.2.1.1.97 | enablemeanT, sw_door_brk, mal_b1 | 0 | 0 | Local/Mean Usage of Values |
| 1.3.6.1.4.1.9839.2.1.1.98 | mal_b2 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.99 | mal_b3 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.100 | c11-on, mal_b4 | 0 | 0 |